Simultaneous bright- and black-blood whole-heart MRI for noncontrast enhanced coronary lumen and thrombus visualization

被引:41
作者
Ginami, Giulia [1 ]
Neji, Radhouene [1 ,2 ]
Phinikaridou, Alkystis [1 ]
Whitaker, John [1 ]
Botnar, Rene M. [1 ,3 ]
Prieto, Claudia [1 ,3 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
[2] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[3] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国工程与自然科学研究理事会;
关键词
whole-heart; bright-blood; black-blood; coronary MR angiography; SENSITIVE INVERSION-RECOVERY; NAVIGATED IMAGE-RECONSTRUCTION; MAGNETIC-RESONANCE ANGIOGRAPHY; HIGH-INTENSITY SIGNALS; RESPIRATORY MOTION; MYOCARDIAL-INFARCTION; PLAQUE; TIME; ACQUISITION; CONTRAST;
D O I
10.1002/mrm.26815
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a 3D whole-heart Bright-blood and black-blOOd phase SensiTive (BOOST) inversion recovery sequence for simultaneous noncontrast enhanced coronary lumen and thrombus/hemorrhage visualization. MethodsThe proposed sequence alternates the acquisition of two bright-blood datasets preceded by different preparatory pulses to obtain variations in blood/myocardium contrast, which then are combined in a phase-sensitive inversion recovery (PSIR)-like reconstruction to obtain a third, coregistered, black-blood dataset. The bright-blood datasets are used for both visualization of the coronary lumen and motion estimation, whereas the complementary black-blood dataset potentially allows for thrombus/hemorrhage visualization. Furthermore, integration with 2D image-based navigation enables 100% scan efficiency and predictable scan times. The proposed sequence was compared to conventional coronary MR angiography (CMRA) and PSIR sequences in a standardized phantom and in healthy subjects. Feasibility for thrombus depiction was tested ex vivo. ResultsWith BOOST, the coronary lumen is visualized with significantly higher (P<0.05) contrast-to-noise ratio and vessel sharpness when compared to conventional CMRA. Furthermore, BOOST showed effective blood signal suppression as well as feasibility for thrombus visualization ex vivo. ConclusionA new PSIR sequence for noncontrast enhanced simultaneous coronary lumen and thrombus/hemorrhage detection was developed. The sequence provided improved coronary lumen depiction and showed potential for thrombus visualization. Magn Reson Med 79:1460-1472, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
引用
收藏
页码:1460 / 1472
页数:13
相关论文
共 53 条
[1]   Phase-Sensitive Black-Blood Coronary Vessel Wall Imaging [J].
Abd-Emoniem, Khaled Z. ;
Weiss, Robert G. ;
Stuber, Matthias .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) :1021-1030
[2]   100% Efficient three-dimensional coronary MR angiography with two-dimensional beat-to-beat translational and bin-to-bin affine motion correction [J].
Aitken, Andrew P. ;
Henningsson, Markus ;
Botnar, Rene M. ;
Schaeffter, Tobias ;
Prieto, Claudia .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (03) :756-764
[3]   Fibrin-Targeted Magnetic Resonance Imaging Allows In Vivo Quantification of Thrombus Fibrin Content and Identifies Thrombi Amenable for Thrombolysis [J].
Andia, Marcelo E. ;
Saha, Prakash ;
Jenkins, Julia ;
Modarai, Bijan ;
Wiethoff, Andrea J. ;
Phinikaridou, Alkystis ;
Grover, Steven P. ;
Patel, Ashish S. ;
Schaeffter, Tobias ;
Smith, Alberto ;
Botnar, Rene M. .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2014, 34 (06) :1193-1198
[4]   STIR MR IMAGING OF THE ORBIT [J].
ATLAS, SW ;
GROSSMAN, RI ;
HACKNEY, DB ;
GOLDBERG, HI ;
BILANIUK, LT ;
ZIMMERMAN, RA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) :1025-1030
[5]   Molecular Imaging in Cardiovascular Diseases [J].
Botnar, R. M. ;
Ebersberger, H. ;
Noerenberg, D. ;
Jansen, C. H. P. ;
Wiethoff, A. J. ;
Schuster, A. ;
Kasner, M. ;
Walter, T. C. ;
Knobloch, G. ;
Hoppe, P. ;
Diederichs, G. ;
Hamm, B. ;
Makowski, M. R. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (02) :92-101
[6]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[7]   A medical device-grade T1 and ECV phantom for global T1 mapping quality assurance-the T1 Mapping and ECV Standardization in cardiovascular magnetic resonance (T1MES) program [J].
Captur, Gabriella ;
Gatehouse, Peter ;
Keenan, Kathryn E. ;
Heslinga, Friso G. ;
Bruehl, Ruediger ;
Prothmann, Marcel ;
Graves, Martin J. ;
Eames, Richard J. ;
Torlasco, Camilla ;
Benedetti, Giulia ;
Donovan, Jacqueline ;
Ittermann, Bernd ;
Boubertakh, Redha ;
Bathgate, Andrew ;
Royet, Celine ;
Pang, Wenjie ;
Nezafat, Reza ;
Salerno, Michael ;
Kellman, Peter ;
Moon, James C. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18 :1-20
[8]   Calibration of myocardial T2 and T1 against iron concentration [J].
Carpenter, John-Paul ;
He, Taigang ;
Kirk, Paul ;
Roughton, Michael ;
Anderson, Lisa J. ;
de Noronha, Sofia V. ;
Baksi, A. John ;
Sheppard, Mary N. ;
Porter, John B. ;
Walker, J. Malcolm ;
Wood, John C. ;
Forni, Gianluca ;
Catani, Gualtiero ;
Matta, Gildo ;
Fucharoen, Suthat ;
Fleming, Adam ;
House, Mike ;
Black, Greg ;
Firmin, David N. ;
St Pierre, Timothy G. ;
Pennell, Dudley J. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[9]   Highly efficient nonrigid motion-corrected 3D whole-heart coronary vessel wall imaging [J].
Cruz, Gastao ;
Atkinson, David ;
Henningsson, Markus ;
Botnar, Rene M. ;
Prieto, Claudia .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) :1894-1908
[10]   Information in magnetic resonance images: Evaluation of signal, noise and contrast [J].
DeWilde, JP ;
Lunt, JA ;
Straughan, K .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (03) :259-265