Numerical study of the effect of flow nonuniformities on the low-pressure side of a Cooled Cooling Air heat exchanger

被引:7
作者
Pandey, Sudhanshu [1 ]
Kallath, Hariharan [1 ]
Choi, Ho Yeon [2 ]
Sibilli, Thierry [3 ]
Min, June Kee [1 ]
Chetwynd-Chatwin, Jason [4 ]
Ha, Man Yeong [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, 2, Busandaehak ro 63beon gil, Pusan, South Korea
[2] Air Solut R&D Lab, LG Elect, Gyeongnam, South Korea
[3] SAFRAN SA, Dept Energy & Prop, Safran Tech, Magny les hameaux, France
[4] Rolls Royce plc, Whittle House,POB 3, Bristol BS34 7QE, England
关键词
Cooled Cooling Air; Flow nonuniformity; Heat exchanger; Numerical simulation; MODEL; DROP;
D O I
10.1016/j.applthermaleng.2022.119113
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Cooled Cooling Air (CCA) heat exchanger is a precooler that cools the bleed air from the compressor stages and is located inside the bypass duct of the aeroengine. Nonuniform flows enter the core of the heat exchanger because the cold side is the off-take from the fan flow, compromising its aerothermal performance. These aspects has been disregarded in the literature until now. In this study, the aerothermal performance of a CCA heat exchanger with flow nonuniformities on its Low-Pressure (LP) side is investigated. Three-wire meshes were designed using correlations from the literature, showing three off-design cases, namely, Cases 1, 2, and 3. The porous media and dual cell heat exchanger models were used in numerical simulations for the baseline and off-design cases. Experiments were performed at hot and cold conditions to validate the numerical simulations under actual gas turbine operating conditions. It has been found that heat transfer rate increases in Case 1 and 2 by 1.0% and 1.5%, as the flow non-uniformity is symmetric with respect to XZ plane. In contrast, in Case 3, the heat transfer rate reduces by 4.2% because the flow non-uniformity is asymmetric with respect to XZ plane, inducing cross-flows immediately upstream of the heat exchanger core.
引用
收藏
页数:13
相关论文
共 27 条
  • [1] Ansys, 2017, 12.0 Theory Guide
  • [2] Boyle RJ, 2009, PROCEEDINGS OF ASME TURBO EXPO 2009, VOL 4, P495
  • [3] Bruening G.B., 1999, TURBO EXPO POWER LAN, V3, DOI [10.1115/99-GT-014,V003T01A002, DOI 10.1115/99-GT-014,V003T01A002]
  • [4] Elango P., 2016, P ROYAL AER SOC APPL
  • [5] Elovic E., 1981, Patent, Patent No. [US4254618A, 4254618]
  • [6] Herring NR., 2006, ASME International Mechanical Engineering Congress and Exposition, V47853, P467, DOI DOI 10.1115/IMECE2006-14920
  • [7] Numerical Study of the Flow Uniformity Inside the High-Pressure Side Manifolds of a Cooled Cooling Air Heat Exchanger
    Kallath, Hariharan
    Kholi, Foster Kwame
    Jin, Qingye
    Ha, Man Yeong
    Park, Sang Hu
    Kim, Hyeon-jun
    Chetwynd-Chatwin, Jason
    Min, June Kee
    [J]. APPLIED THERMAL ENGINEERING, 2021, 189
  • [8] Manufacturing and mechanical evaluation of cooled cooling air (CCA) heat exchanger for aero engine
    Kim, Chang-Soo
    Kim, Hyeon-Jun
    Cho, Jong-Rae
    Park, Sang-Hu
    Ha, Man-Yeong
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2016, 17 (09) : 1195 - 1200
  • [9] Kim J., 2016, THESIS PUSAN NATL U
  • [10] Compound porous media model for simulation of flat top U-tube compact heat exchanger
    Kim, Jaemin
    Sibilli, Thierry
    Ha, Man Yeong
    Kim, Kuisoon
    Yoon, Sang Youl
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 138 : 1029 - 1041