Corrosion and Hydrogen Permeation in H2S Environments with O2 Contamination, Part 2: Impact of H2S Partial Pressure

被引:3
|
作者
Ayagou, Martien Duvall Deffo [1 ]
Joshi, Gaurav R. [2 ]
Thi Tuyet Mai Tran [3 ]
Sutter, Eliane [3 ]
Tribollet, Bernard [3 ]
Mendibide, Christophe [1 ]
Duret-Thual, Claude [1 ]
Ferrando, Nicolas [4 ]
Kittel, Jean [2 ]
机构
[1] Inst Corros Site St Etienne, ZA Parc Sect Gampille, F-42490 Fraisse, France
[2] IFP Energies Nouvelles, Rond Point Echangeur Solaize BP3, F-69360 Solaize, France
[3] Sorbonne Univ, CNRS, LISE, F-75005 Paris, France
[4] IFP Energies Nouvelles, 1&4 Ave Bois Preau, F-92852 Rueil Malmaison, France
关键词
hydrogen-induced cracking; hydrogen permeation; hydrogen sulfide; sulfide stress cracking; REDUCTION;
D O I
10.5006/3092
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Materials selection in the oil and gas industry relies on engineering standards, such as NACE TM0177 and NACE TM0284, which stipulate that oxygen contamination should be avoided during materials testing in H2S-containing media. In this second paper, as part of a series of articles that evaluates how traces of oxygen modify the corrosion of pure iron and hydrogen permeation across iron membranes in H2S-containing solutions, the impact of changing the H2S partial pressure from 100 kPa to 0.1 kPa was investigated. It was found that bulk solution chemistry for all H2S partial pressures changes with time, due to the formation of H2S-O-2 reaction products (sulfates, sulfites, and thiosulfates), which results in bulk solution acidification. Electrochemical and weight-loss measurements confirm that Fe corrosion rates in baseline well-deaerated H2S-containing solutions decrease with decreasing H2S partial pressure, although these are observed to be much higher under continuous oxygen contamination. With decreasing H2S partial pressure, hydrogen uptake in Fe also decreases, due to lower and lower concentrations of dissolved H2S and the associated increase in pH. However, even at 1 kPa and 0.1 kPa H2S, permeation effciencies remain close to 100% when no O-2 contamination is present. The hydrogen uptake is always relatively lower in Fe exposed to oxygen-polluted H2S solutions. Permeation efficiencies decrease continuously. From electrochemical data and surface characterization, these observations at lower H2S partial pressures are attributed to the disruptive effect of oxygen on the nature of sulfide corrosion products, and hydrogen entry promotion, along with the contribution of an additional cathodic reaction that does not result in hydrogen entry into the metal.
引用
收藏
页码:389 / 397
页数:9
相关论文
共 50 条
  • [1] Corrosion and Hydrogen Permeation in H2S Environments with O2 Contamination, 1: Tests on Pure Iron at High H2S Concentration
    Ayagou, Martien Duvall Deffo
    Mendibide, C.
    Duret-Thual, Claude
    Kittel, Jean
    Belkhadiri, Khawla
    Thi Tuyet Mai Tran
    Sutter, Eliane
    Tribollet, Bernard
    Ferrando, Nicolas
    CORROSION, 2018, 74 (11) : 1192 - 1202
  • [2] Corrosion and Hydrogen Permeation in H2S Environments with O2 Contamination, Part 3: The Impact of Acetate-Buffered Test Solution Chemistry
    Joshi, Gaurav R.
    Ayagou, Martien Duvall Deffo
    Mendibide, C.
    Tran, Thi Tuyet Mai
    Tribollet, Bernard
    Kittel, Jean
    CORROSION, 2021, 77 (09) : 961 - 975
  • [3] H2S and O2 sensing
    Olson, Kenneth R.
    Perry, Steve F.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (37) : 15997 - 15997
  • [4] Effect of H2S Partial Pressure on CO2/H2S Corrosion of Oil Tube Steels
    Wang, Ying
    Li, Ping
    ADVANCED MATERIALS, PTS 1-4, 2011, 239-242 : 3131 - 3134
  • [5] Ru(EDTA) mediated partial reduction of O2 by H2S
    Chatterjee, Debabrata
    Jaiswal, Namita
    Sarkar, Papiya
    DALTON TRANSACTIONS, 2015, 44 (16) : 7613 - 7617
  • [6] EFFECTS OF H2S AND H2O ON HYDROGEN PERMEATION IN STAINLESS-STEELS
    PERNG, TP
    ALTSTETTER, CJ
    JOURNAL OF METALS, 1984, 36 (07): : 18 - 18
  • [7] The effect of the partial pressure of H2S on the permeation of hydrogen in low carbon pipeline steel
    Zhou, Chengshuang
    Zheng, Shuqi
    Chen, Changfeng
    Lu, Guiwu
    CORROSION SCIENCE, 2013, 67 : 184 - 192
  • [8] Plasma dissociation of H2S with O2 addition
    Nunnally, T.
    Gutsol, K.
    Rabinovich, A.
    Fridman, A.
    Gutsol, A.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (24) : 12480 - 12489
  • [9] Aqueous H2S corrosion
    不详
    MATERIALS PERFORMANCE, 1999, 38 (08) : 73 - 74
  • [10] Dry H2S corrosion
    不详
    MATERIALS PERFORMANCE, 2005, 44 (06) : 11 - 11