Highly conforming polyethylene inlays reduce the in vivo variability of knee joint kinematics after total knee arthroplasty

被引:47
作者
Daniilidis, Kiriakos [4 ]
Skwara, Adrian [3 ]
Vieth, Volker [2 ]
Fuchs-Winkelmann, Susanne [3 ]
Heindel, Walter [2 ]
Stueckmann, Volker [3 ]
Tibesku, Carsten O. [1 ]
机构
[1] Sporthopaedicum Straubing, D-94315 Straubing, Germany
[2] Univ Hosp Muenster, Dept Clin Radiol, Munster, Germany
[3] Univ Hosp Marburg & Giessen, Dept Orthopaed & Rheumatol, Marburg, Germany
[4] Univ Hosp Muenster, Dept Orthopaed & Tumororthopaed, Munster, Germany
关键词
Joint replacement; Kinematics; Fluoroscopy; High conforming; Ultra congruent; Knee arthroplasty; AGE; PROPRIOCEPTION; BEARING;
D O I
10.1016/j.knee.2011.04.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of highly conforming polyethylene inlays in total knee arthroplasty (TKA) provides improved anteroposterior stability. The aim of this fluoroscopic study was to investigate the in vivo kinematics during unloaded and loaded active extension with a highly conforming inlay and a flat inlay after cruciate retaining (CR) total knee arthroplasty (TKA). Thirty one patients (50 knees) received a fixed-bearing cruciate retaining total knee arthroplasty (Genesis II, Smith & Nephew, Schenefeld, Germany) for primary knee osteoarthritis. Twenty two of them received a flat polyethylene inlay (PE), nine a deep dished PE and 19 were in the control group (physiological knees). The mean age at the time of surgery was 62 years. Dynamic examination with fluoroscopy was performed to assess the "patella tendon angle" in relation to the knee flexion angle (measure of anteroposterior translation) and the "kinematic index" (measure of reproducibility). Fluoroscopy was performed under active extension and flexion, during unloaded movement, and under full weight bearing, simulated by step climbing. No significant difference was observed between both types of polyethylene inlay designs and the physiological knee during unloaded movement. Anteroposterior (AP) instability was found during weight-bearing movement. The deep-dish inlay resulted in lower AP translation and a non-physiological rollback. Neither inlay types could restore physiological kinematics of the knee. Despite the fact that deep dished inlays reduce the AP translation, centralisation of contact pressure results in non-physiological rollback. The influence of kinematic pattern variability on clinical results warrants further investigation. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:260 / 265
页数:6
相关论文
共 20 条
[1]  
Heyse T.J., ARCH ORTHOP TRAUMA S, V130, P191
[2]   STABILIZING MECHANISMS OF LOADED AND UNLOADED KNEE-JOINT [J].
HSIEH, HH ;
WALKER, PS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) :87-93
[3]   Step length reductions in advanced age: The role of ankle and hip kinetics [J].
Judge, JO ;
Davis, RB ;
Ounpuu, S .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 1996, 51 (06) :M303-M312
[4]   AGE-RELATED-CHANGES IN PROPRIOCEPTION AND SENSATION OF JOINT POSITION [J].
KAPLAN, FS ;
NIXON, JE ;
REITZ, M ;
RINDFLEISH, L ;
TUCKER, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1985, 56 (01) :72-74
[5]   In vivo polyethylene bearing mobility is maintained in posterior stabilized total knee arthroplasty [J].
Komistek, RD ;
Dennis, DA ;
Mahfouz, MR ;
Walker, S ;
Outten, J .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :207-213
[6]   In vivo kinematics for subjects with and without an anterior cruciate ligament [J].
Komistek, RD ;
Allain, J ;
Anderson, DT ;
Dennis, DA ;
Goutallier, D .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :315-325
[7]   Comparison of proprioception in arthritic and age-matched normal knees [J].
Koralewicz, LM ;
Engh, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (11) :1582-1588
[8]  
Laskin RS, 2000, CLIN ORTHOP RELAT R, P36
[9]  
McCalden R.W., CLIN ORTHOP RELAT RE, V468, P108
[10]  
Mont MA, 2003, LNSTR COURSE LECT, V52, P397