Sensitive chemiluminescent immunoassay of triclopyr by digital image analysis

被引:8
作者
Diaz, Aurora N. [1 ]
Sanchez, Francisco G. [1 ]
Baro, Enrique N. [2 ]
Diaz, Ana F. G. [1 ]
Aguilar, Alfonso [1 ]
Algarra, Manuel [1 ]
机构
[1] Univ Malaga, Fac Ciencias, Dept Quim Analit, E-29071 Malaga, Spain
[2] Univ Malaga, Dept Ingn Comunicac, ETS Ingn Telecomunicac, E-29071 Malaga, Spain
关键词
Chemiluminescence; ELISA; Image analysis; Triclopyr; POLYSTYRENE; PROTEINS; DETECTOR; ACID;
D O I
10.1016/j.talanta.2012.03.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An image based detection of chemiluminescence enzyme-linked immunosorbent assay (CL-ELISA) for the quantification of triclopyr has been developed. The immunoassay was an indirect competitive immunoassay with an anti-rabbit secondary antibody conjugated to horseradish peroxidase (HRP). Chemiluminescence was produced by the luminol/H2O2/HRP reaction, detected by a monochrome video CCD camera and digitized with an Imagraph IC-PCI frame grabber using a custom program developed in C++ (Microsoft Visual C++ 6.0). Two main improvements are reported in the data processing software: the implementation of a circular mesh covering the perimeter of each well, eliminating diffuse light from the neighboring wells, and the use of volume (the integration of light intensity of all pixels that define a well) as an analytical signal instead of CL intensity or area (as usual in commercial plate readers) to improve precision for normalization of the total light output. The standard curve was produced for 0.01-10 ng/L triclopyr. The limit of detection was 0.8 ng/L and the variation coefficient was 3.07% (n=10, P=0.05). (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 17 条
  • [1] [Anonymous], 1998, OFF J EUR COMMUN, VL330, P32
  • [2] Digital imaging as a detector for generic analytical measurements
    Byrne, L
    Barker, J
    Pennarun-Thomas, G
    Diamond, D
    Edwards, S
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (08) : 517 - 522
  • [3] THE ADSORPTIVE CHARACTERISTICS OF PROTEINS FOR POLYSTYRENE AND THEIR SIGNIFICANCE IN SOLID-PHASE IMMUNOASSAYS
    CANTARERO, LA
    BUTLER, JE
    OSBORNE, JW
    [J]. ANALYTICAL BIOCHEMISTRY, 1980, 105 (02) : 375 - 382
  • [4] FLEEKER J, 1987, J ASSOC OFF ANA CHEM, V70, P874
  • [5] Chip-based gel electrophoresis method for the quantification of half-antibody species in IgG4 and their by- and degradation products
    Forrer, K
    Hammer, S
    Helk, B
    [J]. ANALYTICAL BIOCHEMISTRY, 2004, 334 (01) : 81 - 88
  • [6] Gonzalez R. C., 1992, DIGITAL IMAGE PROCES, V2nd
  • [7] DETERMINATION OF FREE AMINO GROUPS IN PROTEINS BY TRINITROBENZENESULFONIC ACID
    HABEEB, AFS
    [J]. ANALYTICAL BIOCHEMISTRY, 1966, 14 (03) : 328 - &
  • [8] On-chip micro-flow polystyrene bead-based immunoassay for quantitative detection of tacrolimus (FK506)
    Murakami, Y
    Endo, T
    Yamamura, S
    Nagatani, N
    Takamura, Y
    Tamiya, E
    [J]. ANALYTICAL BIOCHEMISTRY, 2004, 334 (01) : 111 - 116
  • [9] Navas Diaz A., 1996, Analytica Chimica Acta, V327, P161
  • [10] Chemiluminescent low-light imaging of biospecific reactions on macro- and microsamples using a videocamera-based luminograph
    Roda, A
    Pasini, P
    Musiani, M
    Girotti, S
    Baraldini, M
    Carrea, G
    Suozzi, A
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (07) : 1073 - 1080