On-line simultaneous and rapid separation of anions and cations from a single sample using dual-capillary sequential injection-capillary electrophoresis

被引:58
作者
Gaudry, Adam J. [1 ]
Guijt, Rosanne M. [2 ]
Macka, Mirek [1 ]
Hutchinson, Joseph P. [1 ]
Johns, Cameron [1 ]
Hilder, Emily F. [1 ]
Dicinoski, Greg W. [1 ]
Nesterenko, Pavel N. [1 ]
Haddad, Paul R. [1 ]
Breadmore, Michael C. [1 ]
机构
[1] Univ Tasmania, Fac Sci Engn & Technol, Sch Chem, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Sch Pharm, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
基金
澳大利亚研究理事会;
关键词
Simultaneous anion and cation separation; Capillary electrophoresis; Sequential injection; CONTACTLESS CONDUCTIVITY DETECTION; IMPROVISED EXPLOSIVE DEVICES; INORGANIC ANIONS; EXCHANGE CHROMATOGRAPHY; ZONE-ELECTROPHORESIS; ION CHROMATOGRAPHY; POSTBLAST RESIDUES; IDENTIFICATION; INSTRUMENTATION; FLOW;
D O I
10.1016/j.aca.2013.03.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel capillary electrophoresis (CE) approach has been developed for the simultaneous rapid separation and identification of common environmental inorganic anions and cations from a single sample injection. The method utilised a sequential injection-capillary electrophoresis instrument (SI-CE) with capacitively-coupled contactless conductivity detection ((CD)-D-4) constructed in-house from commercial-off-the-shelf components. Oppositely charged analytes from a single sample plug were simultaneously injected electrokinetically onto two separate capillaries for independent separation and detection. Injection was automated and may occur from a syringe or be directly coupled to an external source in a continuous manner. Software control enabled high sample throughput (17 runs per hour for the target analyte set) and the inclusion of an isolation valve allowed the separation capillaries to be flushed, increasing throughput by removing slow migrating species as well as improving repeatability. Various environmental and industrial samples (subjected only to filtering) were analysed in the laboratory with a 3 min analysis time which allowed the separation of 23 inorganic and small organic anions and cations. Finally, the system was applied to an extended automated analysis of Hobart Southern Water tap water for a period of 48 h. The overall repeatability of the migration times of a 14 analyte standard sample was less than 0.74% under laboratory conditions. LODs ranged from 5 to 61 mu g L-1. The combination of automation, high confidence of peak identification, and low limits of detection make this a useful system for the simultaneous identification of a range of common inorganic anions and cations for discrete or continuous monitoring applications. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 25 条
[1]   SEPARATION OF NON UV-ABSORBING CATIONS BY CAPILLARY ELECTROPHORESIS [J].
BECK, W ;
ENGELHARDT, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :618-621
[2]   Identification of Inorganic Improvised Explosive Devices Using Sequential Injection Capillary Electrophoresis and Contactless Conductivity Detection [J].
Blanco, Gustavo A. ;
Nai, Yi H. ;
Hilder, Emily F. ;
Shellie, Robert A. ;
Dicinoski, Greg W. ;
Haddad, Paul R. ;
Breadmore, Michael C. .
ANALYTICAL CHEMISTRY, 2011, 83 (23) :9068-9075
[3]   Simultaneous determination of inorganic anions and cations by capillary electrophoresis with indirect UV detection [J].
Haumann, I ;
Boden, J ;
Mainka, A ;
Jegle, U .
JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) :269-277
[4]   A novel method for analysis of explosives residue by simultaneous detection of anions and cations via capillary zone electrophoresis [J].
Hopper, KG ;
LeClair, H ;
McCord, BR .
TALANTA, 2005, 67 (02) :304-312
[5]   Identification of inorganic improvised explosive devices by analysis of postblast residues using portable capillary electrophoresis instrumentation and indirect photometric detection with a light-emitting diode [J].
Hutchinson, Joseph P. ;
Evenhuis, Christopher J. ;
Johns, Cameron ;
Kazarian, Artaches A. ;
Breadmore, Michael C. ;
Macka, Miroslav ;
Hilder, Emily F. ;
Guijt, Rosanne M. ;
Dicinoski, Greg W. ;
Haddad, Paul R. .
ANALYTICAL CHEMISTRY, 2007, 79 (18) :7005-7013
[6]   Identification of inorganic ions in post-blast explosive residues using portable CE instrumentation and capacitively coupled contactless conductivity detection [J].
Hutchinson, Joseph P. ;
Johns, Cameron ;
Breadmore, Michael C. ;
Hilder, Emily F. ;
Guijt, Rosanne M. ;
Lennard, Chris ;
Dicinoski, Greg ;
Haddad, Paul R. .
ELECTROPHORESIS, 2008, 29 (22) :4593-4602
[7]   Simultaneous separation of anions and cations by capillary electrophoresis with high magnitude, reversed electroosmotic flow [J].
Johns, C ;
Yang, WC ;
Macka, M ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1050 (02) :217-222
[8]   A flow injection-capillary electrophoresis system with high-voltage contactless conductivity detection for automated dual opposite end injection [J].
Kubán, P ;
Kubán, P ;
Hauser, PC ;
Kubán, V .
ELECTROPHORESIS, 2004, 25 (01) :35-42
[9]  
Kubán P, 2002, ELECTROPHORESIS, V23, P3725, DOI 10.1002/1522-2683(200211)23:21<3725::AID-ELPS3725>3.0.CO
[10]  
2-9