Glucose monitoring with long-term subcutaneous microdialysis in neonates

被引:41
作者
Baumeister, FAM
Rolinski, B
Busch, R
Emmrich, P
机构
[1] Tech Univ Munich, Childrens Hosp, Childrens Clin, Munich, Germany
[2] Univ Munich, Childrens Hosp, Dr V Hauner Childrens Hosp, D-8000 Munich, Germany
[3] Tech Univ Munich, Dept Med Stat & Epidemiol, D-8000 Munich, Germany
关键词
microdialysis; monitoring; glucose; recovery; neonates;
D O I
10.1542/peds.108.5.1187
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background. Microdialysis is a new approach for continuous monitoring of small molecules in the extracellular space, and hypoglycemia is a common problem in neonatal intensive care. The objective of this study was to evaluate subcutaneous microdialysis for long-term glucose monitoring in neonatal intensive care. We determined the relative recovery of the microdialysis system in vitro and in vivo, the stability of the relative recovery in vivo during long-term microdialysis, and the correlation between blood and dialysate concentrations of glucose and urea. Furthermore, we evaluated the sensitivity and specificy of subcutaneous microdialysis for the diagnosis of hypoglycemia. Patient and Methods. Thirteen infants (10 neonates) with gestational ages of 30.2 to 45.6 weeks were investigated by microdialysis of subcutaneous adipose tissue and blood sampling. Subcutaneous microdialysis was performed for a median (range) duration of 9 (4-16) days. Results. The application was safe, even in extremely low birth weight infants (< 1000 g) with scanty subcutaneous adipose tissue. The mean +/- standard deviation of the relative recovery in vitro was 101 +/- 3% for glucose and 100 +/- 2% for urea. Using urea as the internal standard, the mean relative recovery in vivo was 96.4 +/- 12.7% at the beginning and remained constant up to 16 days. The correlation between microdialysate and blood was significant for glucose (r = 0.88) and urea (r = 0.98). Subcutaneous microdialysis allowed the detection of asymptomatic hypoglycemias. The diagnostic sensitivity of a dialysate glucose <less than or equal to>2.9 mM to predict a blood glucose level less than or equal to2.8 mM was 92.3%, with 88.1% specificy. The positive predictive value with a 13.4% prevalence of a blood glucose < 2.8 mM was 54.5%, with a negative predictive value of 98.7% and an accuracy of 88.7%. Conclusions. Subcutaneous microdialysis is a safe method, well suited for long-term glucose monitoring in neonates during intensive care. Subcutaneous microdialysis can be used to reduce blood loss and painful stress resulting from diagnostic blood sampling in high-risk neonates.
引用
收藏
页码:1187 / 1192
页数:6
相关论文
共 29 条
[1]   MICRODIALYSIS OF ADIPOSE-TISSUE [J].
ARNER, P ;
BOLINDER, J .
JOURNAL OF INTERNAL MEDICINE, 1991, 230 (04) :381-386
[2]   LONG-TERM CONTINUOUS GLUCOSE MONITORING WITH MICRODIALYSIS IN AMBULATORY INSULIN-DEPENDENT DIABETIC-PATIENTS [J].
BOLINDER, J ;
UNGERSTEDT, U ;
ARNER, P .
LANCET, 1993, 342 (8879) :1080-1085
[3]   Self-monitoring of blood glucose in type I diabetic patients: Comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions [J].
Bolinder, J ;
HagstromToft, E ;
Ungerstedt, U ;
Arner, P .
DIABETES CARE, 1997, 20 (01) :64-70
[4]   MICRODIALYSIS MEASUREMENT OF THE ABSOLUTE GLUCOSE-CONCENTRATION IN SUBCUTANEOUS ADIPOSE-TISSUE ALLOWING GLUCOSE MONITORING IN DIABETIC-PATIENTS [J].
BOLINDER, J ;
UNGERSTEDT, U ;
ARNER, P .
DIABETOLOGIA, 1992, 35 (12) :1177-1180
[5]   Controversies regarding definition of neonatal hypoglycemia: Suggested operational thresholds [J].
Cornblath, M ;
Hawdon, JM ;
Williams, AF ;
Aynsley-Green, A ;
Ward-Platt, MP ;
Schwartz, R ;
Kalhan, SC .
PEDIATRICS, 2000, 105 (05) :1141-1145
[6]  
COWETT RM, 1996, PEDIAT ENDOCRINOLOGY, P677
[7]  
DURING MJ, 1994, J NEUROCHEM, V62, P2356
[8]   A METHOD FOR ESTIMATION OF EXTRACELLULAR CONCENTRATION OF COMPOUNDS BY MICRODIALYSIS USING UREA AS AN ENDOGENOUS RECOVERY MARKER IN-VITRO VALIDATION [J].
EISENBERG, EJ ;
EICKHOFF, WM .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1993, 30 (01) :27-31
[9]   Lipolytic response during spontaneous hypoglycaemia in insulin-dependent diabetic subjects [J].
Hagström-Toft, E ;
Hellström, L ;
Moberg, E .
HORMONE AND METABOLIC RESEARCH, 1998, 30 (09) :586-593
[10]   MICRODIALYSIS SAMPLING OF THE NEURONAL ENVIRONMENT IN BASIC AND CLINICAL RESEARCH [J].
HAMBERGER, A ;
JACOBSON, I ;
NYSTROM, B ;
SANDBERG, M .
JOURNAL OF INTERNAL MEDICINE, 1991, 230 (04) :375-380