Head-to-head comparison of prospectively triggered vs retrospectively gated coronary computed tomography angiography: Meta-analysis of diagnostic accuracy, image quality, and radiation dose

被引:81
|
作者
Menke, Jan [1 ]
Unterberg-Buchwald, Christina [2 ]
Staab, Wieland [1 ]
Sohns, Jan Martin [1 ]
Hosseini, Ali Seif Amir [1 ]
Schwarz, Alexander [1 ]
机构
[1] Univ Hosp, Dept Diagnost Radiol, D-37075 Gottingen, Germany
[2] Univ Hosp, Dept Cardiol & Pneumol, D-37075 Gottingen, Germany
关键词
DUAL-SOURCE CT; ARTERY-DISEASE; 64-SLICE CT; CLINICAL EFFECTIVENESS; MULTIDETECTOR CT; PERFORMANCE; EXPOSURE; TESTS;
D O I
10.1016/j.ahj.2012.10.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In coronary computed tomography (CT) angiography (CTA) prospective electrocardiography triggering requires less radiation dose than retrospective electrocardiography gating but provides less cardiac phases for interpretation. This meta-analysis presents a concise and comprehensive head-to-head comparison of image quality, diagnostic accuracy, and radiation dose of prospectively triggered coronary CTA vs retrospectively gated CTA in patients with suspected or known coronary artery disease (CAD). Methods In patients with CAD and without tachyarrhythmia, eligible studies (selected from 4 databases) compared prospectively triggered vs retrospectively gated CTA (performed with >= 64-slice CT or dual-source CT) in 2 groups having approximately similar patient characteristics, scored CTA image quality, and/or assessed how accurately CTA diagnoses >= 50% coronary stenoses compared with catheter angiography and reported the radiation dose. The data were meta-analyzed by random-effects models, with CIs provided in the text. Results Among 3,330 patients from 20 included studies, 91.3% of CTAs (segments: 97.8%) had diagnostic quality with prospective triggering and 93.3% of CTAs (segments: 98.4%) with retrospective gating (P > .05). Among 664 patients from 5 studies, the pooled sensitivity/specificity of diagnostic CTAs was 98.7%/91.3% (segment level: 91.3%/97.7%) with prospective triggering and 96.9%/95.8% (segment level: 93.1%/97.6%) with retrospective gating (P > .05). The pooled effective dose was 3.5 mSv with prospective triggering and thus, by a factor of 3.5, lower than the pooled effective dose of retrospective gating, which was 12.3 mSv (P < .01). Conclusions In patients with CAD and without tachyarrhythmia, prospectively triggered coronary CTA provides image quality and diagnostic accuracy comparable with retrospectively gated CTA, but at a much lower radiation dose. (Am Heart J 2013;165:154-163.e3.)
引用
收藏
页码:154 / +
页数:13
相关论文
共 50 条
  • [1] Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography
    von Ballmoos, Moritz Wyler
    Haring, Bernhard
    Juillerat, Pascal
    Alkadhi, Hatem
    ANNALS OF INTERNAL MEDICINE, 2011, 154 (06) : 413 - +
  • [2] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    INFORMATICA, 2021, 32 (04) : 741 - 757
  • [3] Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation
    Dewey, Marc
    Zimmermann, Elke
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Schlattmann, Peter
    Knebel, Fabian
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2009, 120 (10) : 867 - 875
  • [4] Radiation dose and diagnostic accuracy of multidetector computed tomography for the detection of significant coronary artery stenoses A meta-analysis
    Pontone, Gianluca
    Andreini, Daniele
    Bartorelli, Antonio L.
    Bertella, Erika
    Mushtaq, Saima
    Annoni, Andrea
    Formenti, Alberto
    Chiappa, Luisa
    Cortinovis, Sarah
    Baggiano, Andrea
    Conte, Edoardo
    Bovis, Francesca
    Veglia, Fabrizio
    Foti, Claudia
    Ballerini, Giovanni
    Fiorentini, Cesare
    Pepi, Mauro
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 160 (03) : 155 - 164
  • [5] Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography
    Zhang, Long Jiang
    Wang, Yining
    Schoepf, U. Joseph
    Meinel, Felix G.
    Bayer, Richard R., II
    Qi, Li
    Cao, Jian
    Zhou, Chang Sheng
    Zhao, Yan E.
    Li, Xie
    Bin Gong, Jian
    Jin, Zhengyu
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 797 - 806
  • [6] Prospectively versus retrospectively ECG-gated 256-slice coronary CT angiography: image quality and radiation dose over expanded heart rates
    Hou, Yang
    Yue, Yong
    Guo, Wenli
    Feng, Guoqiang
    Yu, Tao
    Li, Guangwei
    Vembar, Mani
    Olszewski, Mark E.
    Guo, Qiyong
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01) : 153 - 162
  • [7] Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts - Comparison of Image Quality and Radiation Dose
    Lee, Yi-Wei
    Yang, Ching-Ching
    Mok, Greta S. P.
    Law, Wei-Yip
    Su, Cheng-Tau
    Wu, Tung-Hsin
    PLOS ONE, 2012, 7 (11):
  • [8] Diagnostic accuracy of coronary computed tomography angiography in ischemic workup of heart failure: a meta-analysis
    Tiwari, Nidhish
    Nagraj, Sanjana
    Tzoumas, Andreas
    Arfaras-Melainis, Angelos
    Katamreddy, Adarsh
    Sohal, Sumit
    Palaiodimos, Leonidas
    FUTURE CARDIOLOGY, 2022, 18 (04) : 325 - 335
  • [9] Diagnostic Accuracy and Radiation Dose of CT Coronary Angiography in Atrial Fibrillation: Systematic Review and Meta-Analysis
    Vorre, Mette Medom
    Abdulla, Jawdat
    RADIOLOGY, 2013, 267 (02) : 376 - 386
  • [10] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Bogaard, Kjell
    van der Zant, Friso M.
    Knol, Remco J. J.
    Reinders, Sjoerd
    Krul, Marije M. G.
    van Rossum, Albert C.
    Knaapen, Paul
    Cornel, Jan H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (01) : 125 - 133