The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

被引:15
|
作者
Keating, Kristina [1 ]
Walsh, David O. [2 ]
Grunewald, Elliot [2 ]
机构
[1] Rutgers State Univ, Dept Earth & Environm Sci, 101 Warren St,Smith Hall Room 135, Newark, NJ 07102 USA
[2] Vista Clara Inc, 12201 Cyrus Way 104, Mukilteo, WA 98275 USA
关键词
PARTICLE-SIZE DISTRIBUTION; SOIL; DISTRIBUTIONS; WATER; INHOMOGENEITY; PERMEABILITY; MODEL;
D O I
10.1016/j.jappgeo.2020.104096
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The presence of materials with high magnetic susceptibility are known to have an impact on H-1 nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 x 10(-6) to 7020 x 10(-6) SI. The results show that for materials with low magnetic susceptibility (<378 x 10(-6) SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 x 10(-6) SI) the gravimetric porosity is poorly predicted from the 2MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2MHz NMR instrument, which has a homogeneous applied magnetic field. We conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Molecular dynamics and composition of crude oil by low-field nuclear magnetic resonance
    Jia, Zijian
    Xiao, Lizhi
    Wang, Zhizhan
    Liao, Guangzhi
    Zhang, Yan
    Liang, Can
    MAGNETIC RESONANCE IN CHEMISTRY, 2016, 54 (08) : 650 - 655
  • [42] Experimental study on drying characteristics of wheat by low-field nuclear magnetic resonance
    Jia, Chao
    Wang, Li
    Li, Ran
    Liu, Chuanping
    DRYING TECHNOLOGY, 2017, 35 (10) : 1258 - 1265
  • [43] Experimental study on drying characteristics of rice by low-field nuclear magnetic resonance
    Wang, Hongchao
    Che, Gang
    Wan, Lin
    Liu, Menggang
    Sun, Wensheng
    JOURNAL OF FOOD PROCESS ENGINEERING, 2021, 44 (06)
  • [44] LOW-FIELD CINE MAGNETIC-RESONANCE-IMAGING
    JONES, RA
    METCALFE, MJ
    REDPATH, TW
    SMITH, FW
    WALTON, S
    BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (745): : 65 - 68
  • [45] Low-field magnetic resonance imaging for implant dentistry
    Gray, CF
    Redpath, TW
    Smith, FW
    DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (04) : 225 - 229
  • [46] Chemical analysis using low-field magnetic resonance
    Donaldson, Marcus
    Freed, Denise
    Mandal, Soumyajit
    Song, Yi-Qiao
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 83 : 84 - 93
  • [47] Low-field He-3 nuclear magnetic resonance in human lungs
    Darrasse, L
    Guillot, G
    Nacher, PJ
    Tastevin, G
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II FASCICULE B-MECANIQUE PHYSIQUE CHIMIE ASTRONOMIE, 1997, 324 (11): : 691 - 700
  • [48] Evaluation of ageing in asphalt cores using low-field nuclear magnetic resonance
    Menapace, Ilaria
    Masad, Eyad
    Papavassiliou, Georgios
    Kassem, Emad
    INTERNATIONAL JOURNAL OF PAVEMENT ENGINEERING, 2016, 17 (10) : 847 - 860
  • [49] Pulsed low-field electrically detected magnetic resonance
    Dreher, L.
    Hoehne, F.
    Morishita, H.
    Huebl, H.
    Stutzmann, M.
    Itoh, K. M.
    Brandt, M. S.
    PHYSICAL REVIEW B, 2015, 91 (07):
  • [50] Low-field magnetic resonance imaging for rheumatoid athritis
    Ostendorf, B.
    Edelmann, E.
    Kellner, H.
    Scherer, A.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2010, 69 (01): : 79 - +