Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study

被引:16
作者
Yang, Wen Jie [1 ]
Chen, Ke Min [1 ]
Liu, Bo [2 ]
Pang, Li Fang [1 ]
Zhang, Huan [1 ]
Pan, Zi Lai [1 ]
Yan, Fu Hua [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Dept Radiol, Rui Jin Hosp, Shanghai 200025, Peoples R China
[2] Siemens Ltd, Healthcare Sect, Shanghai, Peoples R China
关键词
Coronary artery; CTA; Contrast media; ROW COMPUTED-TOMOGRAPHY; TEST BOLUS INJECTION; IODINE CONCENTRATION; DIAGNOSTIC-ACCURACY; ARTERY STENOSIS; ENHANCEMENT; NEPHROPATHY; ATTENUATION; DISEASE; WEIGHT;
D O I
10.1007/s10554-012-0068-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate the feasibility of contrast media (CM) volume reduction in dual-source coronary computed tomography angiography high-pitch mode without affecting coronary artery enhancement. Eighty patients were involved in a preliminary experiment with a default injection protocol (60 ml of CM). The age, BMI, test bolus (TB) enhancement peak and the CT values of coronary artery for each patient were recorded and the key factors for determining coronary artery enhancement were investigated. Based on the results of the preliminary experiment, 120 patients were involved in the main experiment with a new injection protocol. For each patient, the CT values and noise of left coronary sinus (LCS), and the distal segment of right coronary artery were measured. In the preliminary experiment, the peak enhancement of TB correlated most strongly with the HU values of coronary artery. Consequently, the new injection protocol was devised to catalog patients into four groups (30, 40, 50 and 60 ml) of CM based on their TB peak enhancement. In the main experiment, the 30 ml CM injection group whose peak attenuation of TB were the highest (30 vs. 40,50,60 ml: 323.0 +/- A 27.5 vs. 264.2 +/- A 11.9, 242.1 +/- A 8.8, 206.2 +/- A 18.2 HU, p < 0.05), obtained the highest attenuation of LCS (30 vs. 40,50,60 ml: 365.0 +/- A 41.2 vs. 341.8 +/- A 40.0, 326.9 +/- A 34.7, 312.5 +/- A 38.2 HU p < 0.05). Contrast optimization is feasible in high-pitch DSCT coronary angiography. Certain patients may receive 30 ml of CM without affecting vessel enhancement.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 27 条
  • [1] [Anonymous], 2006, NEPHROL DIAL TRANSPL
  • [2] Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation
    Cademartiri, F
    Mollet, NR
    van der Lugt, A
    McFadden, EP
    Stijnen, T
    de Feyter, PJ
    Krestin, GP
    [J]. RADIOLOGY, 2005, 236 (02) : 661 - 665
  • [3] High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400
    Cademartiri, F
    de Monye, C
    Pugliese, F
    Mollet, NR
    Runza, G
    van der Lugt, A
    Midiri, M
    de Feyter, PJ
    Lagalla, R
    Krestin, GP
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (03) : 349 - 353
  • [4] Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography
    Cademartiri, Filippo
    Maffei, Erica
    Palumbo, Anselmo Alessandro
    Malago, Roberto
    La Grutta, Ludovico
    Meiijboom, W. Bob
    Aldrovandi, Annachiara
    Fusaro, Michele
    Vignali, Luigi
    Menozzi, Alberto
    Brambilla, Valerio
    Coruzzi, Paolo
    Midiri, Massimo
    Kirchin, Miles A.
    Mollet, Nico R. A.
    Krestin, Gabriel P.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (03) : 576 - 583
  • [5] DEWEY M, 2009, CORONARY CT ANGIOGRA
  • [6] Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population - Comparison with conventional invasive angiography
    Ehara, M
    Surmely, JF
    Kawai, M
    Katoh, O
    Matsubara, T
    Terashima, M
    Tsuchikane, E
    Kinoshita, Y
    Suzuki, T
    Ito, T
    Takeda, Y
    Nasu, K
    Tanaka, N
    Murata, A
    Suzuki, Y
    Sato, K
    Suzuki, T
    [J]. CIRCULATION JOURNAL, 2006, 70 (05) : 564 - 571
  • [7] High-concentration contrast media in MDCT angiography: principles and rationale
    Fleischmann, D
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (Suppl 3) : N39 - N43
  • [8] Mortality associated with nephropathy after radiographic contrast exposure
    From, Aaron M.
    Bartholmai, Brian J.
    Williams, Amy W.
    Cha, Stephen S.
    Mcdonald, Furman S.
    [J]. MAYO CLINIC PROCEEDINGS, 2008, 83 (10) : 1095 - 1100
  • [9] Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis
    Garcia, Mario J.
    Lessick, Jonathan
    Hoffmann, Martin H. K.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04): : 403 - 411
  • [10] Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection
    Hittmair, K
    Fleischmann, D
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (02) : 287 - 294