Experimental investigation on the heat transfer performance of evacuated tube solar collector using CuO nanofluid and water

被引:19
作者
Kang, Woobin [1 ]
Shin, Yunchan [1 ]
Cho, Honghyun [2 ]
机构
[1] Chosun Univ, Grad Sch, 303 Pilmundaero, Gwangju 61452, South Korea
[2] Chosun Univ, Dept Mech Engn, 303 Pilmundaero, Gwangju 61452, South Korea
基金
新加坡国家研究基金会;
关键词
Evacuated tube solar collector; Nanofluid; Thermal efficiency; CuO (copper oxide); Heat loss parameter; THERMAL-CONDUCTIVITY; ETHYLENE-GLYCOL; EFFICIENCY; ENERGY; AL2O3;
D O I
10.1007/s12206-019-0249-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The efficiency of an evacuated tube solar collector was experimentally measured and analyzed according to the size of CuO nanoparticle and the concentration of the CuO nanofluid. In addition, the efficiency of the evacuated tube solar collector using CuO nanofluid as a working fluid was compared with that when water was used. As a result, the efficiency of the evacuated tube solar collector improved as the concentration of the CuO nanofluid increased at low concentration. Further, the efficiency of the evacuated tube solar collector was higher at a mass flux rate of 598 kg/sm(2) than at 420 kg/sm(2). The highest efficiency of the solar collector with 40 nm-CuO nanofluid was 69.1 %, an improvement of 2.0 % compared to 80 nm-CuO nanofluid. The most optimal concentration of the 40 nm-CuO nanofluid was 0.5 vol% and an improvement of thermal efficiency was 7.2 % compared to water. In addition, at this concentration, the efficiency improved by 4.4 %, 2.3 % and 0.3 % compared to that at concentrations of 0.1 vol%, 0.3 vol% and 0.7 vol%, respectively. The use of CuO nanofluid in the evacuated tube solar collector can improve the efficiency and can maintain the high efficiency for wide operating conditions compared to water.
引用
收藏
页码:1477 / 1485
页数:9
相关论文
共 28 条
[1]   Modeling, Simulation and Optimization of a Solar Absorption Air Conditioning System for an Office Block in Zaria, Nigeria [J].
Ahmadu, T. O. ;
Folayan, C. O. ;
Anafi, F. O. .
INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (02)
[2]   Thermal conductivity of Al2O3 + TiO2/water nanofluid: Model development and experimental validation [J].
Charab, Alireza Azadi ;
Movahedirad, Salman ;
Norouzbeigi, Reza .
APPLIED THERMAL ENGINEERING, 2017, 119 :42-51
[3]   Thermal conductivity and viscosity of Al2O3 nanofluids for different based ratio of water and ethylene glycol mixture [J].
Chiam, H. W. ;
Azmi, W. H. ;
Usri, N. A. ;
Mamat, Rizalman ;
Adam, N. M. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 81 :420-429
[4]   Effects of different working fluid use on the energy and exergy performance for evacuated tube solar collector with thermosyphon heat pipe [J].
Ersoz, Mustafa Ali .
RENEWABLE ENERGY, 2016, 96 :244-256
[5]   Energy, economic and environmental analysis of metal oxides nanofluid for flat-plate solar collector [J].
Faizal, M. ;
Saidur, R. ;
Mekhilef, S. ;
Alim, M. A. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 76 :162-168
[6]   Performance of copper oxide/distilled water nanofluid in evacuated tube solar collector (ETSC) water heater with internal coil under thermosyphon system circulations [J].
Ghaderian, Javad ;
Sidik, Nor Azwadi Che ;
Kasaeian, Alibakhsh ;
Ghaderian, Sepideh ;
Okhovat, Amir ;
Pakzadeh, Amirabbas ;
Samion, Syahrullail ;
Yahya, Wira Jazair .
APPLIED THERMAL ENGINEERING, 2017, 121 :520-536
[7]   An experimental investigation on the effect of Al2O3/distilled water nanofluid on the energy efficiency of evacuated tube solar collector [J].
Ghaderian, Javad ;
Sidik, Nor Azwadi Che .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 :972-987
[8]   Experimental investigation on the efficiency of flat-plate solar collectors with nanofluids [J].
He, Qinbo ;
Zeng, Shequan ;
Wang, Shuangfeng .
APPLIED THERMAL ENGINEERING, 2015, 88 :165-171
[9]  
Hussain HA., 2015, Solar Energy, V4, P19
[10]  
Khaldi S, 2017, INT J AIR-COND REFRI, V25, DOI 10.1142/S2010132517500225