Performance evaluation of multi-material electronic cleansing for ultra-low-dose dual-energy CT colonography

被引:0
作者
Tachibana, Rie [1 ,2 ,3 ]
Kohlhase, Nadja [2 ,3 ]
Naeppi, Janne J. [2 ,3 ]
Hironaka, Toru [2 ,3 ]
Ota, Junko [4 ]
Ishida, Takayuki [4 ]
Regge, Daniele [5 ]
Yoshida, Hiroyuki [2 ,3 ]
机构
[1] Inst Natl Coll Technol, Dept Informat Sci & Technol, 1091-1 Komatsu Suo Oshima, Oshima 7422193, Japan
[2] Massachusetts Gen Hosp, Dept Radiol, Imaging Res 3D, 25 New Chardon St,Suite 400C, Boston, MA 02114 USA
[3] Harvard Med Sch, 25 New Chardon St,Suite 400C, Boston, MA 02114 USA
[4] Osaka Univ, Dept Med Phys & Engn, 1-7 Yamadaoka, Suita, Osaka 5650871, Japan
[5] Inst Canc Res & Treatment, Candiolo Str Prov 142, IT-10060 Turin, Italy
来源
MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS | 2015年 / 9785卷
关键词
Colon; electronic cleansing; virtual cleansing; ultra-low-dose; dual-energy CT; virtual colonoscopy; random forest; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.2217140
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Accurate electronic cleansing (EC) for CT colonography (CTC) enables the visualization of the entire colonic surface without residual materials. In this study, we evaluated the accuracy of a novel multi-material electronic cleansing (MUMA-EC) scheme for non-cathartic ultra-low-dose dual-energy CTC (DE-CTC). The MUMA-EC performs a water-iodine material decomposition of the DE-CTC images and calculates virtual monochromatic images at multiple energies, after which a random forest classifier is used to label the images into the regions of lumen air, soft tissue, fecal tagging, and two types of partial-volume boundaries based on image-based features. After the labeling, materials other than soft tissue are subtracted from the CTC images. For pilot evaluation, 384 volumes of interest (VOIs), which represented sources of subtraction artifacts observed in current EC schemes, were sampled from 32 ultra-low-dose DE-CTC scans. The voxels in the VOIs were labeled manually to serve as a reference standard. The metric for EC accuracy was the mean overlap ratio between the labels of the reference standard and the labels generated by the MUMA-EC, a dual-energy EC (DE-EC), and a single-energy EC (SE-EC) scheme. Statistically significant differences were observed between the performance of the MUMA/DE-EC and the SE-EC methods (p < 0.001). Visual assessment confirmed that the MUMA-EC generated less subtraction artifacts than did DE-EC and SE-EC. Our MUMA-EC scheme yielded superior performance over conventional SE-EC scheme in identifying and minimizing subtraction artifacts on non-cathartic ultra-low-dose DE-CTC images.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY
    ALVAREZ, RE
    MACOVSKI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) : 733 - 744
  • [2] Random forests
    Breiman, L
    [J]. MACHINE LEARNING, 2001, 45 (01) : 5 - 32
  • [3] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [4] Structure-analysis method for electronic cleansing in cathartic and noncathartic CT colonography
    Cai, Wenli
    Zalis, Michael E.
    Naeppi, Janne
    Harris, Gordon J.
    Yoshida, Hiroyuki
    [J]. MEDICAL PHYSICS, 2008, 35 (07) : 3259 - 3277
  • [5] Cai WL, 2012, IEEE ENG MED BIO, P3736, DOI 10.1109/EMBC.2012.6346779
  • [6] Dual-Energy Based Spectral Electronic Cleansing in Non-Cathartic Computed Tomography Colonography: An Emerging Novel Technique
    Eliahou, Ruth
    Azraq, Yusef
    Carmi, Raz
    Mahgerefteh, Shmuel Y.
    Sosna, Jacob
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (04) : 309 - 314
  • [7] Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: A joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology
    Levin, Bernard
    Lieberman, David A.
    McFarland, Beth
    Andrews, Kimberly S.
    Brooks, Durado
    Bond, John
    Dash, Chiranjeev
    Giardiello, Francis M.
    Glick, Seth
    Johnson, David
    Johnson, C. Daniel
    Levin, Theodore R.
    Pickhardt, Perry J.
    Rex, Douglas K.
    Smith, Robert A.
    Thorson, Alan
    Winawer, Sidney J.
    [J]. GASTROENTEROLOGY, 2008, 134 (05) : 1570 - 1595
  • [8] Lu L, 2013, LECT NOTES COMPUT SC, V8184, P57, DOI 10.1007/978-3-319-02267-3_8
  • [9] Bowel preparation for CT colonography
    Neri, Emanuela
    Lefere, Philippe
    Gryspeerdt, Stefaan
    Bemi, Pietro
    Mantarro, Annalisa
    Bartolozzi, Carlo
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : 1137 - 1143
  • [10] Electronic cleansing and stool tagging in CT colonography: Advantages and pitfalls with primary three-dimensional evaluation
    Pickhardt, PJ
    Choi, JHR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) : 799 - 805