Automated quality control of brain MR images

被引:42
作者
Gedamu, Elias L. [1 ]
Collins, D. L. [1 ]
Arnold, Douglas L. [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
关键词
automated; quality control; magnetic resonance imaging; computer-assisted image analysis; quantitative evaluation; brain;
D O I
10.1002/jmri.21434
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a novel fully automated method for assessing the quality of magnetic resonance imaging (MRI) data acquired in a clinical trials environment. Materials and Methods: This work was performed in the context of clinical trials for multiple sclerosis. Quality control (QC) procedures included were: (i) patient brain identity verification, (ii) alphanumeric parameter matching, (iii) signal-to-noise ratio estimation, (iv) gadolinium-enhancement verification, and (v) detection of ghosting due to head motion. Each QC procedure produces a quantitative measurement which is compared against an acceptance threshold that was determined based on receiver operating characteristic analysis of traditional manual and visual QC performed by trained experts. Results: The automated QC results have high sensitivity and specificity when compared with the visual QC. Conclusion: Our automated objective QC procedure can replace many manual subjective procedures to provide increased data throughput while reducing reader variability.
引用
收藏
页码:308 / 319
页数:12
相关论文
共 40 条
  • [1] *AM COLL RAD, 2004, ACR MRI QUAL CONTR M
  • [2] American of College Radiology, 2005, PHANT TEST GUID ACR
  • [3] [Anonymous], 1988, MAGN RESON IMAGING, V6, P195
  • [4] [Anonymous], COPLANAR STEROTACTIC
  • [5] Automatic quality assessment protocol for MRI equipment
    Bourel, P
    Gibon, D
    Coste, E
    Daanen, V
    Rousseau, J
    [J]. MEDICAL PHYSICS, 1999, 26 (12) : 2693 - 2700
  • [6] Cerebral atrophy measurements using Jacobian integration: Comparison with the boundary shift integral
    Boyes, Richard G.
    Rueckert, Daniel
    Aljabar, Paul
    Whitwell, Jennifer
    Schott, Jonathan M.
    Hill, Derek L. G.
    Fox, Nicholas C.
    [J]. NEUROIMAGE, 2006, 32 (01) : 159 - 169
  • [7] The Rose model, revisited
    Burgess, AE
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03): : 633 - 646
  • [8] Quality assurance of clinical MRI scanners using ACR MRI phantom: Preliminary results
    Chen, CC
    Wan, YL
    Wai, YY
    Liu, HL
    [J]. JOURNAL OF DIGITAL IMAGING, 2004, 17 (04) : 279 - 284
  • [9] AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE
    COLLINS, DL
    NEELIN, P
    PETERS, TM
    EVANS, AC
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 192 - 205
  • [10] COLLINS DL, 2001, AUTOMATED ESTIMATION