Electrochemical Immunosensor for Early Detection of β-Amyloid Alzheimer's Disease Biomarker Based on Aligned Carbon Nanotubes Gold Nanocomposites

被引:12
作者
Ranjan, Pushpesh [1 ,2 ]
Khan, Raju [1 ,2 ]
机构
[1] Adv Mat & Proc Res Inst AMPRI, CSIR, Hoshangabad Rd, Bhopal 462026, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 11期
关键词
Alzheimer's disease; beta-amyloid peptide; electrochemical immunosensor; gold nanoparticles; aligned carbon nanotube; chitosan; BIOSENSORS;
D O I
10.3390/bios12111059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Beta-amyloid (beta A) peptides accompanying the physiological change in brain induce Alzheimer's disease. In this work, a highly sensitive electrochemical (EC) immunosensor platform has been developed for the quantitative detection of beta A peptides, using the gold nanoparticle functionalized chitosan-aligned carbon nanotube (CS-aCNT-Au) nanocomposites on glassy carbon electrodes (GCE). The immunosensor has been fabricated by immobilization of the anti-beta A antibody upon CS-aCNT-Au/GCE. In the CS-aCNT nanocomposite, CS has high biocompatibility. Hydroxy and amine functionalities favor the antibody immobilization and prevent the leaching of nanocomposites of the modified electrode due to the adhesive environment. Moreover, aCNT offers high conductivity, stability, and a large surface area (the calculated effective surface area of the CS-aCNT/GCE is 8.594 x 10(-2) cm(2)). However, the incorporation of AuNPs further enhances the conductivity of the CS-aCNT-Au nanocomposite based on differential pulse voltammetry (DPV) results, and also improves the effective surface area (9.735 x 10(-2) cm(2)). The surface morphology and electrochemical studies of the nanocomposite, as well as its modifications by the anti-beta A antibody and BSA, were carried out through field emission scanning electron microscope (FESEM), cyclic voltammetry (CV), and DPV. The quantitative immunosensing of the beta A in phosphate-buffered saline (PBS) solution is accomplished via DPV, which reveals that the immunosensor has a high sensitivity of 157.60 mu A pg(-1) mL cm(-2) and a broad detection range of 10.0 pg mL(-1) -100.0 mu g mL(-1), with a limit of detection (LOD) of 0.87 pg mL(-1). Subsequently, we detected the spiked beta A in diluted serum with a linear detection range of 10.0 pg mL(-1) -1.0 ng mL(-1) and LOD of 0.95 pg mL(-1) . Moreover, a selectivity study exhibited a high affinity of immunosensors towards beta A. Thus, we propose that this highly efficient immunosensor can potentially be applied for the point-of-care (POC) sensing of beta A in clinical samples.
引用
收藏
页数:12
相关论文
共 32 条
[1]   Graphene based electrochemical immunosensor for the ultra-sensitive label free detection of Alzheimer's beta amyloid peptides Aβ(1-42) [J].
Abbasi, Hina Y. ;
Tehrani, Zari ;
Devadoss, Anitha ;
Ali, Muhammad Munem ;
Moradi-Bachiller, Soraya ;
Albani, Diego ;
Guy, Owen J. .
NANOSCALE ADVANCES, 2021, 3 (08) :2295-2304
[2]   Antimicrobial and biocompatible fluorescent hydroxyapatite-chitosan nanocomposite films for biomedical applications [J].
Banerjee, Somtirtha ;
Bagchi, Biswajoy ;
Bhandary, Suman ;
Kool, Arpan ;
Hoque, Nur Amin ;
Biswas, Prosenjit ;
Pal, Kunal ;
Thakur, Pradip ;
Das, Kaustuv ;
Karmakar, Parimal ;
Das, Sukhen .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2018, 171 :300-307
[3]   Recent Advances in Voltammetry [J].
Batchelor-McAuley, Christopher ;
Kaetelhoen, Enno ;
Barnes, Edward O. ;
Compton, Richard G. ;
Laborda, Eduardo ;
Molina, Angela .
CHEMISTRYOPEN, 2015, 4 (03) :224-260
[4]   Recent advances in carbon nanotube-based biosensors for biomolecular detection [J].
Dai, Benhui ;
Zhou, Ruiyun ;
Ping, Jianfeng ;
Ying, Yibin ;
Xie, Lijuan .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 154
[5]   Au/NiFe2O4 nanoparticle-decorated graphene oxide nanosheets for electrochemical immunosensing of amyloid beta peptide [J].
Devi, Rashmita ;
Gogoi, Satyabrat ;
Dutta, Hemant Sankar ;
Bordoloi, Manabjyoti ;
Sanghi, Sunil K. ;
Khan, Raju .
NANOSCALE ADVANCES, 2020, 2 (01) :239-248
[6]   Electrochemical detection of monosodium glutamate in foodstuffs based on Au@MoS2/chitosan modified glassy carbon electrode [J].
Devi, Rashmita ;
Gogoi, Satyabrat ;
Barua, Shaswat ;
Dutta, Hemant Sankar ;
Bordoloi, Manobjyoti ;
Khan, Raju .
FOOD CHEMISTRY, 2019, 276 :350-357
[7]   A Practical Beginner's Guide to Cyclic Voltammetry [J].
Elgrishi, Noemie ;
Rountree, Kelley J. ;
McCarthy, Brian D. ;
Rountree, Eric S. ;
Eisenhart, Thomas T. ;
Dempsey, Jillian L. .
JOURNAL OF CHEMICAL EDUCATION, 2018, 95 (02) :197-206
[8]   Carbon Nanotube (CNT)-Based Biosensors [J].
Ferrier, David C. ;
Honeychurch, Kevin C. .
BIOSENSORS-BASEL, 2021, 11 (12)
[9]   2022 Alzheimer's disease facts and figures [J].
Gaugler, Joseph ;
James, Bryan ;
Johnson, Tricia ;
Reimer, Jessica ;
Solis, Michele ;
Weuve, Jennifer ;
Buckley, Rachel F. ;
Hohman, Timothy J. .
ALZHEIMERS & DEMENTIA, 2022, 18 (04) :700-789
[10]   Electrochemical approaches for the detection of amyloid-β, tau, and α-synuclein [J].
Hassan, Qusai ;
Kerman, Kagan .
CURRENT OPINION IN ELECTROCHEMISTRY, 2019, 14 :89-95