Estimation of Mean Blood Pressure from Oscillometric and Manual Methods

被引:4
|
作者
Zheng, D. [1 ]
Murray, A. [1 ]
机构
[1] Univ Newcastle, Freeman Hosp, Dept Reg Med Phys, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
来源
COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2 | 2008年
关键词
D O I
10.1109/CIC.2008.4749198
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim of this study was to estimate mean blood pressure from oscillometric and manual methods. Ten healthy subjects were studied with three repeat blood pressure measurements. Manual systolic and diastolic blood pressures (SBP and DBP) were obtained by two trained observers. During the measurement the oscillometric cuff pressure waveform was recorded digitally. The cuff pressure corresponding to the largest oscillometric pulse pressure was taken as the mean arterial pressure (AMP). AMP was also estimated from manual DBP plus one third the pressure change from DBP to SBP. Blood pressure measurement variability and the difference between automated and manual MAP were quantified. The overall coefficients of variabilily for manual SBP and DBP were 2.2% and 4.5%. Corresponding values for manual and automated MAP were 3.1% and 3.7%. The automated MAP, as a percentage of the difference between manual DBP and SBP was 28 +/- 14% (mean SD), which was lower than the classically assumed mean value of 33%. In conclusion, the relationship between MAP and SBP and DBP is complex with a large between-subject SD variability of 14%.
引用
收藏
页码:941 / 944
页数:4
相关论文
共 50 条
  • [1] Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques
    Zheng, Dingchang
    Amoore, John N.
    Mieke, Stephan
    Murray, Alan
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (01) : 33 - 39
  • [2] Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques
    Dingchang Zheng
    John N. Amoore
    Stephan Mieke
    Alan Murray
    Medical & Biological Engineering & Computing, 2011, 49 : 33 - 39
  • [3] Effect of Talking on Mean Arterial Blood Pressure: Agreement between Manual Auscultatory and Automatic Oscillometric Techniques
    Zheng, Dingchang
    Giovannini, Roberto
    Murray, Alan
    2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 841 - 844
  • [4] Inaccuracy in Determining Mean Arterial Pressure With Oscillometric Blood Pressure Techniques
    Vos, Jorn
    Vincent, Hieronymus H.
    Verhaar, Marianne C.
    Bos, Willem J. W.
    AMERICAN JOURNAL OF HYPERTENSION, 2013, 26 (05) : 624 - 629
  • [5] Model-Based Mean Arterial Pressure Estimation Using Simultaneous Electrocardiogram and Oscillometric Blood Pressure Measurements
    Forouzanfar, Mohamad
    Ahmad, Saif
    Batkin, Izmail
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (09) : 2443 - 2452
  • [6] Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs
    Haberman, Christopher E.
    Kang, Chang W.
    Morgan, Jefferson D.
    Brown, Scott A.
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2006, 70 (03): : 211 - 217
  • [7] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Cheng, Hao-Min
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Chen, Lung-Ching
    Sung, Shih-Hsien
    Ding, Philip Yu-An
    Yu, Wen-Chung
    Chen, Jaw-Wen
    Chen, Chen-Huan
    HYPERTENSION RESEARCH, 2010, 33 (06) : 592 - 599
  • [8] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Hao-Min Cheng
    Kang-Ling Wang
    Ying-Hwa Chen
    Shing-Jong Lin
    Lung-Ching Chen
    Shih-Hsien Sung
    Philip Yu-An Ding
    Wen-Chung Yu
    Jaw-Wen Chen
    Chen-Huan Chen
    Hypertension Research, 2010, 33 : 592 - 599
  • [9] Oscillometric blood pressure estimation: Past, present, and future
    School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa
    K1N 6N5, Canada
    不详
    MA
    02138, United States
    IEEE Rev. Biomed. Eng., (44-63):
  • [10] Model-Based Oscillometric Blood Pressure Estimation
    Forouzanfar, Mohamad
    Dajani, Hilmi R.
    Groza, Voicu Z.
    Bolic, Miodrag
    2014 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2014, : 443 - 448