Intra-individual comparison of conventional and simultaneous multislice-accelerated diffusion-weighted imaging in upper abdominal solid organs: value of ADC normalization using the spleen as a reference organ

被引:9
作者
Jang, Weon [1 ]
Song, Ji Soo [1 ,2 ,3 ]
Kwak, Hyo Sung [1 ,2 ,3 ]
Hwang, Seung Bae [1 ,2 ,3 ]
Paek, Mun Young [4 ]
机构
[1] Chonbuk Natl Univ, Dept Radiol, Med Sch & Hosp, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
[2] Chonbuk Natl Univ, Res Inst Clin Med, Jeonju, South Korea
[3] Chonbuk Natl Univ Hosp, Biomed Res Inst, Jeonju, South Korea
[4] Siemens Healthineers Ltd, Seoul, South Korea
关键词
Diffusion magnetic resonance imaging; Magnetic resonance imaging; Spleen; Abdomen; COEFFICIENT MEASUREMENTS; LIVER; MRI; TESLA; REPRODUCIBILITY; CIRRHOSIS;
D O I
10.1007/s00261-019-01924-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare the apparent diffusion coefficient (ADC) value of conventional diffusion-weighted imaging (cDWI) to simultaneous multislice-accelerated DWI (sDWI) and to evaluate the possibility of ADC normalization using the spleen as a reference organ.MethodsWe retrospectively evaluated 92 patients (68 men, 24 women; mean age 60.0years) who underwent liver magnetic resonance imaging (MRI) including both cDWI and sDWI. sDWI was obtained with an acceleration factor of 2. ADC values were measured from the right liver lobe, left liver lobe, spleen, pancreas, right kidney, and left kidney. ADC values of the spleen were used for normalization. Paired sample t test, Pearson's correlation coefficient, and Bland-Altman method were used for statistical analysis.ResultsADC values of cDWI were significantly lower than sDWI in all six anatomic regions (p<0.001). The mean difference in ADC value between cDWI and sDWI ranged from 0.048 to 0.125x10(-3)mm(2)/s. ADC values from cDWI and sDWI showed a moderate to very high positive correlation (p<0.001). After ADC normalization using the spleen as a reference organ, there was no significant difference between normalized ADC of cDWI and sDWI in all 5 anatomic regions (p=0.11-0.74).ConclusionsNormalization of ADC using the spleen could be useful for comparing upper abdominal organs acquired with either cDWI or sDWI in longitudinal and follow-up studies.
引用
收藏
页码:1808 / 1815
页数:8
相关论文
共 40 条
[1]   Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations [J].
不详 .
NEOPLASIA, 2009, 11 (02) :102-125
[2]   Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses [J].
Auerbach, Edward J. ;
Xu, Junqian ;
Yacoub, Essa ;
Moeller, Steen ;
Ugurbil, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) :1261-1267
[3]   Therapy response with diffusion MRI: an update [J].
Bains, Lauren J. ;
Zweifel, Martin ;
Thoeny, Harriet C. .
CANCER IMAGING, 2012, 12 (02) :395-402
[4]   Simultaneous Multislice (SMS) Imaging Techniques [J].
Barth, Markus ;
Breuer, Felix ;
Koopmans, Peter J. ;
Norris, David G. ;
Poser, Benedikt A. .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) :63-81
[5]   Diffusion-weighted imaging of the liver: an update [J].
Bharwani, N. ;
Koh, D. M. .
CANCER IMAGING, 2013, 13 (02) :171-185
[6]   Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen [J].
Braithwaite, Adam C. ;
Dale, Brian M. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
RADIOLOGY, 2009, 250 (02) :459-465
[7]   Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique [J].
Bruegel, Melanie ;
Holzapfel, Konstantin ;
Gaa, Jochen ;
Woertler, Klaus ;
Waldt, Simone ;
Kiefer, Berthold ;
Stemmer, Alto ;
Ganter, Carl ;
Rummeny, Ernst J. .
EUROPEAN RADIOLOGY, 2008, 18 (03) :477-485
[8]   Effects of gadoxetic acid on quantitative diffusion-weighted imaging of the liver [J].
Colagrande, Stefano ;
Mazzoni, Lorenzo Nicola ;
Mazzoni, Elisa ;
Pradella, Silvia .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) :365-370
[9]   Agreement and Reproducibility of Apparent Diffusion Coefficient Measurements of Dual-b-Value and Multi-b-Value Diffusion-Weighted Magnetic Resonance Imaging at 1.5 Tesla in Phantom and in Soft Tissues of the Abdomen [J].
Corona-Villalobos, Celia Pamela ;
Pan, Li ;
Halappa, Vivek Gowdra ;
Bonekamp, Susanne ;
Lorenz, Christine H. ;
Eng, John ;
Kamel, Ihab R. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) :46-51
[10]   Diagnosis of Liver Fibrosis and Cirrhosis With Diffusion-Weighted Imaging: Value of Normalized Apparent Diffusion Coefficient Using the Spleen as Reference Organ [J].
Do, Richard K. G. ;
Chandanara, Hersh ;
Felker, Ely ;
Hajdu, Cristina H. ;
Babb, James S. ;
Kim, Danny ;
Taouli, Bachir .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :671-676