Interlaboratory validation of an environmental monitoring method for trace analysis of endocrine disrupting compounds

被引:3
作者
Mansilha, Catarina [1 ]
Rocha, Sonia [2 ]
Gameiro, Paula [2 ]
Pinho, Carina [3 ]
Ferreira, Isabel M. P. L. V. O. [3 ]
Silva, Poliana [4 ]
Domingues, Valentina [5 ]
机构
[1] Inst Nacl Saude Dr Ricardo Jorge, P-4000055 Oporto, Portugal
[2] Univ Porto, Fac Ciencias, P-4169007 Oporto, Portugal
[3] Univ Porto, Fac Farm, P-4050047 Oporto, Portugal
[4] CECA, Vairao, Vila Do Conde, Portugal
[5] Inst Politecn Porto, Inst Super Engn Porto, P-4200072 Oporto, Portugal
关键词
CHROMATOGRAPHY-MASS SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; GAS-CHROMATOGRAPHY; BISPHENOL-A; ESTROGENS ESTRONE; RESIDUE ANALYSIS; WATER; 17-ALPHA-ETHINYLESTRADIOL; DERIVATIZATION; N-(TERT-BUTYLDIMETHYLSILYL)-N-METHYLTRIFLUOROACETAMIDE;
D O I
10.1039/c2ay25450f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17 beta-estradiol and 17 alpha-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.
引用
收藏
页码:3724 / 3732
页数:9
相关论文
共 46 条
[1]  
Agencia Nacional de Vigilancia Sanitaria (ANVISA), 2003, GUIA VAL MET AN BIOA
[2]   Residue analysis of 500 high priority pesticides: Better by GC-MS or LC-MS/MS? [J].
Alder, Lutz ;
Greulich, Kerstin ;
Kempe, Guenther ;
Vieth, Barbel .
MASS SPECTROMETRY REVIEWS, 2006, 25 (06) :838-865
[3]  
[Anonymous], 2001, GUID IND BIOAN METH
[4]  
[Anonymous], 2004, SANCO82500 EUR COMM
[5]  
[Anonymous], EM CONT
[6]  
[Anonymous], 1998, FITN PURP AN METH LA
[7]  
[Anonymous], 2010, SANCO106842009 EUR C
[8]  
[Anonymous], 2003, DOQCGCRE008 INM
[9]  
[Anonymous], INT C HARMONISATION
[10]  
[Anonymous], 1999, 170251999 ISOIEC