Multi-criteria (thermodynamic, economic and environmental) analysis of possible design options for residential heating split systems working with low GWP refrigerants

被引:58
作者
Botticella, F. [1 ]
de Rossi, F. [1 ]
Mauro, A. W. [2 ]
Vanoli, G. P. [3 ]
Viscito, L. [2 ]
机构
[1] Univ Sannio, Dept Engn, Benevento, Italy
[2] Univ Naples Federico II, Dept Ind Engn, Ple V Tecchio 80, I-80125 Naples, Italy
[3] Univ Molise, Dept Med & Hlth Sci, Campobasso, Italy
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2018年 / 87卷
关键词
Heat pumps; Low-GWP refrigerants; Optimization; LCCP; COP; GENERAL CORRELATION; PERFORMANCE-TEST; PUMP WORKING; PROPANE; HYDROCARBONS; OPTIMIZATION; R1234YF; CHARGE; R134A; FLOW;
D O I
10.1016/j.ijrefrig.2017.10.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analysis of design configurations is proposed for a 5 kW residential space heating split system comparing several low GWP refrigerants (R32, R290, R1234yf, R1234ze, XL41, XL55) as potential alternatives to the most common refrigerants actually used (R410A, R407C, R134a). By means of an ad-hoc model, the system performance has been estimated for several geometrical configurations among those possible according to the current compressor and heat exchangers technology. The configurations complying with geometric and thermodynamic constraints are discussed in terms of opposing criteria: economic (set-up and total costs), thermodynamic (COP) and environmental ones (LCCP). With R32 it is possible to define design configurations that are able to reach the best energetic performances for fixed set-up costs. In the range of low set-up costs solutions, R32 and R410A design options are able to work with the same performance. Particularly, R32 can reach the minimum LCCP value as propane with 15% lower total costs. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:131 / 153
页数:23
相关论文
共 47 条
[21]   Pareto multi-criteria decision making [J].
Grierson, Donald E. .
ADVANCED ENGINEERING INFORMATICS, 2008, 22 (03) :371-384
[22]   A GENERAL CORRELATION FOR FLOW BOILING IN TUBES AND ANNULI [J].
GUNGOR, KE ;
WINTERTON, RHS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1986, 29 (03) :351-358
[23]  
Harada H., 2010, DYNAMIC SPECTRUM ACC, P1
[24]   Partial load performance test of residential heat pump system with low-GWP refrigerants [J].
In, Sungjin ;
Cho, Keumnam ;
Lim, Byunghan ;
Lee, Changseon .
APPLIED THERMAL ENGINEERING, 2015, 85 :179-187
[25]   Performance test of residential heat pump after partial optimization using low GWP refrigerants [J].
In, Sungjin ;
Cho, Keumnam ;
Lim, Byunghan ;
Kim, Hana ;
Youn, Baek .
APPLIED THERMAL ENGINEERING, 2014, 72 (02) :315-322
[26]  
International Energy Agency, 2010, Technical report
[27]  
International Institute of Refrigeration (IIR), 2016, 32 IIR INF NOT HARM
[28]  
Koyama S., 2010, INT REFRIGERATION AI
[29]  
Martinez-Ballester S., 2009, 5 C IB 3 C IB CIENC
[30]   Water-side reversible CO2 heat pump for residential application [J].
Minetto, Silvia ;
Cecchinato, Luca ;
Brignoli, Riccardo ;
Marinetti, Sergio ;
Rossetti, Antonio .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 63 :237-250