A bio-fluiclic device for adaptive sample pretreatment and its application to measurements of Escherichia coli concentrations

被引:5
作者
Choi, WJ [1 ]
Park, JK [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept BioSyst, Taejon 305701, South Korea
关键词
absorbance; adaptive dilution; bio-fluidic device; E. coli concentration; sample pretreatment; to-and-fro mixing;
D O I
10.1007/BF02931869
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this paper, we describe a bio-fluidic device for adaptive Sample pretreatment, in order to optimize the conditions under which absorbance assays can be conducted. This device can be successfully applied to the measurement of Escherichia coli (E. coli) concentrations using adaptive dilution, with which the dilution ratio can be adjusted during the dilution. Although many attempts have been previously made to miniaturize complex biochemical analyses at the chip scale, very few sample pretreatment processes have actually been miniaturized or automated at this point. Due to the lack of currently available on-chip pretreatments, analytical instruments tend to suffer from a limited range of analysis. This occasionally hinders the direct and quantitative analysis of specific analytes obtained from real samples. In order to overcome these issues, we exploit two novel strategies: dilution with a programmable ratio, and to-and-fro mixing. The bio-fluidic device consists of a rectangular chamber constructed of poly(dimethylsiloxane) (PDMS). This chamber has four openings, an inlet, an outlet, an air control, and an air vent. Each of the dilution cycles is comprised of four steps: detection, liquid drain, buffer injection, and to-and-fro mixing. When using adaptive sample pretreatment, the range in which E. coli concentrations can be measured is broadened, to an optical density (O.D.) range of 0.3 similar to 30. This device may prove useful in the on-line monitoring of cell concentrations, in both fermenter and aqueous environments.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 34 条
  • [1] Microstructure for efficient continuous flow mixing
    Bessoth, FG
    deMello, AJ
    Manz, A
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (06): : 213 - 215
  • [2] Protein sizing on a microchip
    Bousse, L
    Mouradian, S
    Minalla, A
    Yee, H
    Williams, K
    Dubrow, R
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (06) : 1207 - 1212
  • [3] CHOI OZ, 2004, P 2 INT S NAN NOV 3, P202
  • [4] Design of passive mixers utilizing microfluidic self-circulation in the mixing chamber
    Chung, YC
    Hsu, YL
    Jen, CP
    Lu, MC
    Lin, YC
    [J]. LAB ON A CHIP, 2004, 4 (01) : 70 - 77
  • [5] Fluidics and sample handling in clinical chemical analysis
    Cunningham, DD
    [J]. ANALYTICA CHIMICA ACTA, 2001, 429 (01) : 1 - 18
  • [6] Dealing with 'real' samples: sample pre-treatment in microfluidic systems
    de Mello, AJ
    Beard, N
    [J]. LAB ON A CHIP, 2003, 3 (01) : 11N - 19N
  • [7] Ekins RP, 1998, CLIN CHEM, V44, P2015
  • [8] Integrated microfluidic devices
    Erickson, D
    Li, DQ
    [J]. ANALYTICA CHIMICA ACTA, 2004, 507 (01) : 11 - 26
  • [9] Enhancement of mixing by droplet-based microfluidics
    Fowler, J
    Moon, HJ
    Kim, CJ
    [J]. FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, : 97 - 100
  • [10] EVALUATION OF PRECISION OF QUANTITATIVE MOLECULAR ABSORPTION SPECTROMETRIC MEASUREMENTS
    INGLE, JD
    CROUCH, SR
    [J]. ANALYTICAL CHEMISTRY, 1972, 44 (08) : 1375 - &