Failure of Orthofix eight-Plate for the Treatment of Blount Disease

被引:104
作者
Schroerlucke, Samuel [1 ]
Bertrand, Styles [1 ]
Clapp, John [1 ]
Bundy, Justin [1 ]
Gregg, Frederick O. [1 ]
机构
[1] Med Coll Georgia, Dept Orthopaed, Augusta, GA 30912 USA
关键词
Blount; angular; deformity; genu varum; genu valgum; hemiepiphysiodesis; staples; tension band; osteotomy; implant failure; screw size; screw breakage; screw failure; PERCUTANEOUS EPIPHYSIODESIS; GROWTH; KNEE;
D O I
10.1097/BPO.0b013e3181919b54
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Hemiepiphysiodesis is a well-established treatment option for angular deformities of the knee. Recently, our institution began using the eight-Plate tension band device by Orthofix (McKinney, Tex) as an alternative to staples. However, several patients have returned with broken screws necessitating revision surgery. Methods: Charts and radiographs of all patients who were treated with the eight-Plate (Orthofix) at out, institution were reviewed. The diagnosis, age, amount of angular deformity, weight, and body mass index were analyzed with respect to eventual implant failure. Results: Implant failure occurred in 8 (26%) of 31 proximal tibia constructs. All 8 failures Occurred in patients with Blount disease and involved breakage of the tibial metaphyseal screw. The mean time to failure was 13.6 months. Eight hardware failures in 18 Blount disease extremities represent a failure rate of 44%. No implant failures occurred in the remaining diagnoses. Neither age nor degree of deformity correlated with implant failure. The failure group was significantly heavier than the nonfailure group, and the patients with Blount disease were found to be heavier than the other patients. However, no significant difference in weight was found within the Blount group regarding implant failure. In all patients whose plates did not fail, rate of correction was equal to or better than previously reported hemiepiphysiodesis studies. Conclusions: The eight-Plate (Orthofix) is a reasonable option for hemiepiphysiodesis but has all unacceptable failure rate in Blount disease (44%). There were no instances of failure in patients with other diagnoses. In Blount disease, stronger implants should be considered. Future implant. designs should include stronger screws to decrease implant failure complications.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 17 条
[1]   GROWTH AND PREDICTIONS OF GROWTH IN THE LOWER EXTREMITIES [J].
ANDERSON, M ;
GREEN, WT ;
MESSNER, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1963, 45 (01) :1-14
[2]  
AYKUT U, 2001, J PEDIATR ORTHOPED, V25, P336
[3]   CONTROL OF BONE GROWTH BY EPIPHYSEAL STAPLING - A PRELIMINARY REPORT [J].
BLOUNT, WP ;
CLARKE, GR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1949, 31-A (03) :464-478
[4]  
BOWEN JR, 1985, CLIN ORTHOP RELAT R, P184
[5]   PERCUTANEOUS EPIPHYSIODESIS - EXPERIMENTAL-STUDY AND PRELIMINARY CLINICAL-RESULTS [J].
CANALE, ST ;
RUSSELL, TA ;
HOLCOMB, RL .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1986, 6 (02) :150-156
[6]  
Carter JR, 1988, BEHAV GROWTH PLATE, P285
[7]   Hemiepiphysiodesis for the correction of angular deformity about the knee [J].
Castaneda, Pablo ;
Urquhart, Bradford ;
Sullivan, Elroy ;
Haynes, Richard J. .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2008, 28 (02) :188-191
[8]  
Collinge CA, 2000, CLIN ORTHOP RELAT R, P277
[9]   BLOUNT DISEASE (TIBIA VARA) - ANOTHER SKELETAL DISORDER ASSOCIATED WITH CHILDHOOD OBESITY [J].
DIETZ, WH ;
GROSS, WL ;
KIRKPATRICK, JA .
JOURNAL OF PEDIATRICS, 1982, 101 (05) :735-737
[10]   Quantitative three-dimensional analysis of chondrocytic kinetic responses to short-term stapling of the rat proximal tibial growth plate [J].
Farnum, CE ;
Nixon, A ;
Belanger, L ;
Wilsman, NJ .
CELLS TISSUES ORGANS, 2000, 167 (04) :247-258