Diagnostic performance of multidetector computed tomography for foreign body aspiration in children

被引:26
|
作者
Manach, Yves [1 ,2 ]
Pierrot, Sebastien [1 ]
Couloigner, Vincent [1 ,2 ]
Ayari-Khalfallah, Sonia [3 ]
Nicollas, Richard [4 ]
Venail, Frederic [5 ]
Pondaven, Soizick [6 ]
Baculard, Florence [7 ]
Tantcheu, Victor [8 ]
机构
[1] Hop Necker Enfants Malad, APHP, Paediat ENT Dept, F-75015 Paris, France
[2] Paris Descartes Univ, F-75006 Paris, France
[3] CHU Lyon, Paediat ENT Dept, FME Hosp, F-69500 Lyon Bron, France
[4] CHU Marseille, Paediat ENT Dept, Timone Hosp, F-13385 Marseille, France
[5] CHU Montpellier, Pediat ENT Dept, Guy de Chaulliac Hosp, F-34295 Montpellier, France
[6] CHU Tours, Paediat ENT Dept, Clocheville Hosp, F-37044 Tours, France
[7] Hop Robert Debre, APHP, Paediat ENT Dept, F-75935 Paris, France
[8] Hop Necker Enfants Malad, APHP, Dept Paediat Radiol, F-75015 Paris, France
关键词
Multidetector computed tomography; Foreign body; Aspiration; Respiratory; Children; Sensitivity and specificity; VIRTUAL BRONCHOSCOPY; PEDIATRIC-PATIENTS; CT; BODIES;
D O I
10.1016/j.ijporl.2013.02.016
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: To evaluate the sensitivity of multidetector computed tomography for confirming suspected foreign body aspiration into the airways in children. Method: We conducted a multicentre prospective study of 303 children evaluated using multidetector computed tomography with axial analysis complemented by multiplanar reconstruction when required. The images were read by a radiologist before endoscopy then reviewed later by a senior radiologist blinded to the endoscopy findings. Endoscopy was performed routinely. Results: Foreign bodies were found by endoscopy in 70 of the 303 children. The initial multidetector computed tomography reading was 94% sensitive and 95% specific. For the review, the images for 91 patients were excluded because of motion blurring or absence of larynx visualisation; in the remaining 212 patients, sensitivity was 98% and specificity 97%. Conclusion: Multidetector computed tomography as performed in our patients cannot replace endoscopy, which remains the reference standard. Nevertheless, multidetector. computed tomography is sufficiently sensitive to be of value when foreign body aspiration is not considered initially or when endoscopy is likely to prove challenging. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:808 / 812
页数:5
相关论文
共 50 条
  • [1] Role of computed tomography for diagnosis of foreign body aspiration in children
    Sodhi, Kushaljit Singh
    Saxena, Akshay Kumar
    Bhatia, Anmol
    PEDIATRICS INTERNATIONAL, 2021, 63 (05) : 612 - 613
  • [2] Thin-section axial multidetector computed tomography and multiplanar reformatted imaging of children with suspected foreign-body aspiration: Is virtual bronchoscopy overemphasized?
    Kocaoglu, M.
    Bulakbasi, N.
    Soylu, K.
    Demirbag, S.
    Tayfun, C.
    Somuncu, I.
    ACTA RADIOLOGICA, 2006, 47 (07) : 746 - 751
  • [3] Evaluation of computed tomography virtual bronchoscopy in paediatric tracheobronchial foreign body aspiration
    Bhat, K. V.
    Hegde, J. S.
    Nagalotimath, U. S.
    Patil, G. C.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2010, 124 (08) : 875 - 879
  • [4] Diagnostic Value of Chest Computed Tomography Scan for Identification of Foreign Body Aspiration in Children: A Systematic Review and Meta-analysis
    Goodarzy, Babak
    Rahmani, Erfan
    Farrokhi, Mehrdad
    Tavakoli, Reza
    Fard, Atousa Moghadam
    Ghaleh, Mohadese Ranjbaran
    Yazdi, Yeganeh Ghalichebaf
    Beni, Reza Amani
    Ghadirzadeh, Erfan
    Afrazeh, Fatemeh
    Khabir, Yalda Alipour
    Khabir, Sevda Alipour
    Bakhtiyari, Paria
    Atighi, Javaneh
    Mahjoubi, Mohammad
    Momeni, Zahra
    Jalayeri, Hediyeh
    Hosseini, Mohammad Hossein
    Hoorshad, Behnam
    Tavakoli, Mehdi
    Seifi, Sepideh
    Momeni, Hamidreza
    Mirbolook, Amirhossein
    Jobani, Alireza Esmaili
    Visroudi, Mozhdeh Mohammadi
    Najafi, Aboulfazl
    Hosseini, Zahrasadat
    Aboulhassanzadeh, Sobhan
    Ajami, Negar
    Ramezani, Sahel
    Manavi, Mahdokht Sadat
    Safdari, Sina
    Fallahian, Amirali
    Azimi, Habib
    Zahedpasha, Reza
    Ranjbar, Ehsan
    Kahrizi, Mohammad Saeed
    Lahijan, Lida Zare
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2025, 13 (01)
  • [5] Foreign Body Aspiration in Children-a Diagnostic Challenge
    Petrovic, Slobodanka
    Cegar, Svetlana
    Lovrenski, Jovan
    Barisic, Nenad
    Till, Viktor
    BALKAN MEDICAL JOURNAL, 2012, 29 (01) : 96 - 98
  • [6] Plastic foreign body in the pharynx can evade detection by computed tomography
    Sakamoto, Naoya
    Fujii, Shunsuke
    Masumoto, Kouji
    Matsuoka, Akira
    Toumine, Satoshi
    Hara, Tadahiko
    Shimada, Ken
    JOURNAL OF PEDIATRIC SURGERY CASE REPORTS, 2022, 84
  • [7] Diagnostic Evaluation of Foreign Body Aspiration in Children
    Erdem, Ali Onur
    Etensel, Barlas
    Yazici, Mesut
    Ozkisacik, Sezen Karaca
    JOURNAL OF PEDIATRIC RESEARCH, 2021, 8 (01) : 49 - 54
  • [8] Avoiding unnecessary bronchoscopy in children with suspected foreign body aspiration using computed tomography
    Gibbons, Alexander T.
    Berazaluce, Alejandra M. Casar
    Hanke, Rachel E.
    McNinch, Neil L.
    Person, Allison
    Mehlman, Tracey
    Rubin, Michael
    Ponsky, Todd A.
    JOURNAL OF PEDIATRIC SURGERY, 2020, 55 (01) : 176 - 181
  • [9] Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration
    Ibrahim Adaletli
    Sebuh Kurugoglu
    Sila Ulus
    Harun Ozer
    Mehmet Elicevik
    Fatih Kantarci
    Ismail Mihmanli
    Canan Akman
    Pediatric Radiology, 2007, 37 : 33 - 40
  • [10] Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration
    Adaletli, Ibrahim
    Kurugoglu, Sebuh
    Ulus, Sila
    Ozer, Harun
    Elicevik, Mehmet
    Kantarci, Fatih
    Mihmanli, Ismail
    Akman, Canan
    PEDIATRIC RADIOLOGY, 2007, 37 (01) : 33 - 40