Experimental Study on the Effect of Air-Doors Control Adjacent to the Fire Source on the Characteristics of Smoke Back-Layering

被引:1
作者
Wang, Haiyan [1 ]
Xu, Zuohui [1 ]
Wang, Lei [1 ]
Fan, Cheng [1 ]
Zhang, Yanwei [1 ]
机构
[1] China Univ Min & Technol Beijing, Beijing Key Lab Precise Min Intergrown Energy & Re, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
mine fire; smoke back-layering; air-door adjacent to the fire source; smoke control; LONGITUDINAL VENTILATION; CRITICAL VELOCITY; TUNNEL FIRES; EMERGENCY RESCUE; COAL; SYSTEMS; FLOW; GAS; SIMULATION;
D O I
10.3390/pr10122496
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Air-doors are important facilities for regulating the air flow in a mine ventilation network. It is of value to study the influence of air-doors, which are adjacent to a fire source on smoke back-layering in order to build a rational ventilation system. By regulating air-doors in a mine ventilation network test platform, two typical mine ventilation networks, with parallel branches and a diagonal branch, were constructed. During the study, into the closing degree of the air-doors adjacent to a fire source in a ventilation network with parallel branches, the back-layering length is up to 3.70 m when the ventilation velocity is 1.40 m/s. When the air-door on the return side of the adjacent branch is closed, the back-layering subsides within 1 min and the upstream temperature drops rapidly to normal. When the air-door is half closed, there is still a back-layering flow within 5 min. Smoke control, with the air-door is closed, is better than when the air-door is half closed. Based on this, tests into the influence of the closing position of air-doors, which are adjacent to a fire source, were carried out in a ventilation network with a diagonal branch. Results indicate that when the ventilation velocity is 1.70 m/s, the back-layering flow spreads to the diagonal branch, and the air flow velocity of both the adjacent branch and the diagonal branch increases. When closing the air-door on the return side of the adjacent branch, the back-layering rapidly subsided. The wind velocity on the intake side of the adjacent branch is stabilized after a rapid decrease, and the wind velocity of the diagonal branch is stabilized after a rapid increase. When closing the air-door on the intake side of the adjacent branch, the smoke from the diagonal branch spreads. Compared with closing the intake side air-door, closing the air-door on the return side of the adjacent branch is more effective in preventing back-layering. This work provides a reference for preventing back-layering and guiding the evacuation of people from the upstream of a fire source.
引用
收藏
页数:12
相关论文
共 30 条
  • [1] Smoke control in sloping tunnels
    Atkinson, GT
    Wu, Y
    [J]. FIRE SAFETY JOURNAL, 1996, 27 (04) : 335 - 341
  • [2] Fire safety investigation for road tunnel ventilation systems - An overview
    Barbato, Lorenzo
    Cascetta, Furio
    Musto, Marilena
    Rotondo, Giuseppe
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 43 : 253 - 265
  • [3] Smoke movement in tilted tunnel fires with longitudinal ventilation
    Chow, W. K.
    Gao, Y.
    Zhao, J. H.
    Dang, J. F.
    Chow, C. L.
    Miao, L.
    [J]. FIRE SAFETY JOURNAL, 2015, 75 : 14 - 22
  • [4] Driving force for preventing smoke backlayering in downhill tunnel fires using forced longitudinal ventilation
    Du, Tao
    Yang, Dong
    Ding, Yao
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 79 : 76 - 82
  • [5] Mine Fire Behavior under Different Ventilation Conditions: Real-Scale Tests and CFD Modeling
    Fernandez-Alaiz, Florencio
    Maria Castanon, Ana
    Gomez-Fernandez, Fernando
    Bascompta, Marc
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (10):
  • [6] Oxygen control mechanism in non-ventilation excavation based on the simultaneous mining of coal and gas
    Fu Ming-ming
    Zheng Qian
    He Shuai
    Yan Yiran
    Wang Xiaohui
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2019, 123 : 33 - 38
  • [7] [郝海清 Hao Haiqing], 2021, [中国矿业大学学报. 自然科学版, Journal of China University of Mining & Technology], V50, P716
  • [8] Studies on buoyancy-driven back-layering flow in tunnel fires
    Hu, L. H.
    Huo, R.
    Chow, W. K.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (08) : 1468 - 1483
  • [9] Study on the Stress Variation Law of Inclined Surrounding Rock Roadway under the Influence of Mining
    Jia, Qian
    Wu, Hai
    Ling, Tao
    Liu, Kai
    Peng, Weiwei
    Gao, Xu
    Zhao, Yanlin
    [J]. MINERALS, 2022, 12 (05)
  • [10] An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires
    Lee, SR
    Ryou, HS
    [J]. JOURNAL OF FIRE SCIENCES, 2005, 23 (02) : 119 - 138