Diffusion tensor imaging and fiber tractography of the median nerve at 1.5T: optimization of b value

被引:39
|
作者
Andreisek, Gustav
White, Lawrence M.
Kassner, Andrea [1 ]
Tomlinson, George [2 ]
Sussman, Marshall S. [3 ]
机构
[1] Univ Toronto, Univ Hlth Network, Dept Med Imaging, Toronto, ON M5G 1X5, Canada
[2] Univ Toronto, Toronto Gen Hosp, Div Clin Decis Making & Hlth Care, Dept Publ Hlth Sci, Toronto, ON M5G 2C4, Canada
[3] Univ Toronto, Dept Med Imaging, Toronto Gen Hosp, Toronto, ON M5G 1X5, Canada
关键词
MRI; Diffusion tensor imaging; Fiber tractography; Median nerve; PRINCIPAL EIGENVECTOR MEASUREMENTS; VIVO MR TRACTOGRAPHY; FRACTIONAL ANISOTROPY; MEAN DIFFUSIVITY; NOISE; DTI; TRACKING; REPRODUCIBILITY; VISUALIZATION;
D O I
10.1007/s00256-008-0577-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objective of this study was to systematically assess the optimal b value for diffusion tensor imaging and fiber tractography of the median nerve at 1.5 T. This is a prospective study which was carried out with institutional review board approval and written informed consent from the study subjects. Fifteen healthy volunteers (seven men, eight women; mean age, 31.2 years) underwent diffusion tensor imaging of the wrist. A single-shot spin-echo-based echo-planar imaging sequence (TR/TE, 7000/103 ms) was performed in each subject at eight different b values ranging from 325 to 1,550 s/mm2. Number and length of reconstructed fiber tracts, fiber density index (FDi), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated for the median nerve. Signal-to-noise ratio (SNR) was also calculated for each acquisition. The overall image quality was assessed by two readers in consensus by ranking representative fiber tract images for each subject using a scale range from 1 to 8 (1 = best to 8 = worst image quality). Longest fibers were observed for b values between 675 and 1,025 s/mm2. Maximum FDi was found at b values of 1,025 s/mm2. FA was between 0.5 and 0.6 for all b values. ADC gradually decreased from 1.44 x 10-3 to 0.92 x 10-3 mm2/s with increasing b values. Maximum SNR +/- standard deviation (175.4 +/- 72.6) was observed at the lowest b value and decreased with increasing b values. SNR at b values of 1,025 s/mm2 was 48.5% of the maximum SNR. Optimal fiber tract image quality was found for b values of 1,025 s/mm2. The optimal b value for diffusion tensor imaging and fiber tractography of the median nerve at 1.5 T was 1,025 s/mm2.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 50 条
  • [1] Diffusion tensor imaging and fiber tractography of the median nerve at 1.5T: optimization of b value
    Gustav Andreisek
    Lawrence M. White
    Andrea Kassner
    George Tomlinson
    Marshall S. Sussman
    Skeletal Radiology, 2009, 38 : 51 - 59
  • [2] Diffusion Tensor Imaging and Fiber Tractography of Skeletal Muscle: Optimization of b Value for Imaging at 1.5 T
    Saupe, Nadja
    White, Lawrence M.
    Stainsby, Jeffrey
    Tomlinson, George
    Sussman, Marshall S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (06) : W282 - W290
  • [3] MR neurography of the median nerve at 3.0T: Optimization of diffusion tensor imaging and fiber tractography
    Guggenberger, Roman
    Eppenberger, Patrick
    Markovic, Daniel
    Nanz, Daniel
    Chhabra, Avneesh
    Pruessmann, Klaas P.
    Andreisek, Gustav
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : E775 - E782
  • [4] 3-T MRI with diffusion tensor imaging and tractography of the median nerve
    Céline Barcelo
    Marie Faruch
    Franck Lapègue
    Marie-Aurélie Bayol
    Nicolas Sans
    European Radiology, 2013, 23 : 3124 - 3130
  • [5] 3-T MRI with diffusion tensor imaging and tractography of the median nerve
    Barcelo, Celine
    Faruch, Marie
    Lapegue, Franck
    Bayol, Marie-Aurelie
    Sans, Nicolas
    EUROPEAN RADIOLOGY, 2013, 23 (11) : 3124 - 3130
  • [6] Diffusion tensor imaging and tractography of median nerve:: A normative diffusion values
    Kabakci, Neslihan
    Guerses, Bengi
    Firat, Zeynep
    Bayram, Ali
    Ulug, Aziz Muefit
    Kovanlikaya, Arzu
    Kovanlikaya, Ilami
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) : 923 - 927
  • [7] Optimization of the Parameters for Diffusion Tensor Magnetic Resonance Imaging Data Acquisition for Breast Fiber Tractography at 1.5 T
    Wang, Yuan
    Zhang, Xiao-Peng
    Li, Yan-Ling
    Li, Xiao-Ting
    Hu, Yan
    Cui, Yong
    Sun, Ying-Shi
    Zhang, Xiao-Yan
    CLINICAL BREAST CANCER, 2014, 14 (01) : 61 - 67
  • [8] Diffusion tensor based forearm nerve tractography in 1.5 T MRI
    Zubkov, M.
    Efimtcev, A.
    Trufanov, G.
    Gulko, A.
    Popov, S.
    Orlov, I.
    Slobozhanyuk, A.
    Melchakova, I.
    METANANO 2019, 2020, 1461
  • [9] Evaluation of Diffusion Tensor Imaging and Fiber Tractography of the Median Nerve: Preliminary Results on Intrasubject Variability and Precision of Measurements
    Andreisek, Gustav
    White, Lawrence M.
    Kassner, Andrea
    Sussman, Marshall S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : W65 - W72
  • [10] Diffusion tensor imaging and tractography of the median nerve in carpal tunnel syndrome: preliminary results
    C. Khalil
    C. Hancart
    V. Le Thuc
    C. Chantelot
    D. Chechin
    A. Cotten
    European Radiology, 2008, 18