Error detection and classification in patient-specific IMRT QA with dual neural networks

被引:27
|
作者
Potter, Nicholas J. [1 ]
Mund, Karl [1 ]
Andreozzi, Jacqueline M. [1 ]
Li, Jonathan G. [1 ]
Liu, Chihray [1 ]
Yan, Guanghua [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32611 USA
关键词
classification; error detection; IMRT QA; machine learning; QUALITY-ASSURANCE; QUANTITATIVE-EVALUATION; RADIOMIC ANALYSIS; DOSE CALCULATION; DOSIMETRY; DELIVERY;
D O I
10.1002/mp.14416
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Despite being the standard metric in patient-specific quality assurance (QA) for intensity-modulated radiotherapy (IMRT), gamma analysis has two shortcomings: (a) it lacks sensitivity to small but clinically relevant errors (b) it does not provide efficient means to classify the error sources. The purpose of this work is to propose a dual neural network method to achieve simultaneous error detection and classification in patient-specific IMRT QA. Methods For a pair of dose distributions, we extracted the dose difference histogram (DDH) for the low dose gradient region and two signed distance-to-agreement (sDTA) maps (one in x direction and one in y direction) for the high dose gradient region. An artificial neural network (ANN) and a convolutional neural network (CNN) were designed to analyze the DDH and the two sDTA maps, respectively. The ANN was trained to detect and classify six classes of dosimetric errors: incorrect multileaf collimator (MLC) transmission (+/- 1%) and four types of monitor unit (MU) scaling errors (+/- 1% and +/- 2%). The CNN was trained to detect and classify seven classes of spatial errors: incorrect effective source size, 1 mm MLC leaf bank overtravel or undertravel, 2 mm single MLC leaf overtravel or undertravel, and device misalignment errors (1 mm in x- or y direction). An in-house planar dose calculation software was used to simulate measurements with errors and noise introduced. Both networks were trained and validated with 13 IMRT plans (totaling 88 fields). A fivefold cross-validation technique was used to evaluate their accuracy. Results Distinct features were found in the DDH and the sDTA maps. The ANN perfectly identified all four types of MU scaling errors and the specific accuracies for the classes of no error, MLC transmission increase, MLC transmission decrease were 98.9%, 96.6%, and 94.3%, respectively. For the CNN, the largest confusion occurred between the 1-mm-MLC bank overtravel class and the 1-mm-device alignment error in x-direction class, which brought the specific accuracies down to 90.9% and 92.0%, respectively. The specific accuracy for the 2-mm-single MLC leaf undertravel class was 93.2% as it misclassified 5.7% of the class as being error free (false negative). Otherwise, the specific accuracy was above 95%. The overall accuracies across the fivefold were 98.3 +/- 0.7% and 95.6% +/- 1.5% for the ANN and the CNN, respectively. Conclusions Both the DDH and the sDTA maps are suitable features for error classification in IMRT QA. The proposed dual neural network method achieved simultaneous error detection and classification with excellent accuracy. It could be used in complement with the gamma analysis to potentially shift the IMRT QA paradigm from passive pass/fail analysis to active error detection and root cause identification.
引用
收藏
页码:4711 / 4720
页数:10
相关论文
共 50 条
  • [41] Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA
    Hillman, Yair
    Kim, Josh
    Chetty, Indrin
    Wen, Ning
    MEDICAL PHYSICS, 2018, 45 (04) : 1351 - 1359
  • [42] SRS/SBRT patient-specific QA device comparison: Electronic QA devices vs film dosimetry
    Shacham, Tamir
    Epstein, Dan
    Levin, Daphne
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3317 - S3318
  • [43] Patient-specific seizure onset detection
    Shoeb, A
    Edwards, H
    Connolly, J
    Bourgeois, B
    Treves, T
    Guttag, J
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 419 - 422
  • [44] Patient-specific point dose measurement for IMRT monitor unit verification
    Dong, L
    Antolak, J
    Salehpour, M
    Forster, K
    O'Neill, L
    Kendall, R
    Rosen, I
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (03): : 867 - 877
  • [45] The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT
    Kim, Jung-In
    Park, So-Yeon
    Kim, Hak Jae
    Kim, Jin Ho
    Ye, Sung-Joon
    Park, Jong Min
    RADIATION ONCOLOGY, 2014, 9
  • [46] Robotic radiosurgery system patient-specific QA for extracranial treatments using the planar ion chamber array and the cylindrical diode array
    Lin, Mu-Han
    Veltchev, Iavor
    Koren, Sion
    Ma, Charlie
    Li, Jinsgeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04): : 290 - 305
  • [47] An investigation of the IQM signal variation and error detection sensitivity for patient specific pre-treatment QA
    Alharthi, Thahabah
    George, Armia
    Arumugam, Sankar
    Holloway, Lois
    Thwaites, David
    Vial, Phil
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 6 - 18
  • [48] Feasibility Study of the Fluence-to-Dose Network (FDNet) for Patient-Specific IMRT Quality Assurance
    Cheon, Wonjoong
    Kim, Sung Jin
    Hwang, Ui-Jung
    Min, Byung Jun
    Han, Youngyih
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 75 (09) : 724 - 734
  • [49] Predicting VMAT patient-specific QA results using a support vector classifier trained on treatment plan characteristics and linac QC metrics
    Granville, Dal A.
    Sutherland, Justin G.
    Belec, Jason G.
    La Russa, Daniel J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09):
  • [50] Classification error of multilayer perceptron neural networks
    Feng, Lihua
    Hong, Weihu
    NEURAL COMPUTING & APPLICATIONS, 2009, 18 (04): : 377 - 380