Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography

被引:28
|
作者
Elke, Gunnar [1 ]
Fuld, Matthew K. [2 ,3 ]
Halaweish, Ahmed F. [2 ,3 ]
Grychtol, Bartlomiej [4 ]
Weiler, Norbert [1 ]
Hoffman, Eric A. [2 ,3 ]
Frerichs, Inez [1 ]
机构
[1] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Univ Iowa, Dept Radiol, Carver Coll Med, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[4] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
关键词
EIT; multidetector-row computed tomography; regional ventilation; lung injury; xenon; EIT RECONSTRUCTION; TIDAL VOLUME; RECRUITMENT; COLLAPSE; MODELS;
D O I
10.1088/0967-3334/34/10/1303
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Validation studies of electrical impedance tomography (EIT) based assessment of regional ventilation under pathological conditions are required to prove that EIT can reliably quantify heterogeneous ventilation distribution with sufficient accuracy. The objective of our study was to validate EIT measurements of regional ventilation through a comparison with xenon-multidetector-row computed tomography (XeCT) in an animal model of sub-lobar lung injury. Nine anesthetized mechanically ventilated supine pigs were examined before and after the induction of lung injury in two adjacent sub-lobar segments of the right lung by saline lavage or endotoxin instillation. Regional ventilation was determined in 32 anteroposterior regions of interest in the right and left lungs and the ventilation change quantified by difference images between injury and control. Six animals were included in the final analysis. Measurements of regional ventilation by EIT and XeCT correlated well before (r(s) = 0.89 right, r(s) = 0.90 left lung) and after local injury (r(s) = 0.79 and 0.92, respectively). No bias and narrow limits of agreement were found during both conditions. The ventilation decrease in the right injured lung was correspondingly measured by both modalities (5.5%+/-1.1% by EIT and 5.4%+/-1.9% by XeCT, p = 0.94). EIT was inferior to clearly separate the exact anatomical location of the regional injuries. Regional ventilation was overestimated (<2%) in the most ventral and dorsal regions and underestimated (2%) in the middle regions by EIT compared to XeCT. This study shows that EIT is able to reliably discern even small ventilation changes on sub-lobar level.
引用
收藏
页码:1303 / 1318
页数:16
相关论文
共 50 条
  • [31] The acute effects of postural change and non-invasive ventilation breathing on the regional distribution of lung ventilation: An electrical impedance tomography study
    de Sousa, Nathalia Parente
    Marinho, Liegina Silveira
    Monteiro, Luana Torres
    Sampaio, Aline Menezes
    Diogenes Bastos, Vasco Pinheiro
    Cirino Nogueira, Andrea da Nobrega
    Alves-de-Almeida, Mirizana
    Vieira Costa, Eduardo Leite
    Beraldo, Marcelo do Amaral
    Passos Amato, Marcelo Britto
    Holanda, Marcelo Alcantara
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [32] Assessment of distribution of ventilation and regional lung compliance by electrical impedance tomography in anaesthetized horses undergoing alveolar recruitment manoeuvres
    Ambrisko, Tamas D.
    Schramel, Johannes
    Hopster, Klaus
    Kaestner, Sabine
    Moens, Yves
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (02) : 264 - 272
  • [33] Lung Ventilation Functional Monitoring Based on Electrical Impedance Tomography
    陈晓艳
    王化祥
    赵波
    石小累
    Transactions of Tianjin University, 2009, 15 (01) : 7 - 12
  • [34] Lung Ventilation Functional Monitoring Based on Electrical Impedance Tomography
    陈晓艳
    王化祥
    赵波
    石小累
    Transactions of Tianjin University, 2009, (01) : 7 - 12
  • [35] Feature Extraction of Lung Ventilation by Biomedical Electrical Impedance Tomography
    Chen, Xiaoyan
    Chang, Xiaomin
    2017 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2017, : 558 - 562
  • [36] Lung ventilation functional monitoring based on electrical impedance tomography
    Chen X.
    Wang H.
    Zhao B.
    Shi X.
    Transactions of Tianjin University, 2009, 15 (1) : 7 - 12
  • [37] Electrical impedance tomography in monitoring experimental lung injury
    I. Frerichs
    G. Hahn
    T. Schröder
    G. Heilige
    Intensive Care Medicine, 1998, 24 : 829 - 836
  • [38] Electrical impedance tomography in monitoring experimental lung injury
    Frerichs, I
    Hahn, G
    Schroder, T
    Hellige, G
    INTENSIVE CARE MEDICINE, 1998, 24 (08) : 829 - 836
  • [39] DYNAMIC COMPUTED-TOMOGRAPHY OF THE LUNG - REGIONAL VENTILATION MEASUREMENTS
    GUR, D
    DRAYER, BP
    BOROVETZ, HS
    GRIFFITH, BP
    HARDESTY, RL
    WOLFSON, SK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (06) : 749 - 753
  • [40] Regional Ventilation-Perfusion Matching by Electrical Impedance Tomography After Single Lung Transplant
    Scaravilli, Vittorio
    Colombo, Sebastiano Maria
    Fumagalli, Jacopo
    Mauri, Tommaso
    Zanella, Alberto
    Rosso, Lorenzo
    Grasselli, Giacomo
    ASAIO JOURNAL, 2024, 70 (03) : e49 - e52