Large-volume ionization chamber with variable apertures for air-kerma measurements of low-energy radiation sources

被引:19
作者
Culberson, WS [1 ]
DeWerd, LA [1 ]
Anderson, DR [1 ]
Micka, JA [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
D O I
10.1063/1.2148997
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This report describes the design and initial measurement results of a large-volume ionization chamber designed to realize the air kerma from therapeutic radiation sources emitting photons with energies up to about 70 keV. The measured ionization current is used to provide absolute source calibrations by the most widely used brachytherapy source strength metric called air-kerma strength. The variable-aperture free-air chamber (VAFAC), named because of its variable aperture stand, will provide insight into the angular dependence of air-kerma strength measurements. Another unique feature of this ionization chamber is its seed holder design that reduces unwanted scatter, ensures vertical positioning, and rotates the seed with a positional accuracy of 0.3 degrees. Benchmark experiments show that the VAFAC agrees well with existing National Institute of Standards and Technology standards and is capable of measuring clinical-strength seeds with repeatabilities of less than 2% at the 1 sigma level (k=1). (c) 2006 American Institute of Physics.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 12 条
  • [1] REEVALUATION OF THE W-VALUE FOR ELECTRONS IN DRY AIR
    BOUTILLON, M
    PERROCHEROUX, AM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (02) : 213 - 219
  • [2] Procedures for establishing and maintaining consistent air-kerma strength standards for low-energy, photon-emitting brachytherapy sources: Recommendations of the Calibration Laboratory Accreditation Subcommittee of the American Association of Physicists in Medicine
    DeWerd, LA
    Huq, MS
    Das, IJ
    Ibbott, GS
    Hanson, WF
    Slowey, TW
    Williamson, JF
    Coursey, BM
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 675 - 681
  • [3] GOORLEY T, 2003, LAUR031987
  • [4] Kramer H, COMMUNICATION, V81, P5
  • [5] Assessment of a prostate treatment plan using directional brachytherapy sources
    Lin, L
    Chaswal, V
    Henderson, DL
    Thomadsen, BR
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2098 - 2098
  • [6] DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43
    NATH, R
    ANDERSON, LL
    LUXTON, G
    WEAVER, KA
    WILLIAMSON, JF
    MEIGOONI, AS
    [J]. MEDICAL PHYSICS, 1995, 22 (02) : 209 - 234
  • [7] Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    Rivard, MJ
    Coursey, BM
    DeWerd, LA
    Hanson, WF
    Huq, MS
    Ibbott, GS
    Mitch, MG
    Nath, R
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 633 - 674
  • [8] New national air-kerma-strength standards for 125I and 103Pd brachytherapy seeds
    Seltzer, SM
    Lamperti, PJ
    Loevinger, R
    Mitch, MG
    Weaver, JT
    Coursey, BM
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2003, 108 (05) : 337 - 358
  • [9] Taylor B.N., 1994, 1297 NIST, P1
  • [10] Monte Carlo modeling of the transverse-axis dose distribution of the Model 200 103Pd interstitial brachytherapy source
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2000, 27 (04) : 643 - 654