Diagnostic performance of multidetector computed tomography for foreign body aspiration in children

被引:26
作者
Manach, Yves [1 ,2 ]
Pierrot, Sebastien [1 ]
Couloigner, Vincent [1 ,2 ]
Ayari-Khalfallah, Sonia [3 ]
Nicollas, Richard [4 ]
Venail, Frederic [5 ]
Pondaven, Soizick [6 ]
Baculard, Florence [7 ]
Tantcheu, Victor [8 ]
机构
[1] Hop Necker Enfants Malad, APHP, Paediat ENT Dept, F-75015 Paris, France
[2] Paris Descartes Univ, F-75006 Paris, France
[3] CHU Lyon, Paediat ENT Dept, FME Hosp, F-69500 Lyon Bron, France
[4] CHU Marseille, Paediat ENT Dept, Timone Hosp, F-13385 Marseille, France
[5] CHU Montpellier, Pediat ENT Dept, Guy de Chaulliac Hosp, F-34295 Montpellier, France
[6] CHU Tours, Paediat ENT Dept, Clocheville Hosp, F-37044 Tours, France
[7] Hop Robert Debre, APHP, Paediat ENT Dept, F-75935 Paris, France
[8] Hop Necker Enfants Malad, APHP, Dept Paediat Radiol, F-75015 Paris, France
关键词
Multidetector computed tomography; Foreign body; Aspiration; Respiratory; Children; Sensitivity and specificity; VIRTUAL BRONCHOSCOPY; PEDIATRIC-PATIENTS; CT; BODIES;
D O I
10.1016/j.ijporl.2013.02.016
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To evaluate the sensitivity of multidetector computed tomography for confirming suspected foreign body aspiration into the airways in children. Method: We conducted a multicentre prospective study of 303 children evaluated using multidetector computed tomography with axial analysis complemented by multiplanar reconstruction when required. The images were read by a radiologist before endoscopy then reviewed later by a senior radiologist blinded to the endoscopy findings. Endoscopy was performed routinely. Results: Foreign bodies were found by endoscopy in 70 of the 303 children. The initial multidetector computed tomography reading was 94% sensitive and 95% specific. For the review, the images for 91 patients were excluded because of motion blurring or absence of larynx visualisation; in the remaining 212 patients, sensitivity was 98% and specificity 97%. Conclusion: Multidetector computed tomography as performed in our patients cannot replace endoscopy, which remains the reference standard. Nevertheless, multidetector. computed tomography is sufficiently sensitive to be of value when foreign body aspiration is not considered initially or when endoscopy is likely to prove challenging. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:808 / 812
页数:5
相关论文
共 50 条
[41]   Predictors of radiolucent foreign body aspiration [J].
Mortellaro, Vincent E. ;
Iqbal, Corey ;
Fu, Roxanna ;
Curtis, Heather ;
Fike, Frankie B. ;
St Peter, Shawn D. .
JOURNAL OF PEDIATRIC SURGERY, 2013, 48 (09) :1867-1870
[42]   Tracheobronchomalacia in pediatric patients with esophageal atresia: Comparison of diagnostic laryngoscopy/bronchoscopy and dynamic airway multidetector computed tomography [J].
Ngerncham, Monawat ;
Lee, Edward Y. ;
Zurakowski, David ;
Tracy, Donald A. ;
Jennings, Russell .
JOURNAL OF PEDIATRIC SURGERY, 2015, 50 (03) :402-407
[43]   Thoracic Multidetector Computed Tomography Findings of Dedicator of Cytokinesis 8 Deficiency in Children [J].
Lee, Edward Y. ;
Vargas, Sara O. ;
Gaffin, Jonathan M. ;
Chou, Janet ;
Park, Halley J. ;
Winant, Abbey J. .
JOURNAL OF THORACIC IMAGING, 2021, 36 (05) :304-309
[44]   Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans [J].
Veldhoen, Simon ;
Schoellchen, Maximilian ;
Hanken, H. ;
Precht, C. ;
Henes, F. O. ;
Schoen, G. ;
Nagel, H. D. ;
Schumacher, U. ;
Heiland, M. ;
Adam, G. ;
Regier, M. .
EUROPEAN RADIOLOGY, 2017, 27 (02) :790-800
[45]   Foreign body aspiration in children [J].
Midulla, F ;
Guidi, R ;
Barbato, A ;
Capocaccia, P ;
Forenza, N ;
Marseglia, G ;
Pifferi, M ;
Moretti, C ;
Bonci, E ;
De Benedictis, FM .
PEDIATRICS INTERNATIONAL, 2005, 47 (06) :663-668
[46]   FOREIGN BODY ASPIRATION IN CHILDREN [J].
Gluncic, Ivo ;
Cikojevic, Drasko ;
Klancnik, Marisa ;
Racic, Goran ;
Spuzevic, Laura .
PAEDIATRIA CROATICA, 2010, 54 (01) :39-42
[47]   Foreign body aspiration in children [J].
Schmidt, H ;
Manegold, BC .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2000, 14 (07) :644-648
[48]   Diagnostic Performance of Multidetector Computed Tomography in Distinguishing Unilateral From Bilateral Abnormalities in Primary Hyperaldosteronism: Comparison of Multidetector Computed Tomography With Adrenal Vein Sampling [J].
Raman, Siva P. ;
Lessne, Mark ;
Kawamoto, Satomi ;
Chen, Yifei ;
Salvatori, Roberto ;
Prescott, Jason D. ;
Fishman, Elliot K. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (03) :414-418
[49]   Prevalence of Foreign Body Aspiration in Children in a Tertiary Care Hospital [J].
Dongol, Kripa ;
Neupane, Yogesh ;
Dutta, Heempali Das ;
Gyawali, Bigyan Raj ;
Kharel, Bijaya .
JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2021, 59 (234) :111-115
[50]   Foreign body aspiration in children: Field report of a German hospital [J].
Goektas, Oender ;
Snidero, Silvio ;
Jahnke, Volker ;
Passali, Desiderio ;
Gregori, Dario .
PEDIATRICS INTERNATIONAL, 2010, 52 (01) :100-103