Quantification of apolipoprotein D by an immunoassay with time-resolved fluorescence spectroscopy

被引:11
|
作者
Knipping, G [1 ]
GoggFassolter, G [1 ]
Frohnwieser, B [1 ]
Krempler, F [1 ]
Kostner, GM [1 ]
Malle, E [1 ]
机构
[1] HOSP HALLEIN,DEPT INTERNAL MED,A-5400 HALLEIN,AUSTRIA
关键词
dissociation-enhanced lanthanide fluorescence immunoassay; fluoroimmunoassay; gross cystic disease fluid protein-24; lipocalin; breast cancer cell; GROSS CYSTIC-DISEASE; BREAST-CANCER CELLS; D GENE; PROTEIN; EXPRESSION; FLUID; SERUM; CHOLESTEROL; COMPONENT; SECRETION;
D O I
10.1016/S0022-1759(96)00240-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Apolipoprotein D (apoD). also known as gross cystic disease fluid protein-24 (GCDFP-24). is a minor protein moiety of high-density lipoproteins in human plasma. ApoD is expressed in a subset of breast carcinomas and has been proposed as a tumor marker and prognostic indicator for breast cancer progression. Here we describe a new sensitive time-resolved fluorimetric immunoassay for quantification of human apoD in biological specimens using affinity-purified polyclonal anti-human apoD rabbit antibodies and Eu3+ as a specific probe, Both purified apoD and normal human pool-serum served as reliable primary and secondary standards in the direct sandwich dissociation-enhanced lanthanide fluorescence immunoassay (DELFIA). Plasma apoD concentrations measured by the DELFIA were 99.6 +/- 32 mu g/ml. The detection limit of the DELFIA procedure was 0.5 ng/ml after sample dilution of 1/8000. The intra-assay coefficient of variation averaged 3.5%, whereas the inter-assay coefficient of variation averaged 6.9%. The concentration of apoD in breast cyst fluids ranged from 6.82 to 28.37 mg/ml. Based on the low detection limit and the high specificity of the DELFIA procedure, we have applied this technique for the measurement of apoD in breast cancer cell supernatants. In estrogen-receptor positive cells, i.e., T-47D and ZR-75-1 cells, 42.6 +/- 1.4 and 2.7 +/- 0.2 ng apoD/ml supernatant after 4 days in culture without induction of apoD synthesis were measured. A comparison of the direct sandwich DELFIA procedure with an electroimmunoassay commonly used to assay apoD revealed correlation coefficients of 0.986 (serum) and 0.975 (cyst fluids). The present findings indicate that the direct sandwich DELFIA is appropriate for apoD quantification in plasma and breast cyst fluids, Furthermore, the technique should permit studies on the induction of apoD synthesis in the low picomolar range in different carcinoma cells to gain insight into the expression of this atypical apolipoprotein.
引用
收藏
页码:85 / 95
页数:11
相关论文
共 50 条
  • [21] TIME-RESOLVED FLUORESCENCE SPECTROSCOPY OF PROTEINS AND POLYPEPTIDES
    ROSS, JBA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 30 - ANYL
  • [22] TIME-RESOLVED FLUORESCENCE SPECTROSCOPY OF SPINACH CHLOROPLAST
    YU, W
    PELLEGRINO, F
    ALFANO, RR
    BIOCHIMICA ET BIOPHYSICA ACTA, 1977, 460 (01) : 171 - 181
  • [23] TIME-RESOLVED FLUORESCENCE EXCITATION SPECTROSCOPY OF STYRENES
    GHIGGINO, KP
    HARA, K
    SALISBURY, K
    PHILLIPS, D
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS II, 1978, 74 : 607 - 610
  • [24] Diagnosis of meningioma by time-resolved fluorescence spectroscopy
    Butte, PV
    Pikul, BK
    Hever, A
    Yong, WH
    Black, KL
    Marcu, L
    JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (06)
  • [25] Development of a multipurpose time-resolved fluorescence immunoassay for rat insulin
    van Genderen, Farah T.
    Gorus, Frans K.
    Vermeulen, Ilse
    Vekens, Evilien M. F.
    De Pauw, Pieter E. M.
    Pipeleers, Daniel G.
    Van Schravendijk, Chris
    ANALYTICAL BIOCHEMISTRY, 2010, 404 (01) : 8 - 13
  • [26] Total error profiling of a proinsulin time-resolved fluorescence immunoassay
    De Pauw, P. E.
    Mackin, R. B.
    Goubert, R.
    Van Schravendijk, C.
    Gorus, F. K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2403 - 2406
  • [27] ENZYMATICALLY AMPLIFIED TIME-RESOLVED FLUORESCENCE IMMUNOASSAY WITH TERBIUM CHELATES
    CHRISTOPOULOS, TK
    DIAMANDIS, EP
    ANALYTICAL CHEMISTRY, 1992, 64 (04) : 342 - 346
  • [28] Spectra-resolved technique of a sensitive time-resolved fluorescence immunoassay instrument
    Guo, ZY
    Tian, Z
    Jia, YL
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 222 - 226
  • [29] Rapid Quantification of SARS-CoV-2 Neutralising Antibodies Using Time-Resolved Fluorescence Immunoassay
    McLean, Gary R. R.
    Zhang, Yueke
    Ndoyi, Rene
    Martin, Adam
    Winer, Julian
    VACCINES, 2022, 10 (12)
  • [30] Introduction to Time-Resolved Spectroscopy: Nanosecond Transient Absorption and Time-Resolved Fluorescence of Eosin B
    Farr, Erik P.
    Quintana, Jason C.
    Reynoso, Vanessa
    Ruberry, Josiah D.
    Shin, Wook R.
    Swartz, Kevin R.
    JOURNAL OF CHEMICAL EDUCATION, 2018, 95 (05) : 864 - 871