Comparison of navigation accuracy in THA between the mini-anterior and -posterior approaches

被引:28
作者
Hananouchi, Takehito [1 ]
Takao, Masaki [1 ]
Nishii, Takashi [1 ]
Miki, Hidenobu [2 ]
Iwana, Daiki [3 ]
Yoshikawa, Hideki [1 ]
Sugano, Nobuhiko [4 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthopaed Surg, Osaka, Japan
[2] Osaka Med Ctr, Dept Orthopaed Surg, Osaka, Japan
[3] Kyowakai Hosp, Ctr Arthroplasty, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Orthopaed Med Engn, Osaka, Japan
关键词
CT-based hip navigation; total hip arthroplasty; mini-incision surgery; surface registration; TOTAL HIP-ARTHROPLASTY; COMPONENT; INCISION;
D O I
10.1002/rcs.226
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The accuracy of a CT-based hip navigation might depend on surgical approaches, resulting in varying accuracy of implant alignment. Methods We performed primary cementless total hip arthroplasty (THA) with mini-incision surgery (MIS) to 40 well-matched patients (anterior or posterior approaches, 20 hips each), using navigation with surface registration. We investigated cup alignment using postoperative computed tomography (CT) and compared the navigation accuracy between the two approaches, i.e. the difference between intra-operative and postoperative alignments of the cup. Results There was no significant difference between the two approaches. The mean navigation accuracies in abduction and anteversion were 2.0 degrees (SD 1.4 degrees) and 2.7 degrees (SD 1.9 degrees), respectively, in the anterior approach, and 2.4 degrees (SD 2.0 degrees) and 2.0 degrees (SD 1.4 degrees), respectively, in the posterior approach. All cup alignments were within 100 of the target orientation. Conclusions This CT-based navigation for MIS-THA provides navigation accuracy without significant differences between the two approaches and with favourable alignment of the cup. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 16 条
  • [11] THE DEFINITION AND MEASUREMENT OF ACETABULAR ORIENTATION
    MURRAY, DW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02): : 228 - 232
  • [12] Influence of component positions on dislocation - Computed tomographic evaluations in a consecutive series of total hip arthroplasty
    Nishii, T
    Sugano, N
    Miki, H
    Koyama, T
    Takao, M
    Yoshikawa, H
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (02) : 162 - 166
  • [13] Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation
    Sugano, N.
    Nishii, T.
    Miki, H.
    Yoshikawa, H.
    Sato, Y.
    Tamura, S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04): : 455 - 460
  • [14] Sugano N, 2001, Comput Aided Surg, V6, P195, DOI 10.1002/igs.10011
  • [15] Watanabe Y., 2003, Medical Imaging Technology, V21, P358
  • [16] Comparison of primary total hip replacements performed with a standard incision or a mini-incision
    Woolson, ST
    Mow, CS
    Syquia, JF
    Lannin, JV
    Schurman, DJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (07) : 1353 - 1358