Correction of concomitant gradient artifacts in experimental microtesla MRI

被引:29
作者
Myers, WR [1 ]
Mössle, M
Clarke, J
机构
[1] Univ Calif Berkeley, Dept Phys, Berkeley, CA 94720 USA
[2] Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
关键词
magnetic resonance imaging; low field; concomitant gradient; phase correction; field cycling;
D O I
10.1016/j.jmr.2005.08.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Magnetic resonance imaging (MRI) suffers from artifacts caused by concomitant gradients when the product of the magnetic field gradient and the dimension of the sample becomes comparable to the static magnetic field. To investigate and correct for these artifacts at very low magnetic fields, we have acquired MR images of a 165-mm phantom in a 66-mu T field using gradients up to 350 mu T/m. We prepolarize the protons in a field of about 100 mT, apply a spin-echo pulse sequence, and detect the precessing spins using a superconducting gradiometer coupled to a superconducting quantum interference device (SQUID). Distortion and blurring are readily apparent at the edges of the images; by comparing the experimental images to computer simulations, we show that concomitant gradients cause these artifacts. We develop a non-perturbative, post-acquisition phase correction algorithm that eliminates the effects of concomitant gradients in both the simulated and the experimental images. This algorithm assumes that the switching time of the phase-encoding gradient is long compared to the spin precession period. In a second technique, we demonstrate that raising the precession field during phase encoding can also eliminate blurring caused by concomitant phase-encoding gradients; this technique enables one to correct concomitant gradient artifacts even when the detector has a restricted bandwidth that sets an upper limit on the precession frequency. In particular, the combination of phase correction and precession field cycling should allow one to add MRI capabilities to existing 300-channel SQUID systems used to detect neuronal currents in the brain because frequency encoding could be performed within the 1-2 kHz bandwidth of the readout system. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:274 / 284
页数:11
相关论文
共 31 条
[1]   Low field magnetic resonance images of polarized noble gases obtained with a dc superconducting quantum interference device [J].
Augustine, MP ;
Wong-Foy, A ;
Yarger, JL ;
Tomaselli, M ;
Pines, A ;
TonThat, DM ;
Clarke, J .
APPLIED PHYSICS LETTERS, 1998, 72 (15) :1908-1910
[2]   Concomitant gradient terms in phase contrast MR: Analysis and correction [J].
Bernstein, MA ;
Zhou, XHJ ;
Polzin, JA ;
King, KF ;
Ganin, A ;
Pelc, NJ ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) :300-308
[3]   MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT) [J].
Bidinosti, CP ;
Choukeife, J ;
Tastevin, G ;
Vignaud, A ;
Nacher, PJ .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (06) :255-258
[4]   In vivo NMR of hyperpolarized 3He in the human lung at very low magnetic fields [J].
Bidinosti, CP ;
Choukeife, J ;
Nacher, PJ ;
Tastevin, G .
JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (01) :122-132
[5]  
CLASSENVUJCIC T, 1995, P SOC MAGN RESON, V3, P56
[6]  
CLASSENVUJCIC T, 1997, P INT SOC MAGN RESON, V5, P110
[7]   Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging [J].
Du, YPP ;
Zhou, XHJ ;
Bernstein, MA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :509-515
[8]   NUCLEAR-RELAXATION OF HUMAN BRAIN GRAY AND WHITE MATTER - ANALYSIS OF FIELD-DEPENDENCE AND IMPLICATIONS FOR MRI [J].
FISCHER, HW ;
RINCK, PA ;
VANHAVERBEKE, Y ;
MULLER, RN .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :317-334
[9]  
Haacke EM, 1999, MAGNETIC RESONANCE I, P296
[10]  
King KF, 1999, MAGNET RESON MED, V41, P103, DOI 10.1002/(SICI)1522-2594(199901)41:1<103::AID-MRM15>3.0.CO