共 5 条
In-situ temperature calibration procedure for temperature and strain fibre Bragg grating sensors for monitoring pre-stressing strands
被引:1
作者:
Mckeeman, I.
[1
]
Fusiek, G.
[1
]
Perry, M.
[1
]
Niewczas, P.
[1
]
Johnston, M.
[2
]
机构:
[1] Univ Strathclyde, Dept Engn, Glasgow, Lanark, Scotland
[2] Nucl Generat, EDF Energy, Civil Design Grp, E Kilbride, Lanark, Scotland
来源:
24TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS
|
2015年
/
9634卷
关键词:
prestress monitoring;
fibre Bragg gratings;
structural health monitoring;
temperature calibration;
OPTIC SENSORS;
D O I:
10.1117/12.2193193
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
In this work, we demonstrate active and passive methods for in-situ temperature calibration of fibre Bragg grating strain and temperature sensors. The method is suitable for characterizing sensors which are already attached to the steel reinforcements of civil structures. The proposed method, which involves the use of active induction heating or passive room temperature fluctuations, can be implemented using portable equipment, is time efficient, and can be used to calibrate attached sensors on-site, rather than in lab conditions. Preliminary results of the induction heating calibration show good agreement with pre-calibrated temperature sensors. In-situ calibration of fibre strain sensors, attached to a prestressing strand is also successfully carried out.
引用
收藏
页数:4
相关论文