Discrepancies in determination of abdominal aortic aneurysms maximum diameter and growth rate, using axial and orhtogonal computed tomography measurements

被引:19
作者
Kontopodis, Nikolaos [1 ]
Metaxa, Eleni [2 ]
Gionis, Michalis [1 ]
Papaharilaou, Yannis [2 ]
Ioannou, Christos V. [1 ]
机构
[1] Univ Crete, Sch Med, Dept Vasc Surg, Iraklion 71110, Greece
[2] Fdn Res & Technol Hellas, Inst Appl & Computat Math, Iraklion, Crete, Greece
关键词
Aortic aneurysm; Computed tomography imaging; Follow-up; Aneurysm enlargement;
D O I
10.1016/j.ejrad.2013.04.031
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Maximum diameter and growth rate of abdominal aortic aneurysms (AAAs) which are currently used as the only variables to set the indication for elective repair are recorded through computed tomography (CT) measurements on an axial plane or on an orthogonal plane that is perpendicular to vessel centerline, interchangeably. We will attempt to record possible discrepancies between the two methods, identify whether such differences could influence therapeutic decisions and determine in which cases this should be expected. Materials and methods: We retrospectively reviewed sixty CT-scans performed in thirty-nine patients. Three-dimensional reconstruction of AAAs has been performed and differences in maximum diameter measured on axial and orthogonal planes were recorded. A measure for asymmetry was introduced termed Shapelndex defined as the value of section minor over major axis and was related with differences in maximum diameter recordings. Growth rates were also determined using both axial and orthogonal measurements. Results: Axial measurements overestimate maximum diameter by 2 +/- 2.7 mm (P < 0.001) with a range of 0-12.3 mm. Overall, 20% of the CTs had an axial maximum diameter >5.5 cm indicating the need for intervention whereas, orthogonal diameter was below that threshold. Asymmetry of the axial sections with Shapelndex <= 0.8 was found to be related to an overestimation of maximum diameter by >5 mm. There were no significant differences in growth rates when determined using orthogonal or axial measurements in both examinations (median growth rate: 2.3 mm and 3.3 mm respectively P = 0.2). However there were significant differences when orthogonal measurements were used at initial and axial measurements used at follow-up examination or vice versa (median growth rate: 4.9 mm and 0.9 mm respectively P < 0.001). Conclusions: Although the mean difference between measurements is low there is a wide range among cases, mainly observed in asymmetrical AAAs. Shapelndex may identify those which are more likely to be misestimated. CT measurements performed to establish AAA growth rates should consistently use either the axial or orthogonal technique to avoid inaccuracies from occurring. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1398 / 1403
页数:6
相关论文
共 13 条
  • [1] Community and hospital outcome from ruptured abdominal aortic aneurysm within the catchment area of a regional vascular surgical service
    Adam, DJ
    Mohan, IV
    Stuart, WP
    Bain, M
    Bradbury, AW
    [J]. JOURNAL OF VASCULAR SURGERY, 1999, 30 (05) : 922 - 928
  • [2] [Anonymous], 1995, Eur J Vasc Endovasc Surg, V9, P42
  • [3] Robust and objective decomposition and mapping of bifurcating vessels
    Antiga, L
    Steinman, DA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (06) : 704 - 713
  • [4] Reporting standards for endovascular aortic aneurysm repair
    Chaikof, EL
    Blankensteijn, JD
    Harris, PL
    White, GH
    Zarins, CK
    Bernhard, VM
    Matsumura, JS
    May, J
    Veith, FJ
    Fillinger, MF
    Rutherford, RB
    Kent, KC
    [J]. JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) : 1048 - 1060
  • [5] Georgakarakos E, 2009, INT ANGIOL, V28, P325
  • [6] Hirsch AT, 2006, CIRCULATION, V113, pE463, DOI 10.1161/CIRCULATIONAHA.106.174526
  • [7] DESIGN OF THE ABDOMINAL AORTIC-ANEURYSM DETECTION AND MANAGEMENT STUDY
    LEDERLE, FA
    WILSON, SE
    JOHNSON, GR
    LITTOOY, FN
    ACHER, C
    MESSINA, LM
    REINKE, DB
    BALLARD, DJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 20 (02) : 296 - 303
  • [8] The aneurysm detection and management study screening program - Validation cohort and final results
    Lederle, FA
    Johnson, GR
    Wilson, SE
    Chute, EP
    Hye, RJ
    Makaroun, MS
    Barone, GW
    Bandyk, D
    Moneta, GL
    Makhoul, RG
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2000, 160 (10) : 1425 - 1430
  • [9] Abdominal aortic aneurysm diameter: A comparison of ultrasound measurements with those from standard and three-dimensional computed tomography reconstruction
    Manning, Brian J.
    Kristmundsson, Thorarinn
    Sonesson, Bjorn
    Resch, Timothy
    [J]. JOURNAL OF VASCULAR SURGERY, 2009, 50 (02) : 263 - 268
  • [10] Minino Arialdi M, 2007, Natl Vital Stat Rep, V55, P1