Fiber type of optical coherence tomography with an auto-focus device

被引:1
|
作者
Lo, YL [1 ]
Yen, CC
Chen, SJ
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 70101, Taiwan
[2] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 70101, Taiwan
关键词
optical coherence tomography; auto-focus device; refractive index; thickness;
D O I
10.1016/j.optcom.2005.08.050
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) is a novel technique for non-invasive imaging based on low coherence interferometer. In this study, we develop a new optical fiber type of OCT with a commercial auto-focus device to simultaneously measure the refractive index and thickness of a single-layer for demonstration. An auto-focus device can be easily implemented into the new OCT in order to diminish the measurement error resulting from the slight vibration of the sample and/or the sample stage. However, if the conventional OCT is implemented with an auto-focus device, it would be extremely difficult in locating and controlling the positions of the sample and scanning stages. From the experimental results, the error percentage from various frequency of the simulated noise is almost under 0.4%. Due to the resonance frequency of a DVD pickup head is around 40 Hz, the error percentage is apparently highest up to 1%; however still acceptable. It is concluded that the auto-focus device indeed works in an OCT system. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [41] Optical coherence tomography in multiple sclerosis
    Woelbert, M.
    Brandt, A. U.
    Paul, F.
    Schippling, S.
    NERVENHEILKUNDE, 2011, 30 (07) : 493 - 497
  • [42] Optical coherence tomography angiography in glaucoma
    Hong, Jimmy
    Tan, Shayne S.
    Chua, Jacqueline
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (02) : 110 - 121
  • [43] Optical coherence tomography in multiple sclerosis
    Vidal-Jordana, Angela
    Sastre-Garriga, Jaume
    Montalban, Xavier
    REVISTA DE NEUROLOGIA, 2012, 54 (09) : 556 - 563
  • [44] Transmission Optical Coherence Tomography Sensing
    Trull, A. K.
    van der Horst, J.
    Bijster, J. G.
    Kalkman, J.
    OPTICAL SENSING AND DETECTION IV, 2016, 9899
  • [45] Optical biometry in a commercially available anterior and posterior segment optical coherence tomography device
    Kanclerz, Piotr
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (05) : 533 - 534
  • [46] Optical Coherence Tomography in Multiple Sclerosis
    Graves, Jennifer S.
    SEMINARS IN NEUROLOGY, 2019, 39 (06) : 711 - 717
  • [47] Analysis of speckle in optical coherence tomography
    An, Y
    Yao, JQ
    Wang, RK
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 245 - 250
  • [48] Optical coherence tomography of the retina in schizophrenia: Inter-device agreement and relations with perceptual function
    Miller, Margaret
    Zemon, Vance
    Nolan-Kenney, Rachel
    Balcer, Laura J.
    Goff, Donald C.
    Worthington, Michelle
    Hasanaj, Lisena
    Butler, Pamela D.
    SCHIZOPHRENIA RESEARCH, 2020, 219 : 13 - 18
  • [49] Optimization of Large-Core-Fiber-Based Fiber Probe for Optical Coherence Tomography
    Qiu Jianrong
    Yang Chen
    Zhang Cheng
    Meng Jia
    Han Tao
    Qian Huanghe
    Chen Peizhe
    Yang Lu
    Liu Zhiyi
    Ding Zhihua
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (20):
  • [50] Optical coherence tomography
    Testoni, Pier Alberto
    THESCIENTIFICWORLDJOURNAL, 2007, 7 : 87 - 108