Experimental Study on the Effect of Air-Doors Control Adjacent to the Fire Source on the Characteristics of Smoke Back-Layering

被引:1
|
作者
Wang, Haiyan [1 ]
Xu, Zuohui [1 ]
Wang, Lei [1 ]
Fan, Cheng [1 ]
Zhang, Yanwei [1 ]
机构
[1] China Univ Min & Technol Beijing, Beijing Key Lab Precise Min Intergrown Energy & Re, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
mine fire; smoke back-layering; air-door adjacent to the fire source; smoke control; LONGITUDINAL VENTILATION; CRITICAL VELOCITY; TUNNEL FIRES; EMERGENCY RESCUE; COAL; SYSTEMS; FLOW; GAS; SIMULATION;
D O I
10.3390/pr10122496
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Air-doors are important facilities for regulating the air flow in a mine ventilation network. It is of value to study the influence of air-doors, which are adjacent to a fire source on smoke back-layering in order to build a rational ventilation system. By regulating air-doors in a mine ventilation network test platform, two typical mine ventilation networks, with parallel branches and a diagonal branch, were constructed. During the study, into the closing degree of the air-doors adjacent to a fire source in a ventilation network with parallel branches, the back-layering length is up to 3.70 m when the ventilation velocity is 1.40 m/s. When the air-door on the return side of the adjacent branch is closed, the back-layering subsides within 1 min and the upstream temperature drops rapidly to normal. When the air-door is half closed, there is still a back-layering flow within 5 min. Smoke control, with the air-door is closed, is better than when the air-door is half closed. Based on this, tests into the influence of the closing position of air-doors, which are adjacent to a fire source, were carried out in a ventilation network with a diagonal branch. Results indicate that when the ventilation velocity is 1.70 m/s, the back-layering flow spreads to the diagonal branch, and the air flow velocity of both the adjacent branch and the diagonal branch increases. When closing the air-door on the return side of the adjacent branch, the back-layering rapidly subsided. The wind velocity on the intake side of the adjacent branch is stabilized after a rapid decrease, and the wind velocity of the diagonal branch is stabilized after a rapid increase. When closing the air-door on the intake side of the adjacent branch, the smoke from the diagonal branch spreads. Compared with closing the intake side air-door, closing the air-door on the return side of the adjacent branch is more effective in preventing back-layering. This work provides a reference for preventing back-layering and guiding the evacuation of people from the upstream of a fire source.
引用
收藏
页数:12
相关论文
共 24 条
  • [1] An experimental study on the transition velocity and smoke back-layering length induced by carriage fire in a ventilated tunnel
    Hu, Peng
    Zhang, Zhenyi
    Zhang, Xiaochun
    Tang, Fei
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 106
  • [2] Study on the smoke back-layering and critical ventilation in the road tunnel fire at high altitude
    Zhang, Shaogang
    Wang, Jinhui
    He, Kun
    Yao, Yongzheng
    Peng, Min
    FIRE AND MATERIALS, 2019, 43 (04) : 422 - 429
  • [3] Evaluating the smoke back-layering length and critical velocity in branched tunnel fire with sloped mainline: An experimental study
    Huang, Youbo
    Luo, Chengjia
    Liu, Xi
    Tang, Fei
    Dong, Bingyan
    Zhong, Hua
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 143
  • [4] Experimental investigation on the smoke back-layering length in a branched tunnel fire considering different longitudinal ventilations and fire locations
    Yang, Xiaolong
    Luo, Yueyang
    Li, Zhisheng
    Guo, Hanwen
    Zhang, Yuchun
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [5] An experimental investigation on blockage effect of metro train on the smoke back-layering in subway tunnel fires
    Zhang, Shaogang
    Cheng, Xudong
    Yao, Yongzheng
    Zhu, Kai
    Li, Kaiyuan
    Lu, Song
    Zhang, Ruifang
    Zhang, Heping
    APPLIED THERMAL ENGINEERING, 2016, 99 : 214 - 223
  • [6] Study on the double effect of the tunnel slope on the fire induced smoke back-layering distance in naturally ventilated inclined tunnels
    Sun, Jiayun
    Wang, Junheng
    Fang, Zheng
    Tang, Zhi
    Merci, Bart
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 143
  • [7] Experimental study of smoke back-layering length under coordinated ventilation in underground interconnected tunnel
    Ying, Houlin
    Xu, Zhisheng
    Yin, Yaolong
    Yu, Zihan
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2025, 159
  • [8] A simplified calculation method on the smoke back-layering length and inlet air velocity in a tilted tunnel fire without shaft
    Li, Jiaxin
    Li, Yanfeng
    Li, Junmei
    Tian, Wei
    INDOOR AND BUILT ENVIRONMENT, 2023, 32 (01) : 274 - 285
  • [9] An experimental study on smoke back-layering and critical velocity in tunnel fires with canyon cross wind
    Zhao, Wangda
    Ouyang, Richeng
    Ran, Qian
    Chen, Tao
    Xu, Zhisheng
    Zou, Mengzhen
    Fan, Chuangang
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2021, 209
  • [10] Thermal smoke back-layering flow length with ceiling extraction at upstream side of fire source in a longitudinal ventilated tunnel
    Tang, F.
    Li, L. J.
    Mei, F. Z.
    Dong, M. S.
    APPLIED THERMAL ENGINEERING, 2016, 106 : 125 - 130