Experimental performance of a thermoelectric ceiling cooling panel

被引:23
作者
Lertsatitthanakorn, C. [1 ]
Srisuwan, W. [1 ]
Atthajariyakul, S. [1 ]
机构
[1] Mahasarakham Univ, Fac Engn, Khantarawichai 44150, Mahasarakham, Thailand
关键词
cooling capacity; COP; indoor temperature; thermal comfort;
D O I
10.1002/er.1391
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An experiment has been performed to investigate the cooling performance of a thermoelectric ceiling cooling panel (TE-CCP). The TE-CCP was composed of 36 TE modules. The cold side of the TE modules was fixed to an aluminum ceiling panel to cool a test chamber of 4.5 m(3) volume, while a copper heat exchanger with circulating cooling water at the hot side of the TE modules was used for heat release. Tests were conducted using various system parameters. It was found that the cooling performance of the system depended on the electrical supply, cooling water temperature and flow rate through the heat exchanger. A suitable condition occurred at 1.5 A of current flow with a corresponding cooling capacity of 289.4 W which gives the coefficient of performance (COP) of 0.75 with an average indoor temperature of 27 degrees C. Using thermal comfort test data in literature for small air movements under radiant cooling ceilings, results from the experiments show that thermal comfort could be obtained with the TE-CCP system. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:950 / 957
页数:8
相关论文
共 20 条
[1]  
Bansal PK, 2000, INT J ENERG RES, V24, P93, DOI 10.1002/(SICI)1099-114X(200002)24:2<93::AID-ER563>3.0.CO
[2]  
2-6
[3]   Comparison of the optimal performance of single- and two-stage thermoelectric refrigeration systems [J].
Chen, JC ;
Zhou, YH ;
Wang, HJ ;
Wang, JT .
APPLIED ENERGY, 2002, 73 (3-4) :285-298
[4]   Experimental investigation on a thermoelectric refrigerator driven by solar cells [J].
Dai, YJ ;
Wang, RZ ;
Ni, L .
RENEWABLE ENERGY, 2003, 28 (06) :949-959
[5]   COMFORT LIMITS FOR ASYMMETRIC THERMAL-RADIATION [J].
FANGER, PO ;
IPSEN, BM ;
LANGKILDE, G ;
OLESEN, BW ;
CHRISTENSEN, NK ;
TANABE, S .
ENERGY AND BUILDINGS, 1985, 8 (03) :225-236
[6]   A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification [J].
Hao, Xiaoli ;
Zhang, Guoqiang ;
Chen, Youming ;
Zou, Shenghua ;
Moschandreas, Demetrios. J. .
BUILDING AND ENVIRONMENT, 2007, 42 (09) :3298-3308
[7]  
Holman J.P., 1994, Experimental Methods for
[8]  
HOUGHTON J, 1997, GLOBAL WARMING
[9]   A design method of thermoelectric cooler [J].
Huang, BJ ;
Chin, CJ ;
Duang, CL .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03) :208-218
[10]   Thermal comfort and energy consumption of the radiant ceiling panel system. Comparison with the conventional all-air system [J].
Imanari, T ;
Omori, T ;
Bogaki, K .
ENERGY AND BUILDINGS, 1999, 30 (02) :167-175