Low-potential reduction of sulfite at a ruthenium-oxide hexacyanoferrate modified electrode

被引:24
作者
Montes, Rodrigo H. O. [1 ]
Richter, Eduardo M. [1 ]
Munoz, Rodrigo A. A. [1 ]
机构
[1] Univ Fed Uberlandia, Inst Quim, Uberlandia, MG, Brazil
关键词
Sulfite; Ruthenium-oxide hexacyanoferrate; Thin-layer diffusion; Electrocatalysis; FLOW-INJECTION ANALYSIS; THIN-LAYER DIFFUSION; CARBON NANOTUBES; FILMS; BEVERAGES; OXIDATION; KINETICS; FOOD;
D O I
10.1016/j.elecom.2012.05.005
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The low-potential reduction of sulfite at a ruthenium-oxide hexacyanoferrate (RuOHCF)-modified electrode is reported. A decrease (200 mV) in the overpotential of the sulfite reduction reaction and a substantial current increase (compared to the bare glassy-carbon electrode) were verified. Evidence is found for a mass transport regime which includes a thin-layer diffusional process (sulfite species trapped within the RuOHCF film) responsible for the lowered reductive potential (rather than electrocatalytic properties of the film). The low-potential (-0.2 V vs. Ag/AgCl/saturated KCl) amperometric detection of sulfite in 0.25 mol L-1 HCl was free of interferences from substances typically found in food samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 29
页数:4
相关论文
共 23 条
[1]   Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer [J].
Abass, AK ;
Hart, JP ;
Cowell, D .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :148-153
[2]   Determination of sulfur dioxide in wines by gas-diffusion flow injection analysis utilizing modified electrodes with electrostatically assembled films of tetraruthenated porphyrin [J].
Azevedo, CMN ;
Araki, K ;
Toma, HE ;
Angnes, L .
ANALYTICA CHIMICA ACTA, 1999, 387 (02) :175-180
[3]   Development of an electrochemical sulfite biosensor by immobilization of sulfite oxidase on conducting polyaniline film [J].
Bahmani, Baharak ;
Moztarzadeh, Fathollah ;
Rabiee, Mohammad ;
Tahriri, Mohammadreza .
SYNTHETIC METALS, 2010, 160 (23-24) :2653-2657
[4]   Preparation and characterization of ruthenium oxide/hexacyanoferrate and ruthenium hexacyanoferrate mixed films and their electrocatalytic properties [J].
Chen, SM ;
Lu, MF ;
Lin, KC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 579 (01) :163-174
[5]   Application of flow injection analysis for determining sulphites in food and beverages: A review [J].
Claudia, Ruiz-Capillas ;
Francisco, Jimenez-Colmenero .
FOOD CHEMISTRY, 2009, 112 (02) :487-493
[6]   Use of a copper electrode in alkaline medium as an amperometric sensor for sulphite in a flow-through configuration [J].
Corbo, D ;
Bertotti, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (03) :416-420
[7]   A novel electroreduction strategy for the determination of sulfite [J].
Isaac, A ;
Wain, AJ ;
Compton, RG ;
Livingstone, C ;
Davis, J .
ANALYST, 2005, 130 (10) :1343-1344
[8]   Electroanalytical methods for the determination of sulfite in food and beverages [J].
Isaac, Anita ;
Livingstone, Callum ;
Wain, Andrew J. ;
Compton, Richard G. ;
Davis, James .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (06) :589-598
[9]  
Keeley GP, 2009, INT J ELECTROCHEM SC, V4, P794
[10]  
Machado RMD, 2008, BRAZ J FOOD TECHNOL, V11, P226