The effect of lung-size mismatch on mechanical ventilation tidal volumes after bilateral lung transplantation

被引:34
作者
Dezube, Rebecca [1 ]
Arnaoutakis, George J. [2 ]
Reed, Robert M. [3 ]
Bolukbas, Servet [4 ]
Shah, Ashish S. [2 ]
Orens, Jonathan B. [1 ]
Brower, Roy G. [1 ]
Eberlein, Michael [5 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Pulm & Crit Care Med, Baltimore, MD USA
[2] Johns Hopkins Univ, Sch Med, Div Cardiac Surg, Baltimore, MD USA
[3] Univ Maryland, Sch Med, Div Pulm & Crit Care Med, Baltimore, MD 21201 USA
[4] Dr Horst Schmidt Klin, Dept Thorac Surg, Wiesbaden, Germany
[5] Univ Iowa Hosp & Clin, Div Pulm Crit Care & Occupat Med, Iowa City, IA 52242 USA
关键词
Lung transplantation; Lung-size mismatch; Mechanical ventilation; Resource utilization; RESPIRATORY-DISTRESS-SYNDROME; RANDOMIZED CONTROLLED-TRIAL; INFLAMMATORY MEDIATORS;
D O I
10.1093/icvts/ivs493
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Mechanical ventilation tidal volumes are usually set according to an estimate of patient size in millilitres (ml) per kilogram (kg) body weight. We describe the relationship between donor-recipient lung-size mismatch and postoperative mechanical ventilation tidal volumes according to recipient- and donor-predicted body weights in a cohort of bilateral lung transplant patients. A most-undersized (10 patients with lowest predicted total lung capacity [pTLC] ratio = pTLC-donor/pTLC-recipient), a most-oversized (10 patients with highest pTLC ratio) and best-matched subset (10 patients with predicted total lung capacity ratio closest to 1.0) were selected within a cohort of 70 patients. All tidal volumes during mechanical ventilation in the first 96 h after bilateral lung transplantation were recorded. Tidal volumes were expressed in ml and ml/kg-recipient-predicted body weights and ml/kg-donor-predicted body weights. Postoperative absolute tidal volumes (in ml) were comparable between subsets of patients with undersized, matched and oversized allografts (552 +/- 103 vs 581 +/- 107 vs 582 +/- 104 ml), and tidal volumes in ml/kg-recipient-predicted body weights were also similar (8.8 +/- 1.4 vs 9.3 +/- 1.1 vs 9.8 +/- 2.1). However, tidal volumes in ml/kg-donor-predicted body weights revealed significant differences between undersized, matched, and oversized subsets (11.4 +/- 3.1 vs 9.4 +/- 1.2 vs 8.1 +/- 2.1, respectively; P < 0.05). Two patients developed primary graft dysfunction grade 3, both in the undersized subset. Four patients in the undersized group underwent tracheotomy (vs none in matched and one in oversized subset). During mechanical ventilation after bilateral lung transplantation, undersized allografts received relatively higher tidal volumes compared with oversized allografts when the tidal volumes were related to donor-predicted body weights.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 9 条
[1]   Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. [J].
Brower, RG ;
Matthay, MA ;
Morris, A ;
Schoenfeld, D ;
Thompson, BT ;
Wheeler, A ;
Wiedemann, HP ;
Arroliga, AC ;
Fisher, CJ ;
Komara, JJ ;
Perez-Trepichio, P ;
Parsons, PE ;
Wolkin, R ;
Welsh, C ;
Fulkerson, WJ ;
MacIntyre, N ;
Mallatratt, L ;
Sebastian, M ;
McConnell, R ;
Wilcox, C ;
Govert, J ;
Thompson, D ;
Clemmer, T ;
Davis, R ;
Orme, J ;
Weaver, L ;
Grissom, C ;
Eskelson, M ;
Young, M ;
Gooder, V ;
McBride, K ;
Lawton, C ;
d'Hulst, J ;
Peerless, JR ;
Smith, C ;
Brownlee, J ;
Pluss, W ;
Kallet, R ;
Luce, JM ;
Gottlieb, J ;
Elmer, M ;
Girod, A ;
Park, P ;
Daniel, B ;
Gropper, M ;
Abraham, E ;
Piedalue, F ;
Glodowski, J ;
Lockrem, J ;
McIntyre, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) :1301-1308
[2]   Comparison of pulmonary function test and computed tomography volumetry in living lung donors [J].
Chen, Fengshi ;
Kubo, Takeshi ;
Shoji, Tsuyoshi ;
Fujinaga, Takuji ;
Bando, Toru ;
Date, Hiroshi .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (05) :572-575
[3]   The effect of lung size mismatch on complications and resource utilization after bilateral lung transplantation [J].
Eberlein, Michael ;
Arnaoutakis, George J. ;
Yarmus, Lonny ;
Feller-Kopman, David ;
Dezube, Rebecca ;
Chahla, Mayy F. ;
Bolukbas, Servet ;
Reed, Robert M. ;
Klesney-Tait, Julia ;
Parekh, Kalpaj R. ;
Merlo, Christian A. ;
Shah, Ashish S. ;
Orens, Jonathan B. ;
Brower, Roy G. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (05) :492-500
[4]   Ventilator settings as a risk factor for acute respiratory distress syndrome in mechanically ventilated patients [J].
Gajic, O ;
Frutos-Vivar, F ;
Esteban, A ;
Hubmayr, RD ;
Anzueto, A .
INTENSIVE CARE MEDICINE, 2005, 31 (07) :922-926
[5]   Potential for detrimental hyperinflation after lung transplantation with application of negative pleural pressure to undersized lung grafts [J].
Kozower, BD ;
Meyers, BF ;
Ciccone, AM ;
Guthrie, TJ ;
Patterson, GA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (02) :430-432
[6]   Effect of a Lung Protective Strategy for Organ Donors on Eligibility and Availability of Lungs for Transplantation A Randomized Controlled Trial [J].
Mascia, Luciana ;
Pasero, Daniela ;
Slutsky, Arthur S. ;
Jose Arguis, M. ;
Berardino, Maurizio ;
Grasso, Salvatore ;
Munari, Marina ;
Boifava, Silvia ;
Cornara, Giuseppe ;
Della Corte, Francesco ;
Vivaldi, Nicoletta ;
Malacarne, Paolo ;
Del Gaudio, Paolo ;
Livigni, Sergio ;
Zavala, Elisabeth ;
Filippini, Claudia ;
Martin, Erica L. ;
Donadio, Pier Paolo ;
Mastromauro, Ilaria ;
Ranieri, V. Marco .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 304 (23) :2620-2627
[7]   Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome - A randomized controlled trial [J].
Ranieri, VM ;
Suter, PM ;
Tortorella, C ;
De Tullio, R ;
Dayer, JM ;
Brienza, A ;
Bruno, F ;
Slutsky, AS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (01) :54-61
[8]   Revision of the 1996 working formulation for the standardization of nomenclature in the diagnosis of lung rejection [J].
Stewart, Susan ;
Fishbein, Michael C. ;
Snell, Gregory I. ;
Berry, Gerald J. ;
Boehler, Annette ;
Burke, Margaret M. ;
Glanville, Alan ;
Gould, F. Kate ;
Magro, Cynthia ;
Marboe, Charles C. ;
McNeil, Keith D. ;
Reed, Elaine F. ;
Reinsmoen, Nancy L. ;
Scott, John P. ;
Studer, Sean M. ;
Tazelaar, Henry D. ;
Wallwork, John L. ;
Westall, Glen ;
Zamora, Martin R. ;
Zeevi, Adriana ;
Yousem, Samuel A. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (12) :1229-1242
[9]   Mechanical ventilation affects inflammatory mediators in patients undergoing cardiopulmonary bypass for cardiac surgery: A randomized clinical trial [J].
Zupancich, E ;
Paparella, D ;
Turani, F ;
Munch, C ;
Rossi, A ;
Massaccesi, S ;
Ranieri, VM .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (02) :378-383