Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography

被引:28
作者
Elke, Gunnar [1 ]
Fuld, Matthew K. [2 ,3 ]
Halaweish, Ahmed F. [2 ,3 ]
Grychtol, Bartlomiej [4 ]
Weiler, Norbert [1 ]
Hoffman, Eric A. [2 ,3 ]
Frerichs, Inez [1 ]
机构
[1] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Univ Iowa, Dept Radiol, Carver Coll Med, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[4] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
关键词
EIT; multidetector-row computed tomography; regional ventilation; lung injury; xenon; EIT RECONSTRUCTION; TIDAL VOLUME; RECRUITMENT; COLLAPSE; MODELS;
D O I
10.1088/0967-3334/34/10/1303
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Validation studies of electrical impedance tomography (EIT) based assessment of regional ventilation under pathological conditions are required to prove that EIT can reliably quantify heterogeneous ventilation distribution with sufficient accuracy. The objective of our study was to validate EIT measurements of regional ventilation through a comparison with xenon-multidetector-row computed tomography (XeCT) in an animal model of sub-lobar lung injury. Nine anesthetized mechanically ventilated supine pigs were examined before and after the induction of lung injury in two adjacent sub-lobar segments of the right lung by saline lavage or endotoxin instillation. Regional ventilation was determined in 32 anteroposterior regions of interest in the right and left lungs and the ventilation change quantified by difference images between injury and control. Six animals were included in the final analysis. Measurements of regional ventilation by EIT and XeCT correlated well before (r(s) = 0.89 right, r(s) = 0.90 left lung) and after local injury (r(s) = 0.79 and 0.92, respectively). No bias and narrow limits of agreement were found during both conditions. The ventilation decrease in the right injured lung was correspondingly measured by both modalities (5.5%+/-1.1% by EIT and 5.4%+/-1.9% by XeCT, p = 0.94). EIT was inferior to clearly separate the exact anatomical location of the regional injuries. Regional ventilation was overestimated (<2%) in the most ventral and dorsal regions and underestimated (2%) in the middle regions by EIT compared to XeCT. This study shows that EIT is able to reliably discern even small ventilation changes on sub-lobar level.
引用
收藏
页码:1303 / 1318
页数:16
相关论文
共 46 条
  • [1] GREIT: a unified approach to 2D linear EIT reconstruction of lung images
    Adler, Andy
    Arnold, John H.
    Bayford, Richard
    Borsic, Andrea
    Brown, Brian
    Dixon, Paul
    Faes, Theo J. C.
    Frerichs, Inez
    Gagnon, Herve
    Gaerber, Yvo
    Grychtol, Bartlomiej
    Hahn, Guenter
    Lionheart, William R. B.
    Malik, Anjum
    Patterson, Robert P.
    Stocks, Janet
    Tizzard, Andrew
    Weiler, Norbert
    Wolf, Gerhard K.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (06) : S35 - S55
  • [2] QUANTIFICATION IN IMPEDANCE IMAGING
    BARBER, DC
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 : 45 - 56
  • [3] Principles of electrical impedance tomography and its clinical application
    Bodenstein, Marc
    David, Matthias
    Markstaller, Klaus
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (02) : 713 - 724
  • [4] Acute lung injury/acute respiratory distress syndrome pathophysiology: what we have learned from computed tomography scanning
    Caironi, Pietro
    Langer, Thomas
    Gattinoni, Luciano
    [J]. CURRENT OPINION IN CRITICAL CARE, 2008, 14 (01) : 64 - 69
  • [5] Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies
    Chon, D
    Simon, BA
    Beck, KC
    Shikata, H
    Saba, OI
    Won, CH
    Hoffman, EA
    [J]. RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2005, 148 (1-2) : 65 - 83
  • [6] Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements
    Chon, Deokiee
    Beck, Kenneth C.
    Simon, Brett A.
    Shikata, Hidenori
    Saba, Osama I.
    Hoffman, Eric A.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2007, 102 (04) : 1535 - 1544
  • [7] Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography
    Costa, Eduardo L. V.
    Borges, Joao Batista
    Melo, Alexandre
    Suarez-Sipmann, Fernando
    Toufen, Carlos, Jr.
    Bohm, Stephan H.
    Amato, Marcelo B. P.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (06) : 1132 - 1137
  • [8] Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre
    Dargaville, Peter A.
    Rimensberger, Peter C.
    Frerichs, Inez
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 (11) : 1953 - 1961
  • [9] Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation
    Frerichs, I.
    Schmitz, G.
    Pulletz, S.
    Schaedler, D.
    Zick, G.
    Scholz, J.
    Weiler, N.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S261 - S267
  • [10] Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure
    Frerichs, I
    Hahn, G
    Hellige, G
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) : 764 - 773