Dual-templates molecularly imprinted monolithic columns for the evaluation of serotonin and histamine in CEC

被引:38
作者
Zaidi, Shabi Abbas [1 ,2 ]
机构
[1] Kwangwoon Univ, Dept Chem, Seoul 139701, South Korea
[2] Kwangwoon Univ, Kwangwoon Acad Adv Studies, Seoul 139701, South Korea
关键词
CEC; Dual-templates; Histamine; Molecular imprinted polymers; Serotonin; CAPILLARY ELECTROCHROMATOGRAPHY; SEPARATION PERFORMANCE; RECOGNITION PROPERTIES; CHIRAL RECOGNITION; POLYMERS; PHASE; CHROMATOGRAPHY; SELECTIVITY; RECEPTOR; BINDING;
D O I
10.1002/elps.201200640
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To extend the application of molecularly imprinted polymers, the dual-templates molecularly imprinted monolithic columns were developed in a capillary format. Two templates serotonin and histamine were simultaneously imprinted using two different functional monomers such as methacrylic acid (MAA) and methylenesuccinic acid (MSA) in a mixture of ethylene glycol dimethacrylate (EDMA) as a cross-linker and AIBN as polymerization initiator dissolved in DMF as porogen. The resulting molecular imprinted polymers (MIPs) were characterized based on their performance in the CEC separation of two imprinted templates. The optimization parameters such as pH, ACN composition, and concentration of the eluent were varied to achieve best resolution and efficiency for CEC separation of templates with each MIP column. It was found that the MIP monolith column fabricated using MSA offered better resolution and separation efficiency compared to column fabricated with MAA. This work utilized the dual-templates imprinting approach successfully and broadens the scope of multi-templates imprinting capabilities in capillary format in CEC application.
引用
收藏
页码:1375 / 1382
页数:8
相关论文
共 41 条
[1]   Molecular imprinting science and technology: a survey of the literature for the years up to and including 2003 [J].
Alexander, C ;
Andersson, HS ;
Andersson, LI ;
Ansell, RJ ;
Kirsch, N ;
Nicholls, IA ;
O'Mahony, J ;
Whitcombe, MJ .
JOURNAL OF MOLECULAR RECOGNITION, 2006, 19 (02) :106-180
[2]   A novel high selective and sensitive para-nitrophenol voltammetric sensor, based on a molecularly imprinted polymer-carbon paste electrode [J].
Alizadeh, Taher ;
Ganjali, Mohammad Reza ;
Norouzi, Parviz ;
Zare, Mashallah ;
Zeraatkar, Ali .
TALANTA, 2009, 79 (05) :1197-1203
[3]   Some considerations concerning the composition of the mobile phase in capillary electrochromatography [J].
Banholczer, A ;
Pyell, U .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :363-374
[4]   Synthesis and Characterization of Imprinted Polymers for Radioactive Waste Reduction [J].
Bhaskarapillai, Anupkumar ;
Sevilimedu, Narasimhan V. ;
Sellergren, Boerje .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (08) :3730-3737
[5]   Preparation of molecularly imprinted polymers using nitroxide-mediated living radical polymerization [J].
Boonpangrak, Somchai ;
Whitcombe, Michael J. ;
Prachayasittikul, Virapong ;
Mosbach, Klaus ;
Ye, Lei .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (03) :349-354
[6]   Synthesis and application of an oxytetracycline imprinted polymer for the solid-phase extraction of tetracycline antibiotics [J].
Caro, E ;
Marcé, RM ;
Cormack, PAG ;
Sherrington, DC ;
Borrull, F .
ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) :81-86
[7]   Dynamics of capillary electrochromatography - Experimental study on the electrosmotic flow and conductance in open and packed capillaries [J].
Choudhary, G ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :161-183
[8]   Molecularly imprinted polymers: synthesis and characterisation [J].
Cormack, PAG ;
Elorza, AZ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01) :173-182
[9]   Systematic cross-selectivity study of the factors influencing template receptor interactions in molecularly imprinted nitrogen heterocycles [J].
Cummins, Wayne ;
Duggan, Patrick ;
McLoughlin, Peter .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (03) :372-380
[10]   SIMULTANEOUS DETERMINATION OF HISTAMINE AND SEROTONIN IN MAST-CELLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
EGGER, D ;
REISBACH, G ;
HULTNER, L .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (01) :103-107