Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach

被引:158
|
作者
Teng, XF [1 ]
Zhang, YT [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Joint Res Ctr Biomed Engn, Hong Kong, Hong Kong, Peoples R China
来源
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH | 2003年 / 25卷
关键词
blood pressure; photoplethysmography; noninvasive measurement;
D O I
10.1109/IEMBS.2003.1280811
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arterial blood pressure is one of the most important physiological parameters for the noninvasive diagnosis and monitoring of cardiovascular diseases. This study examines the relationships between arterial blood pressure and certain features of the photoplethysmographic (PPG) signals obtained from 15 young healthy subjects. Width of 1/2 pulse amplitude, width of 2/3 pulse amplitude, systolic upstroke time and diastolic time of the pulse were selected as features of the PPG signals. The experiment involved three sessions: rest, step-climbing exercise, and recovery from exercise. It was found that the diastolic time has higher correlation with systolic blood pressure (SBP) and diastolic blood pressure (DBP) than other features. The mean differences between the estimated and the measured blood pressure using a standard device are 0.21 mmHg for SBP and 0.02 mmHg for DBP. The corresponding standard deviations are 7.32 mmHg for SBP and 4.39 mmHg for DBP. The preliminary results indicate that it is possible to use the photoplethysmography only for cuffless and continuous estimation of arterial blood pressure.
引用
收藏
页码:3153 / 3156
页数:4
相关论文
共 50 条
  • [41] Comparable parameter related to arterial stiffness in blood pressure estimation method
    Kim, Jung Soo
    Kim, Ko Keun
    Baek, Hyun Jae
    Park, Kwang Suk
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 150 - +
  • [42] Continuous Cuff-Less Blood Pressure Estimation Based on Combined Information Using Deep Learning Approach
    Wu, Dan
    Xu, Lin
    Zhang, Ruiqin
    Zhang, Heye
    Ren, Lijie
    Zhang, Yuan-Ting
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (06) : 1290 - 1299
  • [43] Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study
    Tusman, Gerardo
    Acosta, Cecilia M.
    Pulletz, Sven
    Boehm, Stephan H.
    Scandurra, Adriana
    Martinez Arca, Jorge
    Madorno, Matias
    Suarez Sipmann, Fernando
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (05) : 815 - 824
  • [44] Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time
    Xiang, Haiyan
    Liu, Yanyong
    Li, Yinhua
    Qin, Yufei
    Yu, Mengsun
    BLOOD PRESSURE MONITORING, 2012, 17 (01) : 35 - 41
  • [45] Noninvasive continuous arterial pressure measurements in the assessment of acute, severe central hypovolemia
    Simon, J.
    Farkas, T.
    Gingl, Z.
    Csillik, A.
    Korsos, A.
    Rudas, L.
    Zoellei, E.
    ACTA PHYSIOLOGICA HUNGARICA, 2015, 102 (01) : 43 - 50
  • [46] Arterial stiffness estimation based photoplethysmographic pulse wave analysis
    Huotari, Matti
    Maatta, Kari
    Kostamovaara, Juha
    LASER APPLICATIONS IN LIFE SCIENCES, 2010, 7376
  • [47] Noninvasive assessment of arterial pressure
    Chemla, Denis
    Teboul, Jean-Louis
    Richard, Christian
    CURRENT OPINION IN CRITICAL CARE, 2008, 14 (03) : 317 - 321
  • [48] A ring-type device for the noninvasive measurement of arterial blood pressure
    Zheng, DC
    Zhang, YT
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3184 - 3187
  • [49] Advancing Continuous Blood Pressure Estimation with Transformer on Photoplethysmography in Operation Room
    Lee, Nayoung
    Kim, Sang-Hyun
    Lee, Misoon
    Woo, Jiyoung
    IEEE ACCESS, 2024, 12 : 90486 - 90500
  • [50] A novel method for the noninvasive estimation of cardiac output with brachial oscillometric blood pressure measurements through an assessment of arterial compliance
    Alvarez-Montoya, Diego
    Madrid-Munoz, Camilo
    Escobar-Robledo, Luis
    Gallo-Villegas, Jaime
    Aristizabal-Ocampo, Dagnovar
    BLOOD PRESSURE MONITORING, 2021, 26 (06) : 426 - 434