Detection of focal renal perfusion defects in rabbits after sulphur hexafluoride-filled microbubble injection at low transmission power ultrasound insonation

被引:10
作者
Quaia, E
Siracusano, S
Palumbo, A
Ciciliato, S
Rossi, S
Bruni, S
Bussani, R
Cova, M
机构
[1] Cattinara Hosp, Dept Radiol, I-34149 Trieste, Italy
[2] Cattinara Hosp, Dept Urol, Trieste, Italy
[3] Cattinara Hosp, Dept Pathol, Trieste, Italy
关键词
ultrasound; microbubble; renal infarction; renal perfusion defect;
D O I
10.1007/s00330-005-2866-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess the feasibility of contrast-enhanced ultrasound (US) at low transmission power insonation for diagnosis of focal renal perfusion defects (RPDs) in rabbits. In seven adult New Zealand White rabbits focal RPDs were induced by polyvinyl alcohol embolizing particles (150-250 mu m in diameter) injected into the abdominal aorta. Three other rabbits that were not subjected to embolization were considered as controls. Both kidneys were insonated at baseline and after injection of sulphur hexafluoride-filled microbubbles at low transmission power (mechanical index 0.09-0.12). One sonologist assessed on-site RPD dimensions and conspicuity (visual score 0-4). Digital cine-clips were also reviewed off-site by two other independent readers, blinded, who assigned a confidence level (grades 1-5) for the RPD diagnosis. At on-site analysis RPDs appeared as focal areas of absent or diminished enhancement with a median visual conspicuity score=4. At off-site analysis RPDs > 6 mm in diameter were identified at contrast-enhanced US, and the confidence in RPD diagnosis improved significantly (P < 0.05) after microbubble injection (area under receiver operating characteristic curve 0.615 vs 0.972 by reader 1; 0.720 vs 0.953 by reader 2). Contrast-enhanced US at low transmission power insonation effectively identified RPDs with diameters > 6 mm in rabbits.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 27 条
[1]  
BECK JR, 1986, ARCH PATHOL LAB MED, V110, P13
[2]   Renal blood flow in pigs: Changes depicted with contrast-enhanced harmonic US imaging during acute urinary obstruction [J].
Claudon, M ;
Barnewolt, CE ;
Taylor, GA ;
Dunning, PS ;
Gobet, R ;
Badawy, AB .
RADIOLOGY, 1999, 212 (03) :725-731
[3]   POTENTIAL ROLE OF PFOB ENHANCED SONOGRAPHY OF THE KIDNEY .2. DETECTION OF PARTIAL INFARCTION [J].
COLEY, BD ;
MATTREY, RF ;
ROBERTS, A ;
KEANE, S .
KIDNEY INTERNATIONAL, 1991, 39 (04) :740-745
[4]  
Correas JM, 2003, J RADIOL, V84, P2041
[5]   Contrast-enhanced ultrasonography of native and transplanted kidney diseases [J].
Correas, JM ;
Hélénon, O ;
Moreau, JF .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S394-S400
[6]   Comparison of standard and second harmonic B-mode sonography in the detection of segmental renal infarction with sonographic contrast in a rabbit model [J].
Girard, MS ;
Mattrey, RF ;
Baker, KG ;
Peterson, T ;
Deiranieh, LH ;
Steinbach, GC .
JOURNAL OF ULTRASOUND IN MEDICINE, 2000, 19 (03) :185-192
[7]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[8]   Safety of ultrasound contrast agents [J].
Jakobsen, JÅ ;
Oyen, R ;
Thomsen, HS ;
Morcos, SK .
EUROPEAN RADIOLOGY, 2005, 15 (05) :941-945
[9]   CT evaluation of renovascular disease [J].
Kawashima, A ;
Sandler, CM ;
Ernst, RD ;
Tamm, EP ;
Goldman, SM ;
Fishman, EK .
RADIOGRAPHICS, 2000, 20 (05) :1321-1340
[10]  
Kim B, 2001, J ULTRAS MED, V20, P5