Experimental Study on the Effect of Air-Doors Control Adjacent to the Fire Source on the Characteristics of Smoke Back-Layering

被引:1
|
作者
Wang, Haiyan [1 ]
Xu, Zuohui [1 ]
Wang, Lei [1 ]
Fan, Cheng [1 ]
Zhang, Yanwei [1 ]
机构
[1] China Univ Min & Technol Beijing, Beijing Key Lab Precise Min Intergrown Energy & Re, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
mine fire; smoke back-layering; air-door adjacent to the fire source; smoke control; LONGITUDINAL VENTILATION; CRITICAL VELOCITY; TUNNEL FIRES; EMERGENCY RESCUE; COAL; SYSTEMS; FLOW; GAS; SIMULATION;
D O I
10.3390/pr10122496
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Air-doors are important facilities for regulating the air flow in a mine ventilation network. It is of value to study the influence of air-doors, which are adjacent to a fire source on smoke back-layering in order to build a rational ventilation system. By regulating air-doors in a mine ventilation network test platform, two typical mine ventilation networks, with parallel branches and a diagonal branch, were constructed. During the study, into the closing degree of the air-doors adjacent to a fire source in a ventilation network with parallel branches, the back-layering length is up to 3.70 m when the ventilation velocity is 1.40 m/s. When the air-door on the return side of the adjacent branch is closed, the back-layering subsides within 1 min and the upstream temperature drops rapidly to normal. When the air-door is half closed, there is still a back-layering flow within 5 min. Smoke control, with the air-door is closed, is better than when the air-door is half closed. Based on this, tests into the influence of the closing position of air-doors, which are adjacent to a fire source, were carried out in a ventilation network with a diagonal branch. Results indicate that when the ventilation velocity is 1.70 m/s, the back-layering flow spreads to the diagonal branch, and the air flow velocity of both the adjacent branch and the diagonal branch increases. When closing the air-door on the return side of the adjacent branch, the back-layering rapidly subsided. The wind velocity on the intake side of the adjacent branch is stabilized after a rapid decrease, and the wind velocity of the diagonal branch is stabilized after a rapid increase. When closing the air-door on the intake side of the adjacent branch, the smoke from the diagonal branch spreads. Compared with closing the intake side air-door, closing the air-door on the return side of the adjacent branch is more effective in preventing back-layering. This work provides a reference for preventing back-layering and guiding the evacuation of people from the upstream of a fire source.
引用
收藏
页数:12
相关论文
共 24 条
  • [21] Experimental and modelling study on smoke retaining effect of air curtain jet in urban utility tunnel fire
    Hefei Institute of Technology, Anhui, Hefei
    238076, China
    不详
    230026, China
    不详
    102202, China
    Therm. Sci. Eng. Prog.,
  • [22] Experimental and modelling study on smoke retaining effect of air curtain jet in urban utility tunnel fire
    Cao, Biteng
    Liu, Hong
    Fan, Rui
    Ju, Xiaoyu
    Yang, Lizhong
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 57
  • [23] Experimental and numerical simulation on smoke control effect and key parameters of Push-pull air curtain in tunnel fire
    Ji, Jingwei
    Lu, Wen
    Li, Fuqing
    Cui, Xiaoting
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 121
  • [24] Experimental study of dust effect on frosting and frost melting characteristics of air source heat pump fin surface
    Zhang, Pengfei
    Wang, Zhihua
    Wang, Fenghao
    Ma, Longxia
    APPLIED THERMAL ENGINEERING, 2025, 268