The role of fluoroscopy in cervical epidural steroid injections - An analysis of contrast dispersal patterns

被引:114
|
作者
Stojanovic, MP
Vu, TN
Caneris, O
Slezak, J
Cohen, SP
Sang, CN
机构
[1] Massachusetts Gen Hosp, Dept Anesthesia & Crit Care, MGH Pain Ctr, Intervent Pain Program, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Massachusetts Gen Hosp, Clin Trials Program, MGH Pain Ctr, Boston, MA 02114 USA
[4] NE Rehabil Hosp, Salem, NH USA
[5] NE Pain Consultants, Somersworth, NH USA
关键词
injection epidural; steroids; fluoroscopy;
D O I
10.1097/00007632-200203010-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A multicenter, retrospective analysis of cervical epidurograms. Objectives. To determine the effectiveness of the loss of resistance (LOR) technique in identifying the cervical epidural space. To delineate the pattern of epidural contrast spread during cervical epidural steroid injections. Background. Previous studies have shown that if performed without fluoroscopy, the LOR technique can result in inaccurate needle placement in up to 30% of lumbar epidural steroid injections. To date, no study has examined accuracy of LOR technique and pattern of radiographic contrast spread in cervical epidural levels. Methods. Epidurograms of 38 cervical epidural steroid injections in 31 patients were reviewed. The number of LOR attempts and pattern of contrast spread was analyzed. The effects of age, gender, MRI results, previous cervical laminectomy, and the physician's level of training were correlated with results. Results. The authors found a 53% rate of false LOR during the first attempt to enter the epidural space. Unilateral epidural contrast spread was found in 51% and ventral epidural spread was found in 28% of cases. The average number of cervical vertebral levels covered with 2 mL of contrast was 3.14, with significantly wider spread noted in those patients who had not undergone previous cervical laminectomy. Other variables did not influence the accuracy of needle placement and pattern of epidural contrast spread. Conclusions. The loss of resistance technique may not be an adequate method for ensuring accurate needle placement in blindly performed cervical epidural injections. The use of epidurography can improve the accuracy of needle placement and medication delivery to targeted areas of pathology.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 33 条
  • [21] Needle Entry Angle to Prevent Carotid Sheath Injury for Fluoroscopy-Guided Cervical Transforaminal Epidural Steroid Injection
    Choi, Jaewoo
    Ha, Doo Hoe
    Kwon, Shinyoung
    Jung, Youngsu
    Yu, Junghoon
    Kim, MinYoung
    Min, Kyunghoon
    ANNALS OF REHABILITATION MEDICINE-ARM, 2018, 42 (06): : 814 - 821
  • [22] Reducing Radiation Exposure in Lumbar Transforaminal Epidural Steroid Injections with Pulsed Fluoroscopy: A Randomized, Double-blind, Controlled Clinical Trial
    Braun, Edward
    Sack, Andrew M.
    Sayed, Dawood
    Manion, Smith
    Hamm, Brian
    Brimacombe, Michael
    Tollette, Michael
    Khan, Talal W.
    Orr, Walter
    Nicol, Andrea
    PAIN PHYSICIAN, 2018, 21 (01) : 53 - 60
  • [23] Correlation between Epidurographic Contrast Flow Patterns and Clinical Effectiveness in Chronic Lumbar Discogenic Radicular Pain Treated with Epidural Steroid Injections Via Different Approaches
    Gupta, Ruchi
    Singh, Saru
    Kaur, Sukhdeep
    Singh, Kulvinder
    Aujla, Kuljeet
    KOREAN JOURNAL OF PAIN, 2014, 27 (04) : 353 - 359
  • [24] Anomalous Location of the Vertebral Artery in Relation to the Neural Foramen. Implications for Cervical Transforaminal Epidural Steroid Injections
    Beckworth, William Jeremy
    Sood, Rajiv
    Katzer, Arin Fredrick
    Wu, Baohua
    PAIN MEDICINE, 2013, 14 (08) : 1119 - 1125
  • [25] Contrast Dispersion Pattern and Efficacy of Computed Tomography-Guided Cervical Transforaminal Epidural Steroid Injection
    Park, Chan Hong
    Lee, Sang-Ho
    PAIN PHYSICIAN, 2014, 17 (06) : 487 - 492
  • [26] Unintentional lumbar facet joint injection guided by fluoroscopy during interlaminar epidural steroid injection: a retrospective analysis
    Kim, Min Jae
    Choi, Yun Suk
    Suh, Hae Jin
    Kim, You Jin
    Noh, Byeong Jin
    KOREAN JOURNAL OF PAIN, 2018, 31 (02) : 87 - 92
  • [27] Distribution Range of Cervical Interlaminar Epidural Injections: A Comparative Study with 2.5 mL, 5 mL, and 10 mL of Contrast
    Lee, Sang Eun
    Joe, Han Bum
    Park, Jae Hong
    Yi, In Kyong
    Choi, Yi Hwa
    Han, Kyung Ream
    Kim, Chan
    PAIN PHYSICIAN, 2013, 16 (02) : 155 - 164
  • [28] Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit
    Choi, Eun Joo
    Go, Gwangcheol
    Han, Woong Ki
    Lee, Pyung-Bok
    KOREAN JOURNAL OF PAIN, 2020, 33 (01) : 73 - 80
  • [29] Radicular Pain Management Using Ultrasound-Guided Versus Fluoroscopy-Guided Epidural Steroid Injections: A Systematic Scoping Review of Comparative Studies
    Hassan, Wassim
    Hassan, Ahmad
    Ablordeppey, Enyo
    Mustafa, Jabra
    Yaeger, Lauren
    Al-Busaidi, Ibrahim S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [30] Facet Joint Versus Transforaminal Epidural Steroid Injections in Patients With Cervical Radicular Pain due to Foraminal Stenosis: A Retrospective Comparative Study
    Chae, Ji Seon
    Kim, Won-Joong
    Jue, Mi Jin
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2022, 37 (25)