Core temperature responses to compensable versus uncompensable heat stress in young adults (PSU HEAT Project)

被引:29
作者
Cottle, Rachel M. [1 ,2 ]
Lichter, Zachary S. [1 ]
Vecellio, Daniel J. [2 ]
Wolf, S. Tony [1 ]
Kenney, W. Larry [1 ,2 ,3 ]
机构
[1] Penn State Univ, Dept Kinesiol, University Pk, PA 16802 USA
[2] Penn State Univ, Coll Hlth & Human Dev, Ctr Hlth Aging, University Pk, PA 16802 USA
[3] Penn State Univ, Grad Program Physiol, University Pk, PA USA
基金
美国国家卫生研究院;
关键词
activities of daily living; climate change; core temperature; heat wave; temperature regulation; CRITICAL EVAPORATIVE COEFFICIENTS; CRITICAL ENVIRONMENTAL LIMITS; PSYCHROMETRIC LIMITS; EXERCISE; WORK; ACCLIMATION; SURFACE; SYSTEM; MEN;
D O I
10.1152/japplphysiol.00388.2022
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
With global warming, much attention has been paid to the upper limits of human adaptability. However, the time to reach a gen-erally accepted core temperature criterion (40.2 degrees C) associated with heat-related illness above (uncompensable heat stress) and just below (compensable heat stress) the upper limits for heat balance remains unclear. Forty-eight (22 men/26 women; 23 +/- 4 yr) subjects were exposed to progressive heat stress in an environmental chamber during minimal activity (MinAct, 159 +/- 34 W) and light ambulation (LightAmb, 260 +/- 55 W) in warm-humid (WH; -35 degrees C, >60% RH) and hot-dry (HD; 43 degrees C-48 degrees C, <25% RH) environments until heat stress became uncompensable. For each condition, we compared heat storage (S) and the change in gastrointestinal temperature (DTgi) over time during compensable and uncompensable heat stress. In addition, we examined whether individual characteristics or seasonality were associated with the rate of increase in Tgi. During compensable heat stress, S was higher in HD than in WH environments (P < 0.05) resulting in a greater but more variable DTgi (P > 0.06) for both metabolic rates. There were no differences among conditions during uncompensable heat stress (all P > 0.05). There was no influence of sex, aerobic fitness, or seasonality, but a larger body size was associated with a greater DTgi during LightAmb in WH (P = 0.003). The slopes of the Tgi response during compensable (WH: MinAct, 0.06, LightAmb, 0.09; HD: MinAct, 0.12, LightAmb, 0.15 degrees C/h) and uncompensable (WH: MinAct, 0.74, LightAmb, 0.87; HD: MinAct, 0.71, LightAmb, 0.93 degrees C/h) heat stress can be used to estimate the time to reach a target core temperature from any given starting value.NEW & NOTEWORTHY This study is the first to examine heat storage and the rate of change in core temperature above (uncompensable heat stress) and just below (compensable heat stress) critical environmental limits to human heat balance. Furthermore, we examine the influence of individual subject characteristics and seasonality on the change in core temperature in warm-humid versus hot-dry environments. We provide the rate of change in core temperature, enabling projections to be made to and from any hypothetical core temperature.
引用
收藏
页码:1011 / 1018
页数:8
相关论文
共 29 条
[1]   Compendium of Physical Activities: an update of activity codes and MET intensities [J].
Ainsworth, BE ;
Haskell, WL ;
Whitt, MC ;
Irwin, ML ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
Bassett, DR ;
Schmitz, KH ;
Emplaincourt, PO ;
Jacobs, DR ;
Leon, AS .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S498-S516
[2]   ADAPTIVE MODIFICATIONS IN THERMOREGULATORY SYSTEM OF LONG-DISTANCE RUNNERS [J].
BAUM, E ;
BRUCK, K ;
SCHWENNICKE, HP .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (03) :404-410
[3]   Validity and reliability of a protocol to establish human critical environmental limits (PSU HEAT Project) [J].
Cottle, Rachel M. ;
Wolf, S. Tony ;
Lichter, Zachary S. ;
Kenney, W. Larry .
JOURNAL OF APPLIED PHYSIOLOGY, 2022, 132 (02) :334-339
[4]   Cutaneous blood flow during exercise is higher in endurance-trained humans [J].
Fritzsche, RG ;
Coyle, EF .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (02) :738-744
[5]   Thermoregulatory responses to exercise: relative versus absolute intensity [J].
Gant, N ;
Williams, C ;
King, J ;
Hodge, BJ .
JOURNAL OF SPORTS SCIENCES, 2004, 22 (11-12) :1083-1090
[6]   Metabolic cost in healthy fit older adults and young adults during overground and treadmill walking [J].
Gupta, Sauvik Das ;
Bobbert, Maarten ;
Faber, Herre ;
Kistemaker, Dinant .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (10) :2787-2797
[7]   Human surface to mass ratio and core temperature in exercise heat stress - a concept revisited [J].
Havenith, G .
JOURNAL OF THERMAL BIOLOGY, 2001, 26 (4-5) :387-393
[8]   Reference Standards for Cardiorespiratory Fitness Measured With Cardiopulmonary Exercise Testing: Data From the Fitness Registry and the Importance of Exercise National Database [J].
Kaminsky, Leonard A. ;
Arena, Ross ;
Myers, Jonathan .
MAYO CLINIC PROCEEDINGS, 2015, 90 (11) :1515-1523
[9]   PHYSIOLOGIC LIMITS TO WORK IN HEAT AND EVAPORATIVE COEFFICIENT FOR WOMEN [J].
KAMON, E ;
AVELLINI, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (01) :71-76
[10]   PHYSIOLOGICAL AND BIOPHYSICAL LIMITS TO WORK IN HEAT FOR CLOTHED MEN AND WOMEN [J].
KAMON, E ;
AVELLINI, B ;
KRAJEWSKI, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1978, 44 (06) :918-925