Voltammetric determination of analgesics using a montmorillonite modified electrode

被引:40
作者
Muralidharan, B. [1 ,2 ]
Gopu, G. [1 ]
Vedhi, C. [1 ]
Manisankar, P. [1 ]
机构
[1] Alagappa Univ, Dept Ind Chem, Karaikkudi 630003, Tamil Nadu, India
[2] Birla Inst Technol & Sci Pilani, Dept Chem, Dubai, U Arab Emirates
关键词
Acetaminophen; Acetylsalicylic acid; Dipyrone; Analgesics; Montmorillonite; Voltammetry;
D O I
10.1016/j.clay.2007.11.005
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Three analgesics were studied voltammetrically using a sodium montmorillonite (NaMM) modified glassy carbon electrode. The voltammograms of analgesics were studied in pHs 1.0-13.0. Influence of pH, sweep rate and pharmaceutical formulations concentration were studied. One well-defined oxidation peak was observed for acetaminophen (AAP) and acetylsalicylic acid (ASA), three oxidation peaks for dipyrone (DP). The oxidation peak potential shifted towards negatively with change in pH. The oxidation was irreversible and diffusion-controlled for all pharmaceutical samples of acetaminophen, dipyrone, and acetylsalicylic acid. A systematic study of the experimental parameters that affect the square wave stripping voltammetric response was carried out and optimized conditions were arrived at. Under optimum conditions, stripping voltammetric procedure was developed for the determination of analgesics in pharmaceutical and urine at pH 1.0. A calibration plot was derived and the lower limit of determination was noticed as 0.02 mu g mL(-1) for acetylsalicylic acid, 0.02 mu g mL(-1) for acetaminophen and 0.04 mu g mL(-1) for dipyrone. The percentage Of RSD was also found. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 213
页数:8
相关论文
共 40 条
[1]   Determination of dipyrone in pharmaceutical products by flow injection analysis with potentiometric detection [J].
Albuquerque, JS ;
Silva, VL ;
Lima, F ;
Araújo, AN ;
Montenegro, MCBSM .
ANALYTICAL SCIENCES, 2003, 19 (05) :691-694
[2]  
Andres C., 2000, TALANTA, V53, P417
[3]  
[Anonymous], KMITL SCI TECH J
[4]   Flow injection-Fourier transform infrared spectrometric determination of paracetamol in pharmaceuticals [J].
Bouhsain, Z ;
Garrigues, S ;
delaGuardia, M .
ANALYST, 1996, 121 (05) :635-639
[5]   Salicylic acid determination in cow urine and drugs using a bienzymatic sensor [J].
Campanella, L. ;
Gregori, E. ;
Tomassetti, M. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (01) :94-99
[6]   North of England evidence based guideline development project: guideline on the use of aspirin as secondary prophylaxis for vascular disease in primary care [J].
Eccles, M ;
Freemantle, N ;
Mason, J .
BMJ-BRITISH MEDICAL JOURNAL, 1998, 316 (7140) :1303-1309
[7]   Investigation and comparison of the electrochemical behavior of some organic and biological molecules at various conducting polymer electrodes [J].
Erdogdu, G ;
Karagozler, AE .
TALANTA, 1997, 44 (11) :2011-2018
[8]   Voltammetric determination of paracetamol at C60-modified glassy carbon electrode [J].
Goyal, RN ;
Singh, SP .
ELECTROCHIMICA ACTA, 2006, 51 (15) :3008-3012
[9]   Automatic sequential injection analysis electronic tongue with integrated reference electrode for the determination of ascorbic acid, uric acid and paracetamol [J].
Gutes, Albert ;
Calvo, Daniel ;
Cespedes, Francisco ;
del Valle, Manuel .
MICROCHIMICA ACTA, 2007, 157 (1-2) :1-6
[10]   Dipyrone into the nucleus raphe magnus inhibits the rat nociceptive tail-flick reflex [J].
Jones, SL .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1996, 318 (01) :37-40