Rotational limb alignment changes following total knee arthroplasty

被引:18
作者
Hauschild, Oliver [1 ]
Muenzberg, Matthias [2 ]
Knothe, Dagmar [3 ]
Konstantinidis, Lukas [1 ]
Helwig, Peter [1 ]
Sudkamp, Norbert P. [1 ]
Thielemann, Friedrich W. [4 ]
机构
[1] Univ Freiburg, Med Ctr, Dept Orthoped & Trauma Surg, D-79106 Freiburg, Germany
[2] Heidelberg Univ, BG Trauma Ctr Ludwigshafen, Ludwigshafen, Germany
[3] Tuttlingen Hosp, Dept Diagnost Radiol, Tuttlingen, Germany
[4] Schwarzwald Baar Hosp, Dept Trauma Hand & Reconstruct Surg, Villingen Schwenningen, Germany
关键词
Rotational limb alignment; TKA; Component placement; Reproducibility; Computed tomography; OSTEOARTHRITIC KNEES; FEMORAL COMPONENT; TIBIAL COMPONENT; DISTAL FEMUR; MRI ANALYSIS; CT-SCAN; TOMOGRAPHY; TORSION; MALROTATION; ACCURACY;
D O I
10.1007/s00167-012-2322-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of the present study was to assess the changes in rotational alignment introduced by total knee arthroplasty (TKA) and the reproducibility of pre- and postoperative CT measurements of rotational limb alignment. For this purpose we analyzed data from 196 consecutive cruciate-retaining, fixed bearing Columbus TKA procedures. Both pre- and postoperative scans torsion difference CT scans were available for measurements in 89 cases. Using these CT scans the neck-malleolar angle (NMA), the femoral posterior condylar angle (fPCA), the tibial posterior condylar axis (tPCA) and the tibial torsion angle (TTA) were independently assessed by three raters. CT scans were re-evaluated 8 weeks later by the most experienced rater for assessment of intraobserver agreement. Measurements of all angles were prone to high standard deviations reflecting interindividual variability. Mean fPCA changed from 1.3A degrees to 2.7A degrees internal rotation preoperatively to 0.1A degrees-1.9A degrees internal rotation postoperatively. Based on a relative external rotation of the tibial base plate as compared to the preoperative situation, we found a relative internal rotation of the postoperative NMA and tibial torsion of 3A degrees-5.4A degrees and 6A degrees-7.5A degrees, respectively. Intra- and interobserver agreement was strong for all angles assessed (ICCs 0.7-1.0) except for fPCA (ICC 0.2-0.6). However, mean absolute measurement differences for fPCA were clinically acceptable (1.2A degrees-2.6A degrees). Reproducibility of CT rotational limb alignment measurements was found to be clinically acceptable. Rotational alignment of the femoral and even more so of the tibial component will ultimately affect the rotational alignment of the entire limb-at least when fixed bearings are used. Diagnostic study, Level III.
引用
收藏
页码:2346 / 2354
页数:9
相关论文
共 33 条
[1]  
Akagi M, 1999, CLIN ORTHOP RELAT R, P155
[2]   Variability of extraarticular tibial rotation references for total knee arthroplasty [J].
Akagi, M ;
Mori, S ;
Nishimura, S ;
Nishimura, A ;
Asano, T ;
Hamanishi, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :172-176
[3]  
BERGER RA, 1993, CLIN ORTHOP RELAT R, P40
[4]   Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[5]   Rotational instability and malrotation after total knee arthroplasty [J].
Berger, RA ;
Rubash, HE .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :639-+
[6]   Is the Anterior Tibial Tuberosity a Reliable Rotational Landmark for the Tibial Component in Total Knee Arthroplasy? [J].
Bonnin, Michel P. ;
Saffarini, Mohammed ;
Mercier, Pierre-Etienne ;
Laurent, Jean-Raphael ;
Carrillon, Yannick .
JOURNAL OF ARTHROPLASTY, 2011, 26 (02) :260-267
[7]   Distal femoral torsion: Comparison of CT scan and intra operative navigation measurements during total knee arthroplasty A report of 70 cases [J].
Galaud, B. ;
Beauflis, P. ;
Michaut, M. ;
Abadie, P. ;
Fallet, L. ;
Boisrenoult, P. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (06) :573-579
[8]   CT Scans Increase Rotational Accuracy in Total Knee Arthroplasty [J].
Grafinger, R. W. ;
Datz, L. ;
Hitzl, W. ;
Dorn, U. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2008, 146 (06) :782-787
[9]   The posterior condylar angle in osteoarthritic knees [J].
Griffin, FM ;
Insall, JN ;
Scuderi, GR .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :812-815
[10]   Anatomy of the epicondyles of the distal femur - MRI analysis of normal knees [J].
Griffin, FM ;
Math, K ;
Scuderi, GR ;
Insall, JN ;
Poilvache, PL .
JOURNAL OF ARTHROPLASTY, 2000, 15 (03) :354-359