Improvement of photon collection uniformity from an NE213 scintillator using a light guide

被引:5
作者
Harano, H [1 ]
Matsumoto, T [1 ]
Shibata, Y [1 ]
Ito, Y [1 ]
Uritani, A [1 ]
Kudo, K [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058568, Japan
关键词
energy resolution; light guide; NE213; scintillator; photon collection uniformity; pulse shape discrimination;
D O I
10.1109/TNS.2005.862926
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The uniformity in collecting scintillation photons to the photomultiplier is one of the key parameters to carry out precise measurement using scintillators. A simple method is proposed to improve the collection uniformity of the scintillation photons just by inserting a light guide between a scintillator and a photomultiplier where the sidewall of the light guide is surrounded by a black paper as a photon absorber. This light guide insertion is expected to have a function to reduce the collection efficiency of the scintillation photons generated closer to the photomultiplier due to the larger transmission loss, since a decrease of the angle of incidence raises the fraction of the photons escaping from the sidewall of the light guide. The experiments using an NE213 liquid organic scintillation detector and gamma-ray sources revealed that the light guide functioned as a compensator for the original tendency of the photon collection and improved the photon collection uniformity. The details of the physical mechanism were examined by simulating the behavior of the gamma rays using the EGS4 electron-photon transport Monte Carlo code and the light propagation process using the ray-tracing program GuideM. The effects of the light guide were also examined on the whole energy resolution and the discrimination capability to separate gamma rays and neutrons.
引用
收藏
页码:3147 / 3150
页数:4
相关论文
共 14 条
[1]   A study of the characteristics of scintillation detectors with a diffuse reflector [J].
Baranov, VA ;
Filchenkov, VV ;
Konin, AD ;
Zhuk, VV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (03) :335-340
[2]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[3]   CHARACTERISTICS OF LARGE VOLUME NE213 NEUTRON COUNTERS FOR MUON CATALYZED FUSION INVESTIGATIONS [J].
BYSTRITSKY, VM ;
WOZNIAK, J ;
ZINOV, VG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (2-3) :532-538
[4]   GAMMA-CALIBRATION OF NE-213 SCINTILLATION-COUNTERS [J].
DIETZE, G ;
KLEIN, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 193 (03) :549-556
[5]   STUDY OF THE PARAMETERS OF A LONG NE213 SCINTILLATOR COUNTER [J].
FILCHENKOV, VV ;
KONIN, AD ;
ZINOV, VG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 245 (2-3) :490-494
[6]   Characterization of gamma rays existing in the NMIJ standard neutron field [J].
Harano, H ;
Matsumoto, T ;
Ito, Y ;
Uritani, A ;
Kudo, K .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :69-72
[7]   Neutron and photon spectrometry with liquid scintillation detectors in mixed fields [J].
Klein, H ;
Neumann, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2) :132-142
[8]   THIOBACILLUS-FERROOXIDANS AND THE FORMATION OF ACIDITY IN SIMULATED COAL-MINE ENVIRONMENTS [J].
KLEINMANN, RLP ;
CRERAR, DA .
GEOMICROBIOLOGY JOURNAL, 1979, 1 (04) :373-388
[9]   Photon spectrometry in thermal neutron standard field [J].
Kudo, K ;
Takeda, N ;
Koshikawa, S ;
Toyokawa, H ;
Ohgaki, H ;
Matzke, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2) :213-217
[10]   LIGHT ATTENUATION IN SCINTILLATION COUNTERS [J].
KUIJPER, P ;
TIESINGA, CJ ;
JONKER, CC .
NUCLEAR INSTRUMENTS & METHODS, 1966, 42 (01) :56-+