Comparison of navigation accuracy in THA between the mini-anterior and -posterior approaches

被引:28
作者
Hananouchi, Takehito [1 ]
Takao, Masaki [1 ]
Nishii, Takashi [1 ]
Miki, Hidenobu [2 ]
Iwana, Daiki [3 ]
Yoshikawa, Hideki [1 ]
Sugano, Nobuhiko [4 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthopaed Surg, Osaka, Japan
[2] Osaka Med Ctr, Dept Orthopaed Surg, Osaka, Japan
[3] Kyowakai Hosp, Ctr Arthroplasty, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Orthopaed Med Engn, Osaka, Japan
关键词
CT-based hip navigation; total hip arthroplasty; mini-incision surgery; surface registration; TOTAL HIP-ARTHROPLASTY; COMPONENT; INCISION;
D O I
10.1002/rcs.226
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The accuracy of a CT-based hip navigation might depend on surgical approaches, resulting in varying accuracy of implant alignment. Methods We performed primary cementless total hip arthroplasty (THA) with mini-incision surgery (MIS) to 40 well-matched patients (anterior or posterior approaches, 20 hips each), using navigation with surface registration. We investigated cup alignment using postoperative computed tomography (CT) and compared the navigation accuracy between the two approaches, i.e. the difference between intra-operative and postoperative alignments of the cup. Results There was no significant difference between the two approaches. The mean navigation accuracies in abduction and anteversion were 2.0 degrees (SD 1.4 degrees) and 2.7 degrees (SD 1.9 degrees), respectively, in the anterior approach, and 2.4 degrees (SD 2.0 degrees) and 2.0 degrees (SD 1.4 degrees), respectively, in the posterior approach. All cup alignments were within 100 of the target orientation. Conclusions This CT-based navigation for MIS-THA provides navigation accuracy without significant differences between the two approaches and with favourable alignment of the cup. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 16 条
  • [1] Poor accuracy of freehand cup positioning during total hip arthroplasty
    Bosker, B. H.
    Verheyen, C. C. P. M.
    Horstmann, W. G.
    Tulp, N. J. A.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) : 375 - 379
  • [2] Mini-incision technique for total hip arthroplasty with navigation
    DiGioia, AM
    Plakseychuk, AY
    Levison, TJ
    Jaramaz, B
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (02) : 123 - 128
  • [3] Surface-based registration of CT images to physical space for image-guided surgery of the spine: A sensitivity study
    Herring, JL
    Dawant, BM
    Maurer, CR
    Muratore, DM
    Galloway, RL
    Fitzpatrick, JM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 743 - 752
  • [4] Jaramaz B, 1998, CLIN ORTHOP RELAT R, V355, P8
  • [5] Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation?
    Kalteis, T
    Handel, A
    Bäthis, H
    Perlick, L
    Tingart, M
    Grifka, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02): : 163 - 167
  • [6] Total hip arthroplasty through a minimally invasive anterior surgical approach
    Kennon, RE
    Keggi, JM
    Wetmore, RS
    Zatorski, LE
    Huo, MH
    Keggi, KJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 39 - 48
  • [7] DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES
    LEWINNEK, GE
    LEWIS, JL
    TARR, R
    COMPERE, CL
    ZIMMERMAN, JR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) : 217 - 220
  • [8] The science of minimally invasive total hip arthroplasty
    Malik, Aamer
    Dorr, Lawrence D.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) : 74 - 84
  • [9] The effect of fixation and location on the stability of the markers in navigated total hip arthroplasty - A Cadaver study
    Mayr, E
    de la Barrera, JLM
    Eller, G
    Bach, C
    Nogler, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02): : 168 - 172
  • [10] THA performed using conventional and navigated tissue-preserving techniques
    Murphy, Stephen B.
    Ecker, Tinto M.
    Tannast, Moritz
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 160 - 167