Effectiveness of intermittent personalized ventilation in protecting occupant from indoor particles

被引:55
作者
Al Assaad, Douaa [1 ]
Habchi, Carine [2 ]
Ghali, Kamel [1 ]
Ghaddar, Nesreen [1 ]
机构
[1] Amer Univ Beirut, Mech Engn Dept, POB 11-0236, Beirut 11072020, Lebanon
[2] Lebanese Univ, Dept Mech Engn, Fac Engn, Branch 2, Roumieh, Lebanon
关键词
Personalized ventilation; Mixing ventilation; Intermittent ventilation; Direct contamination; Indirect contamination; THERMAL COMFORT; AIR-QUALITY; DISPLACEMENT VENTILATION; CHAIR FANS; PERFORMANCE; HEALTH; TRANSPORT; SYSTEM; ROOMS; FLOW;
D O I
10.1016/j.buildenv.2017.11.027
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, the performance of an intermittent periodic personalized ventilation (PV) coupled with mixing ventilation (MV) was investigated with respect to its ability in protecting occupant from contaminants present in the space. To perform this study, a transient 3D computational fluid dynamics (CFD) model was used to assess the velocity, temperature and particle concentration fields in the space. Experiments were performed in a climatic chamber using a thermal manikin in order to validate the CFD model's predictions of the fluid flow and particle distribution in the space at supply MV flow rate of 63 L/s and room temperature of 28 degrees C and PV average flow rate of 3.5 L/s, supply temperature of 24 degrees C, and frequencies of 0.3 Hz and 1 Hz. Good agreement was found between the CFD model and experiments. The validated model was used to recommend PV operating parameters which would assure occupant protection from macroclimate contaminants' migration to the breathing zone and microclimate surrounding the occupant, and reduce particles' deposition on the surfaces in occupant proximity. It was found that an average flowrate of 7.5 L/s as well as an operating frequency of 0.86 Hz provided acceptable values of intake fractions in the breathing zone and the surrounding microclimate as well as acceptable values of deposition rates. These conditions provide good thermal comfort levels (0.87: comfortable), and good ventilation effectiveness (77.1%).
引用
收藏
页码:22 / 32
页数:11
相关论文
共 43 条
[1]   Optimized performance of displacement ventilation aided with chair fans for comfort and indoor air quality [J].
Abou Hweij, Walid ;
Ghaddar, Nesreen ;
Ghali, Kamel ;
Habchi, Carine .
ENERGY AND BUILDINGS, 2016, 127 :907-919
[2]  
American Society of Mechanical Engineers, 2004, ASME AG 1A 2004 ADD
[3]  
Assaad D.A., 2017, ENERGY BUILD
[4]   Symptoms of wheeze and persistent cough in the first year of life: Associations with indoor allergens, air contaminants, and maternal history of asthma [J].
Belanger, K ;
Beckett, W ;
Triche, E ;
Bracken, MB ;
Holford, T ;
Ren, P ;
McSharry, JE ;
Gold, DR ;
Platts-Mills, TAE ;
Leaderer, BP .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2003, 158 (03) :195-202
[5]   The health effects of nonindustrial indoor air pollution [J].
Bernstein, Jonathan A. ;
Alexis, Neil ;
Bacchus, Hyacinth ;
Bernstein, I. Leonard ;
Fritz, Pat ;
Horner, Elliot ;
Li, Ning ;
Mason, Stephany ;
Nel, Andre ;
Oullette, John ;
Reijula, Kari ;
Reponen, Tina ;
Seltzer, James ;
Smith, Alisa ;
Tarlo, Susan M. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (03) :585-591
[6]   The Regional Particulate Matter Model .1. Model description and preliminary results [J].
Binkowski, FS ;
Shankar, U .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1995, 100 (D12) :26191-26209
[7]   Methods for air cleaning and protection of building occupants from airborne pathogens [J].
Bolashikov, Z. D. ;
Melikov, A. K. .
BUILDING AND ENVIRONMENT, 2009, 44 (07) :1378-1385
[8]   Air pollution and cardiovascular disease - A statement for healthcare professionals from the expert panel on population and prevention science of the American Heart Association [J].
Brook, RD ;
Franklin, B ;
Cascio, W ;
Hong, YL ;
Howard, G ;
Lipsett, M ;
Luepker, R ;
Mittleman, M ;
Samet, J ;
Smith, SC ;
Tager, I .
CIRCULATION, 2004, 109 (21) :2655-2671
[9]   Performance of personalized ventilation in conjunction with mixing and displacement ventilation [J].
Cermak, R ;
Melikov, AK ;
Forejt, L ;
Kovar, O .
HVAC&R RESEARCH, 2006, 12 (02) :295-311
[10]   Protection of occupants from exhaled infectious agents and floor material emissions in rooms with personalized and underfloor ventilation [J].
Cermak, Radim ;
Melikov, Arsen K. .
HVAC&R RESEARCH, 2007, 13 (01) :23-38