Waste incineration of Polytetrafluoroethylene (PTFE) to evaluate potential formation of per- and Poly-Fluorinated Alkyl Substances (PFAS) in flue gas

被引:69
作者
Aleksandrov, Krasimir [1 ]
Gehrmann, Hans-Joachim [1 ]
Hauser, Manuela [1 ]
Maetzing, Hartmut [1 ]
Pigeon, Daniel [2 ]
Stapf, Dieter [1 ]
Wexler, Manuela [1 ]
机构
[1] Karlsruhe Inst Technol, D-76021 Karlsruhe, Germany
[2] WL Gore & Assoc Inc, Elkton, MD 21901 USA
关键词
PFAS; Polytetrafluoroethylene; Waste incineration; Flue gas sampling; Paired t-test; PFOA/PFOS;
D O I
10.1016/j.chemosphere.2019.03.191
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent years, concerns over some per- and polyfluorinated alkyl substances (PFAS) have grown steadily. PFAS are a large group of chemical substances with widely differing properties. While one class of PFAS, fluoropolymers, have been demonstrated to meet the OECD criteria for polymers of low concern during the in use phase of their lifecycle, questions remain regarding waste handling at the end of useful life for products containing fluoropolymers. To show that polytetrafluoroethylene (PTFE) can be almost fully transformed into fluorine (F) (as hydrofluoric acid (HF)) and to study the possible generation of low molecular weight per- and polyfluorinated alkyl substances (PFAS), PTFE combustion under typical waste incineration conditions at the BRENDA (German acronym for "Brennkammer mit Dampfkessel") pilot plant at Karlsruhe Institute of Technology (KIT) was investigated. Results indicate that, within procedural quantitation limits, no statistically significant evidence was found that the PFAS studied were created during the incineration of PTFE. Therefore, municipal incineration of PTFE using best available technologies (BAT) is not a significant source of the studied PFAS and should be considered an acceptable form of waste treatment. (C) 2019 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:898 / 906
页数:9
相关论文
共 21 条
[1]  
[Anonymous], 2008, DIN32645
[2]  
[Anonymous], 2010, OJ
[3]  
[Anonymous], 2006, INTEGRATED POLLUTION
[4]  
ARITO H, 1977, Annals of Occupational Hygiene, V20, P247, DOI 10.1093/annhyg/20.3.247
[5]   The use of 19F NMR and mass spectrometry for the elucidation of novel fluorinated acids and atmospheric fluoroacid precursors evolved in the thermolysis of fluoropolymers [J].
Ellis, DA ;
Martin, JW ;
Muir, DCG ;
Mabury, SA .
ANALYST, 2003, 128 (06) :756-764
[6]  
Fazullin D.D., 2015, MOD APPL SCI, V9, P242, DOI [10.5539/mas.v9n1p242, DOI 10.5539/MAS.V9N1P242]
[7]  
Gehrmann H. J., 2005, MATHEMATISCHE MODELL
[8]  
Gehrmann HJ, 2017, J ENG-NY, V2017, DOI 10.1155/2017/3567865
[9]   A critical review of the application of polymer of low concern and regulatory criteria to fluoropolymers [J].
Henry, Barbara J. ;
Carlin, Joseph P. ;
Hammerschmidt, Jon A. ;
Buck, Robert C. ;
Buxton, L. William ;
Fiedler, Heidelore ;
Seed, Jennifer ;
Hernandez, Oscar .
INTEGRATED ENVIRONMENTAL ASSESSMENT AND MANAGEMENT, 2018, 14 (03) :316-334
[10]  
Japan MOE, 2001, MAN DET DIOX AMB AIR